Engineering Papers⌕ Search

Engineering topics

Espy, Michelle A.

Publications and source records attributed to Espy, Michelle A..

At least 19 records

Benefits of symbiotic ectomycorrhizal fungi to plant water relations depend on plant genotype in pinyon pine

Rhizosphere microbes, such as root-associated fungi, can improve plant access to soil resources, affecting plant health, productivity, and stress tolerance. While mycorrhizal associations are ubiquitous, plant–microbe interactions can be species specific. Here we show that the specificity of the effects of microbial symbionts on plant function can go beyond species level: colonization of roots by ectomycorrhizal fungi (EMF) of the genus Geopora has opposite effects on water uptake, and stomatal control of desiccation in drought tolerant and intolerant genotypes of pinyon pine (Pinus edulis Engelm.). These results demonstrate, for the first time, that microorganisms can have significant and opposite effects on important plant functional traits like stomatal control of desiccation that are associated with differential mortality and growth in nature. They also highlight that appropriate pairing of plant genotypes and microbial associates will be important for mitigating climate change impacts on vegetation.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Coronado State Historic Site artifacts using X-rays

Two historic-period metal artifacts were provided by the New Mexico Historic Sites to Los Alamos National Laboratory for non-destructive analysis. The artifacts were a crossbow quarrel (or bolthead) and a reliquary pendant recovered from Kuaua Pueblo (also known as the Coronado Historic Site) in Bernalillo, NM. The quarrel is a heavily patinated metal that had been flattened due to compressive forces. The pendant consisted of a metal casing that had previously surrounded two center gemstones on the front and rear face of the pendant. The gemstone in the rear setting had fractured and was displaced from the setting, leaving only a small, loose fragment within the pendant for study. The front gem appeared to be very dark, near-black in color, and the fragment of the rear gem was a bright red color. The artifacts were analyzed to ascertain their composition and glean insight into their provenance using the following X-ray techniques: X-ray computed tomography, confocal micro X-ray fluorescence, and X-ray diffraction. Infrared spectroscopy and electron microscopy were used on selected areas. Ultraviolet Raman spectra were collected on the two gems and the pendant. The metal material of the artifacts was found to be primarily composed of copper. The gems in the pendant were composed of manganese (front gem) and calcium (side gem).

36 MATERIALS SCIENCE↗

Methods and systems for J-coupled nuclear magnetic resonance

A nuclear magnetic resonance (NMR) system is configured to detect combinatorial signatures stemming from homonuclear and heteronuclear J-couplings. The system comprises a pre-polarization system, a detector, and NMR electronics, wherein the detector includes an NMR magnet with a magnetic field of strength between 300 mT and 10 μT.

Williams, Robert F.↗

Two bright, optically clear, intrinsic fast-neutron and charged-particle detector materials for neutron imaging and other applications

Two optically clear, bright, scintillating ZnS materials have been identified that, like previous opaque ZnS scintillators, are excellent charged particle detectors. We show that ZnS is a good fast-neutron-to charged-particle converter making optically clear ZnS an intrinsic fast-neutron detector that does not require layering or mixing of converter materials and scintillator materials, and removes the limitations imposed by opaque ZnS scintillator materials used for more than a century. Thermal neutron detection using optically clear 6 LiF or 10 BN and clear ZnS may benefit from improved spatial resolution and light transmission. Properties and tests of clear scintillating ZnS are described. Fast-neutron imaging applications benefit from increased efficiency of these scintillators, minimal scattering in the scintillator, and increased useful detector volume. Charged particle and fast-neutron detectors have numerous applications in nuclear non-proliferation and security, nuclear and particle physics, and non-destructive testing and environmental measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods and systems for low to ultra-low magnetic field nuclear magnetic resonance for detecting chemical nerve agents

A nuclear magnetic resonance (NMR) system is configured to detect chemical threat material. The system comprises a magnet configured to generate a magnetic field of about 300 millitesla or less; and a probe configured to detect nuclear relaxation of at least two nuclei selected from the group consisting of 1H, 19F, 31P and 14N, and detect the spin density of nuclei selected from the group consisting of 1H, 19F, 31P and 14N, following excitation.

Williams, Robert F.↗

High Fidelity Tomographic Density Reconstructions [Slides]

Pressed high explosives have small density variations associated with the pressing process, from a few to sub percent depending on the material. Variations at these levels are known to have an impact on HE performance. Currently, a destructive testing method based on physical sectioning followed by immersion density measurements (slice and dice) is utilized. However, this method has poor spatial resolution limited by the the sectioning size, 1-2 cm. If possible, radiographic methods including Computed Tomography (CT) would be preferred, as they are non-destructive and have higher (less than .1 mm) spatial resolution. However, beam hardening, scattered radiation, and detector effects make density reconstructions at this level extremely challenging.

