Engineering Papers⌕ Search

Engineering topics

Eremeev, Grigory

Publications and source records attributed to Eremeev, Grigory.

51 records · Page 3

Nb3Sn SRF Cavities for Nuclear Physics Applications

Nuclear physics experiments rely increasingly on accelerators, which employ superconducting RF (SRF) technology. CEBAF, SNS, FRIB, ESS, among others exploit the low surface resistance of SRF cavities to efficiently accelerate particle beams towards experimental targets. Niobium is the cavity material of choice for all current or planned SRF accelerators, but it has been long recognized that other superconductors with high superconducting transition temperatures have the potential to surpass niobium for SRF applications. Among the alternatives, Nb3Sn coated cavities are the most advanced on the path to practical applications: Nb3Sn coatings on R&D cavities have Tc consistently close the optimal 18 K, very low RF surface resistances, and very recently were shown to reach above Hc1 without anomalous RF surface resistance increase. In my talk I will discuss the prospects of Nb3Sn SRF cavities and the research efforts to realize Nb3Sn coatings on practical multi-cell accelerating structures.

Eremeev, Grigory↗

4 K SRF Operation of the 10 MeV CEBAF Photo-Injector

Superconducting radio-frequency (SRF) accelerating cavities are often operated in superfluid liquid helium with temperature near 2 K to enhance the cavity quality factor Q0 and to help manage heat loads, which are particularly important at large SRF accelerator facilities. This 2 K temperature paradigm, however, need not put SRF technology out of the reach of small institutions or even limit SRF operation at large facilities that need 10-100 MeV beam energy. At the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab there are regularly scheduled maintenance periods during which cryogenic plant often increases the liquid helium temperature from 2 K to 4 K, reducing power consumption by ~ 50 % and saving megawatts of wall-plug power. During recent maintenance periods, we accelerated a continuous-wave electron beam at the CEBAF photo-injector to a total energy of 6.3 MeV at currents up to 80 uA using two 5-cell niobium cavities in the quarter-cryomodule at 4 K. This contribution describes the SRF and cryogenic performance and uses measured beam quality and energy stability as key metrics. These measurements indicate that 4 K operation of niobium SRF cavities in CEBAF is a sensible and cost effective mode for high quality beam operation, provided the cryogenic load associated with lower Q0 is manageable for the number of cavities needed to operate. For Jefferson Lab, this enhances our scientific reach allowing additional low-energy ~ 10 MeV experiments each year.

Drury, Michael↗

Experimental Study of Nucleation for Nb3Sn Diffusion Coatings on Niobium SRF cavities

Nb3Sn has the potential to achieve superior performance both in terms quality factor and accelerating gradient resulting in significant reduction in both initial and operating costs of SRF linacs. Cavity interior surface coatings are obtained by two-step vapor diffusion: nucleation followed by deposition. To gain more understanding of nucleation and its effect on the subsequent coating, we investigated the effect of varying parameters in a typical tin/tin chloride process. We report findings obtained by SEM/EDS, AFM, SAM and other materials characterization approaches.

Pudasaini, Uttar↗

Commissioning results of Nb 3 Sn cavity vapor diffusion deposition system at JLab

Nb 3 Sn as a BCS superconductor with a superconducting critical temperature higher than that of niobium offers potential benefit for SRF cavities via a lower-than-niobium surface resistance at the same temperature and frequency. A Nb 3 Sn vapor diffusion deposition system designed for coating of 1.5 and 1.3 GHz single-cell cavities was built and commissioned at JLab. As the part of the commissioning, RF performance at 2.0 K of a single-cell 1.5 GHz CEBAF-shaped cavity was measured before and after coating in the system. Before Nb 3 Sn coating the cavity had a Q 0 of about 10 10 and was limited by the high field Q-slope at E acc ≅ 27 MV/m. Coated cavity exhibited the superconducting transition at about 17.9 K. The low-field quality factor was about 5∙10 9 at 4.3 K and 7∙10 9 at 2.0 K decreasing with field to about 1∙10 9 at E acc ≅ 8 MV/m at both temperatures. The highest field was limited by the available RF power.

36 MATERIALS SCIENCE↗

Quench Studies of Six High Temperature Nitrogen Doped 9 Cell Cavities for Use in the LCLS-II Baseline Prototype Cryomodule at Jefferson Laboratory

Jefferson Lab (JLab) processed six nine-cell cavities as part of a small-scale production for LCLS-II cavity processing development utilizing the promising nitrogen-doping process. Various nitrogen-doping recipes have been scrutinized to optimize process parameters with the aim to guarantee an unloaded quality factor (Q_0) of 2.7∙10 10 at an accelerating field (Eacc) of 16 MV/m at 2.0 K in the cryomodule. During the R&D phase the characteristic Q0 vs. Eacc performance curve of the cavities has been measured in JLab’s vertical test area at 2 K. The findings showed the characteristic rise of the Q0 with Eacc as expected from nitrogen-doping. Initially, five cavities achieved an average Q0 of 3.3·10 10 at the limiting Eacc averaging to 16.8 MV/m, while one cavity experienced an early quench accompanied by an unusual Q_0 vs. Eacc curve. The project accounts for a cavity performance loss from the vertical dewar test (with or without the helium vessel) to the horizontal performance in a cryomodule, such that these results leave no save margin to the cryomodule specification. Consequently, a refinement of the nitrogen-doping has been initiated to guarantee an average quench field above 20 MV/m without impeding the Q_0. This paper covers the refinement work performed for each cavity, which depends on the initial results, as well as a quench analysis carried out before and after the rework during the vertical RF tests as far as applicable.

