Investigation of ground effects on large and small scale models of a three fan V/STOL aircraft configuration

Induced lift of a subsonic, three fan, lift/cruise, V/STOL aircraft configuration was investigated using scale modes of a multimission aircraft whose design incorporates a nose mounted lift fan and two lift/cruise units located over the wing. Configuration effects were assessed for lift improvement devices, lift/cruise nozzle rails, nozzle perimeter plates, and alternate nose fan exit hubs. Tests were conducted at four model heights (H/D = 0.95, 1.53, 3.06 and 6.45, where D is the average nozzle exit diameter equal to 0.997 m.) Results are presented and discussed.

Schuster, E. P.↗

Thrust and mass flow characteristics of four 36 inch diameter tip turbine fan thrust vectoring systems in and out of ground effect

The calibration tests carried out on the propulsion system components of a 70 percent scale, powered model of a NASA 3-fan V/STOL aircraft configuration are described. The three X3/6B/T58 turbotip fan units used in the large scale powered model were tested on an isolated basis over a range of ground heights from H/D of 1.02 to infinity. A higher pressure ratio LF336/J85 fan unit was tested over a range of ground heights from 1.55 to infinity. The results of the test program demonstrated that: (1) the thrust and mass flow performance of the X376B/T58 nose lift unit is essentially constant for H/D variations down to 1.55; at H/D 1.02 back pressurization of the fan exit occurs and is accompanied by an increase in thrust of five percent; (2) a change in nose fan exit hub shape from flat plate to hemispherical produces no significant difference in louvered lift nozzle performance for height variations from H/D = 1.02 to infinity; (3) operation of the nose lift nozzle at the higher fan pressure ratio generated by the LF336/J85 fan system causes no significant change in ground proximity performance down to an H/D of 1.55, the lowest height tested with this unit; and (4) the performance of the left and right X376B/T58 lift/cruise units in the vertical lift mode remains unchanged, within plus or minus two percent for the range of ground heights from H/D = 1.02 to infinity.

Esker, D. W.↗

Ground test of the D shaped vented thrust vectoring nozzle

Static ground tests of a large scale lift/cruise thrust vectoring nozzle were conducted to establish: (1) vectoring performance 'in' and 'out' of ground effect; (2) thrust spoilage capability; (3) compatibility of the nozzle with a turbotip fan; and (4) the nozzle structural temperature distribution. Vectoring performance of a short coupled, vented nozzle design on a large scale, (60%) basis was compared with small scale (4.5%) test nozzle results. The test nozzle was a "boilerplate" model of the MCAIR "D" vented nozzle configured for operation with the LF336/J85 turbotip lift fan system. Calibration of the LF336/J85 test fan with a simple convergent nozzle was performed with four different nozzle exit areas to establish reference thrust, nozzle pressure ratio, and nozzle corrected flow characteristics for comparison with the thrust vectoring nozzle data. Thrust vectoring tests with the 'D' vented nozzle were conducted over the range of vector angles between 0 and 117 deg for several different nozzle exit areas.

Esker, D. W.↗

Vented vectoring-nozzle for STOL and V/STOL aircraft

Vented vectoring-nozzle has superior thrust coefficient and is lighter in weight because it does not require completely enclosed elbow duct ordinarily used to deflect nozzle flow. Improved nozzle has primary nozzle and three-sided elbow deflector.