42 ENGINEERING↗

Gold leaf phantom development for the assessment of proton radiographic sensitivity limits simulating gold nanoparticle tagged tumors

Proton radiography may guide proton therapy cancer treatments with beam’s-eye-view anatomical images and a proton-based estimation of proton stopping power. However, without contrast enhancement, proton radiography will not be able to distinguish tumor from tissue. To provide this contrast, functionalized, high-Z nanoparticles that specifically target a tumor could be injected into a patient before imaging. We conducted this study to understand the ability of gold, as a high-Z, biologically compatible tracer, to differentiate tumors from surrounding tissue. We indicate that AuNP-enhanced proton radiography might be a feasible technology to provide image-guidance to proton therapy, potentially reducing off-target effects and sparing nearby tissue. These data can be used to develop treatment plans and clinical applications can be derived from the simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spectral characterization of flash and high flux x-ray radiographic sources with a magnetic Compton spectrometer

In this article, we present a new analysis method applied to revitalize permanent magnet Compton spectrometers used to measure photon energy spectra in the MeV range. The inversion of the measured electron distribution to determine the original photon distribution is achieved via a method of consistent coupled radiation transport and magnetic field mapping of the input photon spectra to the measured electron distribution. The method of linear least squares was used to perform the unfolding of the electron distribution to the initial photon spectra, without any assumptions made regarding the electron distribution. We present an application of this method to data from a nominal 19.4 MeV flash radiographic source (the first axis of the Dual Axis Radiographic Hydro-Test Facility) capable of generating 500 R @ 1 m in ~60 ns and a medical therapy source (a Scanditronix M22, Microtron) capable of variable energies with nominal endpoints of 6, 10, 15, and 20 MeV and an output of ~1000–2000 R/min @ 1 m. The results provide agreement between the modeled and unfolded experimentally measured photon spectra as quantified by statistical tests, from 1.5 to 20 MeV. Experimental results are presented as well as a discussion of the novel MCNP6-based simulations and methods for reconstruction of the spectra.

47 OTHER INSTRUMENTATION↗

Limited-view Cone Beam CT reconstruction using 3D Patch-based Supervised and Adversarial Learning [Slides]

We present a novel machine learning CNN architecture that can learn from limited data combined appropriately with physics and statistical priors (e.g., forward models and noise models). To address the limited availability of training data we adopt a 3D patch-based approach for our models. Patch-based learning is central to several image reconstruction methods and demands fewer training data than DL approaches, as a single data volume can be broken into several millions of overlapping 3D sub-volumes or patches. This creates a very large number of training sub-volumes from a limited number of overall image volumes. A 3D Generative Adversarial Networks (GAN) is then trained to remove artifacts at the sub-volume level. The combination of a sub-volume-based approach with DL allows us to exploit the richness of the latter in extracting and representing image features, while avoiding risks associated with overfitting due to limited training data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The 1 H T 1 dispersion curve of fentanyl citrate to identify NQR parameters

We report the 1 H T 1 dispersion curve between 0 and 5 MHz for the synthetic opioid fentanyl citrate (C 28 H 36 N 2 O 8 ). The structures in the curve can be used to estimate the 14 N nuclear quadrupole resonance (NQR) frequencies of the material. Density functional theory predictions of the NQR parameters of several fentanyl citrate compounds are also reported. The predictions for the aniline nitrogen are consistent with structures in the observed T 1 data. To help interpret the fentanyl citrate results the T 1 dispersion curve for the explosive ammonium nitrate is also presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dark field proton radiography

A pre- and post-collimation scheme has been applied to high energy proton radiography to establish a dark field condition, which defaults to a state of no transmission until a scatterer is placed at the object plane. This technique, dark field proton radiography, provides two additional capabilities to a standard proton radiography setup. First, protons with a high degree of angular dispersion are removed from the beam, reducing the effects of chromatic aberrations and decreasing noise. Second, protons below the same threshold are removed from the beam downstream of the objects, effectively making the transmission highly sensitive to small amounts of scatter at the object plane. Finally, initial results indicate that the system is highly sensitive to the presence of thinner materials and improves sensitivity to subtle areal density variations in thick objects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Summary of Results for Idaho Accelerator Center (IAC) Experiments with Compact Electron Permanent Magnet Spectrometer (CEPMS)