43 PARTICLE ACCELERATORS↗

Results from the first single cell Nb 3 Sn cavity coatings at JLab

Nb 3 Sn is a promising superconducting material for SRF applications and has the potential to exceed the limitations of niobium. We have used the recently commissioned Nb 3 Sn coating system to investigate Nb 3 Sn coatings on several single cell cavities by applying the same coating procedure on several different single cells with different history and pre-coating surface preparation. We report on our findings with four 1.5 GHz CEBAF-shape single cell and one 1.3 GHz ILC-shape single cavities that were coated, inspected, and tested.

43 PARTICLE ACCELERATORS↗

Evidence of Magnetic Breakdown on the Defects With Thermally Suppressed Critical Field in High Gradient SRF Cavities

At SRF 2011 we presented the study of quenches in high gradient SRF cavities with dual mode excitation technique. The data differed from measurements done in 80's that indicated thermal breakdown nature of quenches in SRF cavities. In this contribution we present analysis of the data that indicates that our recent data for high gradient quenches is consistent with the magnetic breakdown on the defects with thermally suppressed critical field. From the parametric fits derived within the model we estimate the critical breakdown fields.

Eremeev, Grigory↗

QUENCH STUDIES AND PREHEATING ANALYSIS OF SEAMLESS

One of the alternative manufacturing technologies for SRF cavities is hydroforming from seamless tubes. Although this technology has produced cavities with gradient and Q-values comparable to standard EBW/EP cavities, a few questions remain. One of these questions is whether the quench mechanism in hydroformed cavities is the same as in standard electron beam welded cavities. Towards this effort Jefferson Lab performed quench studies on 2 9 cell seamless hydroformed cavities. These cavities include DESY's - Z163 and Z164 nine-cell cavities hydroformed at DESY. Initial Rf test results Z163 were published in SRF2011. In this report we will present post JLAB surface re-treatment quench studies for each cavity. The data will include OST and T-mapping quench localization as well as quench location preheating analysis comparing them to the observations in standard electron beam welded cavities.

Palczewski, Ari↗

NbTiN Based SIS Multilayer Structures for SRF Applications

For the past three decades, bulk niobium has been the material of choice for SRF cavities applications. RF cavity performance is now approaching the theoretical limit for bulk niobium. For further improvement of RF cavity performance for future accelerator projects, Superconductor Insulator - Superconductor (SIS) multilayer structures (as recently proposed by Alex Gurevich) present the theoretical prospect to reach RF performance beyond bulk Nb, using thinly layered higher-Tc superconductors with enhanced Hc1. Jefferson Lab (JLab) is pursuing this approach with the development of NbTiN and AlN based multilayer SIS structures. This paper presents the results on the characteristics of NbTiN films and the first RF measurements on NbTiN-based multilayer structure on thick Nb films.

Valente, Anne-marie↗

Exploration of very high gradient cavities

Several of the 9-cell ILC cavities processed at Jlab within ongoing ILC R&D program have shown interesting behavior at high fields, such as mode mixing and sudden field emission turn-on during quench. Equipped with thermometry and oscillating superleak transducer (OST) system for quench detection, we couple our RF measurements with local dissipation measurements. In this contribution we report on our findings with high gradient SRF cavities.

43 PARTICLE ACCELERATORS↗

Probing the fundamental limit of niobium in high radiofrequency fields by dual mode excitation in superconducting radiofrequency cavities

We have studied thermal breakdown in several multicell superconducting radiofrequency cavity by simultaneous excitation of two TM{sub 010} passband modes. Unlike measurements done in the past, which indicated a clear thermal nature of the breakdown, our measurements present a more complex picture with interplay of both thermal and magnetic effects. JLab LG-1 that we studied was limited at 40.5 MV/m, corresponding to B{sub peak} = 173 mT, in 8{pi}/9 mode. Dual mode measurements on this quench indicate that this quench is not purely magnetic, and so we conclude that this field is not the fundamental limit in SRF cavities.

43 PARTICLE ACCELERATORS↗

Quench studies of ILC cavities

Quench limits accelerating gradient in SRF cavities to a gradient lower than theoretically expected for superconducting niobium. Identification of the quenching site with thermometry and OST, optical inspection, and replica of the culprit is an ongoing effort at Jefferson Lab aimed at better understanding of this limiting phenomenon. In this contribution we present our finding with several SRF cavities that were limited by quench.

43 PARTICLE ACCELERATORS↗

Commissioning Cornell OSTs for SRF cavity testing at Jlab

Understanding the current quench limitations in SRF cavities is a topic essential for any SRF accelerator that requires high fields. This understanding crucially depends on correct and precise quench identification. Second sound quench detection in superfluid liquid helium with oscillating superleak transducers is a technique recently applied at Cornell University as a fast and versatile method for quench identification in SRF cavities. Having adopted Cornell design, we report in this contribution on our experience with OST for quench identification in different cavities at JLab.

43 PARTICLE ACCELERATORS↗

Studies on superconducting thin films for SRF applications

In order to overcome the fundamental limit of Nb's critical magnetic field ({approx} 200 mT) that corresponds to E{sub acc} {approx}50 MV/m, an idea of coating several thin layers of a superconductor has been proposed. MgB{sub 2}, a superconductor that has a T{sub c} of {approx}39 K, has been studied to explore the effect of coating in terms of DC and RF critical magnetic fields, and RF surface losses. MgB{sub 2} has shown an excellent behavior, although there is some discrepancy between DC and RF measurements.

36 MATERIALS SCIENCE↗