Engineering Papers⌕ Search

Engineering topics

Elliott, Steven Ray

Publications and source records attributed to Elliott, Steven Ray.

At least 19 records

The Gallium Anomaly and the BEST Experiment [Slides]

The measurements of the charged-current capture rate of neutrinos on 71 Ga from strong radioactive sources have yielded results below those expected, based on the known strength of the principal transition supplemented by theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Isomers and Dark Matter: 180m Ta and 178m Hf [Slides]

Dark matter has attractive gravitational interactions. It does not interact with light, or has very small electromagnetic coupling. It is stable, or has a lifetime much longer than the age of the Universe. No departure model from the law of gravity explains all data, whereas particle dark matter can.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark Matter Constraints from Isomeric 178⁢m Hf

In this article, we describe a first measurement of the radiation from a 178⁢m Hf sample to search for dark matter. The $\gamma$ flux from this sample, possessed by Los Alamos National Laboratory nuclear chemistry, was measured with a Ge detector at a distance of 1.2 m due to its high activity. We search for $\gamma$’s that cannot arise from the radioactive decay of 178⁢m Hf but might arise from the production of a nuclear state due to the inelastic scattering with dark matter. The limits obtained on this $\gamma$ flux are then translated into constraints on the parameter space of inelastic dark matter. Finally, we describe the potential reach of future studies with 178⁢m Hf.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.

47 OTHER INSTRUMENTATION↗

Variable energy X-ray fluorescence source

Here we detail the design of a variable energy, x-ray fluorescence source using a low activity (1.8×10 6 dpm) 99 Tc β source that irradiates thin foils. By rotating the source among foils of Ti, Zn, Nb, Ag, and Au, the device produces x rays between 4 and 70 keV at a rate near 1 Hz. When the source is placed in a storage position, the external radiation is non-detectable. The design of the shielding and rotation mechanism permits use in vacuum and at liquid nitrogen temperature. The design is intended for the study of the low energy response to radiation impinging upon Ge detector surfaces. The source will be useful for understanding the detector response in large-scale Ge arrays such as MAJORANA and LEGEND.

47 OTHER INSTRUMENTATION↗

Understanding the enhancement of scintillation light in xenon-doped liquid argon

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based detectors. In liquid argon, the light yield can be enhanced by the addition of a small quantity of xenon, where ~10–1000 ppm are added. The general enhancement mechanism and its pathway via an energy transfer between argon and xenon excimers is well known, however the importance of absorption of argon excimer emission by atomic xenon has not been fully appreciated. This absorption significantly reduces the light yield in commercially available argon (extracted from air) which contains trace amounts (~0.1 ppm) of xenon. The addition of a small xenon dopant of ~10 ppm recovers this lost light resulting in an increased light yield over un-doped argon of about a factor of two. Here, in this paper, we introduce a model for the light production in xenon doped argon, including absorption and re-emission, and compare it to the measured time dependence of light emission in xenon-doped argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Large Enriched Germanium Experiment for Neutrinoless ββ Decay (LEGEND-1000 Preconceptual Design Report)

We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless ββ Decay. This experiment is an international project designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the 76 Ge isotope of interest operated in a liquid argon active shield at a deep underground lab. The experiment is designed to achieve a discovery potential that covers the inverted-ordering neutrino mass scale region. The baseline design assumes installation in the SNOLAB cryopit. A similar experimental setup could also be realized at the LNGS alternative site.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large-scale, precision xenon doping of liquid argon

The detection of scintillation light from liquid argon is an experimental technique key to a number of current and future nuclear/particle physics experiments, such as neutrino physics, neutrinoless double beta decay and dark matter searches. Additionally, although the idea of adding small quantities of xenon (doping) to enhance the light yield has attracted considerable interest, this technique has never been demonstrated at the necessary scale or precision. Here we report on xenon doping in a 100 l cryogenic vessel. Xenon doping was performed in four concentrations of 1.00 ± 0.06 ppm, 2.0 ± 0.1 ppm, 5.0 ± 0.3 ppm, and 10.0 ± 0.5 ppm. These measurements represent the most precise xenon doping measurements as of publishing. We observed an increase in average light yield by a factor of 1.92 ± 0.12(syst) ± 0.02(stat) at a dopant concentration of 10 ppm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of the MAJORANA DEMONSTRATOR’s Search for Double-Beta Decay of 76 Ge to Excited States of 76 Se

The MAJORANA DEMONSTRATOR is searching for double-beta decay of 76 Ge to excited states (E.S.) in 76Se using a modular array of high purity Germanium detectors. 76 Ge can decay into three E.S.s of 76 Se. The E.S. decays have a clear event signature consisting of a ββ-decay with the prompt emission of one or two γ-rays, resulting in with high probability in a multi-site event. The granularity of the DEMONSTRATOR detector array enables powerful discrimination of this event signature from backgrounds. Using 21.3 kg-y of isotopic exposure, the DEMONSTRATOR has set world leading limits for each E.S. decay, with 90% CL lower half-life limits in the range of (0.56 – 2.1) • 10 24 y. In particular, for the 2v transition to the first 0 + E.S. of 76 Se, a lower half-life limit of 0.68 • 10 24 at 90% CL was achieved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LEGEND

Explore the source record for details and available documents.

Atomic, Nuclear and Particle Physics↗