Engineering Papers⌕ Search

Engineering topics

Engels, Matthias

Publications and source records attributed to Engels, Matthias.

Electricity and Gas IDS Dataset

The following dataset was collected from a set of cybersecurity experiments conducted in an Electricity and Natural Gas environment. The architecture was instantiated within the powerNET testbed at Pacific Northwest National Laboratory, and is comprised of both simulated components and hardware-in-the-loop devices. The test environment consisted of a substation and control center network representative of electrical systems. In addition, it also contained a compressor station, and an odorizer and pressure regulation station representative of oil and natural gas systems. The various devices on the electrical and gas systems were organized into multiple networks to mimic real-world deployments. There were 14 testing scenarios overall that covered a wide variety of cybersecurity and infrastructure events.

Industrial Control↗

Electricity and Gas IDS Dataset

The following dataset was collected from a set of cybersecurity experiments conducted in an Electricity and Natural Gas environment. The architecture was instantiated within the powerNET testbed at Pacific Northwest National Laboratory, and is comprised of both simulated components and hardware-in-the-loop devices. The test environment consisted of a substation and control center network representative of electrical systems. In addition, it also contained a compressor station, and an odorizer and pressure regulation station representative of oil and natural gas systems. The various devices on the electrical and gas systems were organized into multiple networks to mimic real-world deployments. There were 14 testing scenarios overall that covered a wide variety of cybersecurity and infrastructure events.

Industrial Control↗

Energy Sector Position, Navigation, and Time Cybersecurity Profile

The Pacific Northwest National Laboratory has developed this positioning, navigation, and timing (PNT) profile for the Energy Sector at the request of the U.S. Department of Energy. The Department of Energy is the sector-specific agency for the Energy Sector and is responsible for providing guidance in the form of this PNT Profile, per Executive Order 13905, Strengthening National Resilience Through Responsible Use of Positioning, Navigation, and Timing Services (Executive Office of the President 2020) issued February 18, 2020. Executive Order 13905 directed the National Institute of Standards & Technology to develop a PNT Profile that is broadly applicable to all sectors and to serve as a foundation for sector-neutral guidance, NISTIR 8323 Foundational PNT Profile: Applying the Cybersecurity Framework for the Responsible Use of Positioning, Navigation, and Timing (PNT) Services. This document builds on NISTIR 8323 to identify and serve as the required Energy Sector specific guidance. For purposes of this PNT Profile, Energy Sector precise time is 0.5 µs (microseconds) to 1 µs accuracy. Currently, the electricity subsector has systems that use this level of precision time, but the oil and natural gas subsector currently does not. While the electricity subsector uses precision timing, it does not use positioning and/or navigation at this level of accuracy. For this reason, this PNT Profile will focus on only precise time for the electricity subsector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Automated, Disruption-Tolerant Device Authentication and Key Management Framework for Critical Systems

Key management is critical to secure operation. Distributed control systems, such as Supervisory Control and Data Acquisition (SCADA) systems, have unique operational requirements that make conventional key management solutions less effective and burdensome. In this paper a novel Kerberos based framework for automated, disruption-tolerant key management for control system environments is presented. Experimental tests and their results are presented to quantify expected performance overhead of this approach. In addition, Zeek sensor analytics are presented to monitor the health and security of the key management framework operation.

Edgar, Thomas W.↗

Safer and optimized vulnerability scanning for operational technology through integrated and automated passive monitoring and active scanning

Vulnerability scanning of embedded sensors and controllers have a history of causing disruption and malfunction within operation technology environments. Traditional information technology vulnerability scanning generally consists of blunt exercising all or a large population of test conditions to understand how equipment responds. Often the large number and varied conditions of the tests are too much for embedded systems to handle. This paper presents a methodology and framework for integrating passive monitoring and active scanning techniques to optimize the type and amount of necessary active communication tests while achieving acceptable levels of device and vulnerability discovery. Bayesian probability and networks are leveraged for inference to drive the automation of the scanning actions to achieve confidence in discovery. Through inference, selecting the optimal active scans with the least risk and highest confidence impact is possible, thereby eliminating unnecessary scans with uncertain effects. Results of experimenting with real power systems and the following probabilities are provided.

Key Management, ICS, SCADA, Authentication↗

MS-SPEAK: Final Report and Implementation Roadmap

This report describes the scope and results of a project undertaken to help consumer-owned electric utilities improve the cybersecurity of their system interfaces. The team developed a cybersecurity reference architecture for the MultiSpeak interoperability standard, which is used by many of these consumer-owned utilities and their supporting vendors. The analysis and use cases focused on the Remote Connect/Disconnect (RCD) interface, and its vulnerabilities. An open-source toolkit has also been developed to facilitate customized intrusion detection systems (IDS) for MultiSpeak applications. This report includes a roadmap for others to use and customize this IDS toolkit for additional MultiSpeak versions and interfaces.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Multi-level Fidelity Microgrid Testbed Model for Cybersecurity Experimentation

When experimenting with cybersecurity technologies for industrial control systems, it is often difficult to develop a realistic, self-contained model that provides an ability to easily measure the effects of cyber behavior on the associated physical system. To address this challenge, we have created and instantiated a microgrid cyber-physical model, where both the power distribution and the individual loads are under the control and authority of one entity. This enables cybersecurity experimentation where attacks against the physical system (grid and buildings) can be measured and defended from a single entities infrastructure. To achieve the appropriate levels of fidelity for cybersecurity effects, our microgrid model integrates multiple levels of simulation, hardware-in-the-loop, and virtualization. In this paper, we present how we designed and instantiated this test case model in a testbed infrastructure, our efforts to validate its operation, and an exemplary multistage attack scenario to showcase the model's utility.

Ashok, Aditya↗

Smart and Green Energy (SAGE) for Base Camps Final Report

The U.S. Army Logistics Innovation Agency’s (LIA’s) Smart and Green Energy (SAGE) for Base Camps project was to investigate how base camps’ fuel consumption can be reduced by 30% to 60% using commercial off-the-shelf (COTS) technologies for power generation, renewables, and energy efficient building systems. Field tests and calibrated energy models successfully demonstrated that the fuel reductions are achievable.

energy↗