Engineering Papers⌕ Search

Engineering topics

Essex, Richard M.

Publications and source records attributed to Essex, Richard M..

New reference materials for trace-levels of actinide elements in plutonium

In this report two plutonium oxides were prepared as unique reference materials for measurement of actinide elements present as trace constituents. Each reference material unit is approximately 200 mg of PuO 2 powder in a quartz glass bottle. Characterized attributes of the oxides included mass fractions of plutonium, americium, neptunium, and uranium. Isotope-amount ratios were also determined for plutonium and uranium, but neptunium and americium were observed to be monoisotopic 237 Np and 241 Am. Measurements for characterization and verification of the attributes show that plutonium and trace actinides are homogeneous with the exception of limited heterogeneity for uranium, primarily observed for the 238 U isotope. Model purification ages calculated from measured americium and uranium attribute values are consistent with material histories and indicate that these impurities are predominantly due to the decay of plutonium isotopes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A new highly enriched 233 U reference material for improved simultaneous determination of uranium amount and isotope amount ratios in trace level samples

A highly-enriched 233 U reference material (>0.99987 n( 233 U)/n(U)) has been prepared and characterized for use as an isotope dilution mass spectrometry spike. An ion exchange separation was performed on 1 g of high purity 233 U to further reduce trace amounts of contaminant Pu in the material. The purified 233 U was then prepared as a master solution which was analyzed for molality of uranium by modified Davies and Gray titration. A portion of the master solution was quantitatively diluted and dispensed for reference material units. Selected units were analyzed for verification of uranium amount and to characterize uranium isotope amount ratios by multi-collector inductively couple plasma mass spectrometry. Furthermore, modelling of spike-corrected isotopic data show that the new spike will enable simultaneous measurements of uranium amount and isotope amount ratios with resulting uncertainties that are substantially less sensitive to over spiking than widely used 233 U certified reference materials.

233U↗

A highly-enriched 244 Pu reference material for nuclear safeguards and nuclear forensics measurements

A highly-enriched 244 Pu isotope dilution reference material has been prepared and characterized for metrologically traceable measurements of very small quantities of plutonium. The amount of plutonium in samples associated with nuclear safeguards and nuclear forensic measurements can be significantly less than 1 ng. Accordingly, the ability to quantify the amount and isotopic composition of plutonium from a single mass-spectrometric analysis is particularly desirable. The highly-enriched 244 Pu reference material, described here, will minimize the magnitude of spike corrections necessary to obtain accurate information on plutonium isotopic composition from isotope dilution measurements.

07 ISOTOPE AND RADIATION SOURCES↗

Preparation and calibration of a 231 Pa reference material

A 231 Pa reference material has been characterized for amount of protactinium. This reference material is primarily intended for calibration of 233 Pa tracers produced for 235 U– 231 Pa model age measurements associated with nuclear forensics and nuclear safeguards. Primary measurements for characterization were made by isotope dilution mass spectrometry of a purified 231 Pa solution using a 233 Pa isotopic spike. The spike was calibrated by allowing multiple aliquots of the 233 Pa spike solution to decay to 233 U and then measuring the ingrown 233 U by isotope dilution mass spectrometry using a certified uranium assay and isotopic standard as a reverse-spike. In conclusion, the new 231 Pa reference material will simplify calibration of the 233 Pa isotope dilution spikes, provide metrological traceability, and potentially reduce the overall measurement uncertainty of model ages.

231Pa↗

Trace impurity analysis in uranium oxide via hybrid quantification techniques—gravimetric standard addition and isotope dilution mass spectrometry

Measurement methods for the analysis of trace impurities in uranium materials, essential in nuclear fuel production and nuclear forensics, are continuously improving. Analytical methods were developed with the goal of lowering uncertainties of next generation certified uranium oxide reference materials for trace impurity concentrations. Through addition of a traceable standard directly into the sample, gravimetric standard addition and isotope dilution followed by analysis on an inductively coupled plasma mass spectrometer can achieve lower uncertainties. In conclusion, results for 28 impurities in CRM 124-1 and 124-6 from NBL Program Office were used for validation of accuracy and comparisons of uncertainties.

36 MATERIALS SCIENCE↗

New determination of the 229 Th half-life

A new determination of the 229 Th half-life was made based on measurements of the 229 Th massic activity of a high-purity solution for which the 229 Th molality had previously been measured. The 229 Th massic activity was measured by direct comparison with SRM 4328C using 4παβ liquid scintillation counting, NaI counting, and standard addition liquid scintillation counting. The 229Th massic activity was confirmed by isotope dilution alpha spectrometry measurements. The 229 Th half-life calculated from the activity measurements is (7825 ± 87) years (k = 2).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new thorium-229 reference material

A new reference material was characterized for 229 Th molality and thorium isotope amount ratios. This reference material is intended for use in nuclear forensic analyses as an isotope dilution mass spectrometry spike. The reference material value and expanded uncertainty (k = 2) for the 229 Th molality is (1.1498 ± 0.0016)×10 -10 mol g -1 solution. The value and expanded uncertainty (k = 2) for the n( 230 Th)/n( 229 Th) ratio is (5.18 ± 0.26)×10 -5 and the n( 232 Th)/n( 229 Th) ratio is (3.815 ± 0.092)×10 -4 .

07 ISOTOPE AND RADIATION SOURCES↗