Engineering PapersSearch

Engineering topics

Erickson, J. C., Jr.

Publications and source records attributed to Erickson, J. C., Jr..

Streamlining algorithms for complete adaptation

For purposes of the adaptive-wall algorithms to be described, the modern era is considered to have begun with the simultaneous, independent recognition of the concept of matching an experimental inner flow across an interface to a computed outer flow by Chevallier, Ferri, Goodyer, Lissaman, Rubbert, and Sears. Fundamental investigations of the adaptive-wall matching concept by means of numerical simulations and theoretical considerations are described. An overview of the development and operation of 2D adaptive-wall facilities from about 1970 until the present is given, followed by similar material for 3D adaptive-wall facilities from approximately 1978 until the present. A general formulation of adaptation strategy is presented, with a theoretical basis for adaptation followed by 2D flexible, impermeable-wall applications; 2D ventilated-wall applications; 3D flexible, impermeable-wall applications; and 3D ventilated-wall applications. Representative experimental and 3D results are given, with 2D, followed by a discussion of limitations and open questions.

Erickson, J. C., Jr.

Limits of adaptation, residual interferences

Methods of determining linear residual wall interference appear to be well established theoretically; however they need to be validated, for example by comparative studies of test data on the same model in different adaptive-wall wind tunnels as well as in passive, ventilated-wall tunnels. The GARTEur CAST 7 and the CAST 10/DOA 2 investigations are excellent examples of such comparative studies. Results to date in both one-variable and two-variable methods for nonlinear wall interference indicate that a great deal more research and validation are required. The status in 2D flow is advanced over that in 3D flow as is the case generally with adaptive-wall development. Nevertheless, it is now well established that for transonic testing with extensive supercritical flow present, significant wall interference is likely to exist in conventional ventilated test sections. Consequently, residual correction procedures require further development hand-in-hand with further adaptive-wall development.

Mokry, Miroslav

Research on self-correcting wind tunnels

The Calspan self-correcting wind tunnel is a two-dimensional facility in which the flow field in the vicinity of the walls is actively controlled, and a theoretical evaluation is used in conjunction with flow field measurements to confirm that wall interference was minimized. The facility is described, and the results of experiments with a 6 percent-blockage model are presented to show that iterative application of wall control effectively eliminates the interference. Experiments were performed at conditions where the flow at the walls was supercritical, and a new operating procedure is described for these conditions. The results of an analysis of the flow in the auxiliary suction system and test ion illustrate the tradeoffs available in the design of self-correcting wind tunnel test sections and in model sizing for such tunnels.

Vidal, R. J.

Interference-free wind-tunnel flows by adaptive-wall technology

The adaptive-wall or self-correcting wind tunnel has been proposed for such regimes as transonic and V/STOL where wall effects are large and cannot be corrected for. The power and generality of the concept are pointed out. In a two-dimensional transonic embodiment in the Calspan One-Foot Tunnel, the scheme has been shown to work at lower transonic Mach numbers. Several practical problems are cited, including instrumentation, the nature of the wall modification, and convergence of the iterative procedure. Moreover, questions of shock-wave neutralization at the wall and probable configuration of three-dimensional embodiments are discussed.

Sears, W. R.

Application of the adaptive-wall concept to three-dimensional low-speed wind tunnels

Three methods for evaluating the functional relationships required to obtain interference-free flows about a model in a wind tunnel have been developed. The first, the original multipole expansion (MPE) procedure, is based on a series of point singularities which satisfy the governing Prandtl-Glauert equation. The second, the modified MPE, provides an improved representation of finite-span wings and thereby extends the range of validity of the original MPE to larger ratios of span-to-control-surface-width. The third method is more general and is based on source distributions over the control surface. Several numerical examples are presented to help establish the range of validity of these methods. An accuracy-assessment procedure, which combines the original MPE procedure with classical wall-correction theory, has been developed to estimate the degree of interference at the model if the functional relationships are not satisfied exactly. Several numerical examples are presented for representative wings and bodies.

Erickson, J. C., Jr.

Experiments with a self-correcting wind tunnel

The feasibility of controlling the flow actively through the walls of a transonic, porous wall wind tunnel in order to minimize wall interference effects on a test model is demonstrated. The method is based upon measuring the components of the disturbance velocity at discrete points along an imaginary surface in the flow field within the tunnel. A mathematical formulation of the flow field exterior to the surface including the boundary condition for unconfined flow, i.e., that all disturbance vanish at infinite, is used to determine if these measured velocity components are consistent with that boundary condition. If they are not, the theory provides a better approximation to the velocity component for unconfined flow, and the flow through the tunnel walls is readjusted iteratively until the measured quantities are consistent with unconfined flow. A brief review of theoretical methods is followed by a description of the Calspan self correcting wind tunnel design and operation, calibration with and without active wall control. Typical results obtained by approximating a conventional porous wall wind tunnel for an 0012 airfoil show that active wall control largely reproduces the correct shock wave position, eliminates wall interference of lift and drag, and reduces the interference effects on pitching moment to 10%.

Vidal, R. J.

On the transonic aerodynamics of a compressor blade row

Linearized analyses have been carried out for the induced velocity and pressure fields within a compressor blade row operating in an infinite annulus at transonic Mach numbers of the flow relative to the blades. In addition, the relationship between the induced velocity and the shape of the mean blade surface has been determined. A computational scheme has been developed for evaluating the blade mean surface ordinates and surface pressure distributions. The separation of the effects of a specified blade thickness distribution from the effects of a specified distribution of the blade lift has been established. In this way, blade mean surface shapes that are necessary for the blades to be locally nonlifting have been computed and are presented for two examples of blades with biconvex parabolic arc sections of radially tapering thickness. Blade shapes that are required to achieve a zero thickness, uniform chordwise loading, constant work spanwise loading are also presented for two examples. In addition, corresponding surface pressure distributions are given. The flow relative to the blade tips has a high subsonic Mach number in the examples that have been computed. The results suggest that at near-sonic relative tip speeds the effective blade shape is dominated by the thickness distribution, with the lift distribution playing only a minor role.

Erickson, J. C., Jr.