The Compact Electron Permanent Magnet Spectrometer (CEPMS) shown in Figure 2 consists of collimation at the electron beam entrance, a vacuum chamber for beam transport and a removable 60 degree sector magnet constructed by SABR Enterprises (Ref 2) that is used to momentum analyze the incoming electron beam. There are electron detection planes located perpendicular to straight through and the 60 degree trajectory ports. The planes are designed to accept phosphor screens for time integrated measurements. The screens can be replaced by scintillator for time resolved measurements using gated or streak cameras. The length of the spectrometer along the beamline without the collimator is about 400mm (14”). The spectrometer requires no power supply with controls for cycling or cooling for the magnet. The entire assembly, with magnet installed, weighs about 35kg (75lbs) Figure 3 depicts central and extreme trajectories through the spectrometer for various electron energies. The chamber accommodates a +/-50mm wide detection field relative to the center trajectory. Trajectories with larger momentum (energy) are bent the least. Since the permanent magnet slides off and on with reference to the upstream edge of the vacuum chamber, it can be adjusted to various positions to slightly increase or decrease the central energy thereby changing the range of available energies. Figure 4 shows the effect of changing the location of the permanent magnet on the electron trajectory. A small inward change in r produces a longer trajectory in the magnet therefore, the same energy trajectory is bent more.

43 PARTICLE ACCELERATORS↗

(U) PRAD0697 & PRAD0698: Complex Loading of CeO₂ Powder

Cerium(IV) oxide (CeO₂) powder is shock compressed using the Precision High Energy-density Liner Implosion eXperiment (PHELIX) platform. Experimental results are compared against several modeling approaches. Compaction behavior is best captured with a P-∝ model, which calculates CeO₂ powder bulk densities within 80-99% of experimental values but overpredicts densi cation at the cylindrical target's outer radius and center by up to 20%. Preliminary calculations suggest that accuracy could be increased with the inclusion of a coupled strength model. Several common computational modeling approaches for the shock compression response of granular materials and the magnetohydrodynamic (MHD) force upon the impactor/liner in pulsed power compression experiments are investigated and analyzed for their validity. The Bi-linear Ramp, P-∝ PACXP, and P-∝ Menikoff-Kober continuum compaction models are calibrated to planar impact Hugoniot data for CeO₂ powder and used to predict the powder's shock compaction response under non-planar shock wave compression. MHD calculations of the PHELIX pulsed power driver are performed using an idealized resistor-inductor-capacitor (RLC) circuit calibrated to previous experiments. All simulations are performed using the LANL code FLAG. Two validation experiments are computationally designed using the calibrated compaction and circuit models, executed using the PHELIX platform on CeO₂ targets with initial porous densities of 3.95 and 4.03 g/cm³, measured with proton radiography, and analyzed against the model predictions. The two P-∝ models more accurately describe CeO₂ powder densi cation than the Bi-linear Ramp model. However, the two P-∝ models overpredict bulk density of the shock compressed CeO₂ powder by up to 20% when the appropriate impact velocities are applied. MHD calculations for both validation experiments underpredict liner impact velocities by 4-11% when using the idealized RLC circuit model calibrated to previous experiments. Compensating underpredictions of impact velocity and overpredictions of powder densication lead to a false accuracy in pre-shot calculations compared to experimental data. To improve correlation between simulations and experiments, the following improvements are suggested: 1. A coupled strength model for CeO₂ powder that updates strength as a function of porosity and applied stress. 2. An improved MHD circuit model that more accurately captures the PHELIX machine.

36 MATERIALS SCIENCE↗

Chemical Analysis of Fluorobenzenes via Multinuclear Detection in the Strong Heteronuclear J-Coupling Regime

Chemical analysis via nuclear magnetic resonance (NMR) spectroscopy using permanent magnets, rather than superconducting magnets, is a rapidly developing field. Performing the NMR measurement in the strong heteronuclear J-coupling regime has shown considerable promise for the chemical analysis of small molecules. Typically, the condition for the strong heteronuclear J-coupling regime is satisfied at µT magnetic field strengths and enables high resolution J-coupled spectra (JCS) to be acquired. However, the JCS response to systematic chemical structural changes has largely not been investigated. In this report, we investigate the JCS of C6H6−xFx (x = 0, 1, 2, …, 6) fluorobenzene compounds via simultaneous excitation and detection of 19F and 1H at 51.5 µT. The results demonstrate that JCS are quantitative, and the common NMR observables, including Larmor frequency, heteronuclear and homonuclear J-couplings, relative signs of the J-coupling, chemical shift, and relaxation, are all measurable and are differentiable between molecules at low magnetic fields. The results, corroborated by ab initio calculations, provide new insights into the impact of chemical structure and their corresponding spin systems on JCS. In several instances, the JCS provided more chemical information than traditional high field NMR, demonstrating that JCS can be used for robust chemical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