Engineering Papers⌕ Search

Engineering topics

Elliott, James R.

Publications and source records attributed to Elliott, James R..

22 records · Page 2

Ferritin-Templated Quantum-Dots for Quantum Logic Gates

Quantum logic gates (QLGs) or other logic systems are based on quantum-dots (QD) with a stringent requirement of size uniformity. The QD are widely known building units for QLGs. The size control of QD is a critical issue in quantum-dot fabrication. The work presented here offers a new method to develop quantum-dots using a bio-template, called ferritin, that ensures QD production in uniform size of nano-scale proportion. The bio-template for uniform yield of QD is based on a ferritin protein that allows reconstitution of core material through the reduction and chelation processes. One of the biggest challenges for developing QLG is the requirement of ordered and uniform size of QD for arrays on a substrate with nanometer precision. The QD development by bio-template includes the electrochemical/chemical reconsitution of ferritins with different core materials, such as iron, cobalt, manganese, platinum, and nickel. The other bio-template method used in our laboratory is dendrimers, precisely defined chemical structures. With ferritin-templated QD, we fabricated the heptagonshaped patterned array via direct nano manipulation of the ferritin molecules with a tip of atomic force microscope (AFM). We also designed various nanofabrication methods of QD arrays using a wide range manipulation techniques. The precise control of the ferritin-templated QD for a patterned arrangement are offered by various methods, such as a site-specific immobilization of thiolated ferritins through local oxidation using the AFM tip, ferritin arrays induced by gold nanoparticle manipulation, thiolated ferritin positioning by shaving method, etc. In the signal measurements, the current-voltage curve is obtained by measuring the current through the ferritin, between the tip and the substrate for potential sweeping or at constant potential. The measured resistance near zero bias was 1.8 teraohm for single holoferritin and 5.7 teraohm for single apoferritin, respectively.

Choi, Sang H.↗

Biologically Derived Nanoparticle Arrays via a Site-Specific Reconstitution of Ferritin and their Electrochemistry

Nanoparticle arrays biologically derived from an electrochemically-controlled site-specific biomineralization were fabricated on a gold substrate through the immobilization process of biomolecules. The work reported herein includes the immobilization of ferritin with various surface modifications, the electrochemical biomineralization of ferritins with different inorganic cores, the fabrication of self-assembled arrays with the immobilized ferritin, and the electrochemical characterization of various core materials. Protein immobilization on the substrate is achieved by anchoring ferritins with dithiobis-N-succinimidyl propionate (DTSP). A reconstitution process of electrochemical site-specific biomineralization with a protein cage loads ferritins with different core materials such as Pt, Co, Mn, and Ni. The ferritin acts as a nano-scale template, a biocompatible cage, and a separator between the nanoparticles. The nano-sized metalcored ferritins on a gold substrate displayed a good electrochemical activity for the electron transport and storage, which is suitable for bioelectronics applications such as biofuel cell, bionanobattery, biosensors, etc. Keywords: Ferritin, immobilization, site-specific reconstitution, biomineralization, and bioelectronics

Kim, Jae-Woo↗

Vortex flap flight test operations, a safe approach

A flight test experiment was conducted at the Langley Research Center to evaluate a wing leading-edge vortex flap concept designed for use on an aircraft with highly swept wings. The flap concept was designed as a modification to the wing leading edge of an F-106B airplane. The flight testing required operations at conditions that would exceed the structural load envelope of the basic airplane in order to acquire desired research data for the modified configuration. Accordingly, the operational envelope of the modified aircraft was incrementally expanded and real-time monitoring of airframe strains at critical wing locations was mandated to insure safety of flight. The flight tests were conducted in two phases: Phase I to establish baseline data with the unmodified wing, and Phase II to determine the effects of the vortex flap on performance, handling qualities, and flow field characteristics. This paper focuses on a description of the approach and procedures used to provide the strain-gage monitoring to insure structural integrity. Highlights of the wing modification and the overall operation are also included. Within a -year period, 110 research flights were successfully completed, providing researchers with sufficient data to assess the potential benefits ascribed to the vortex flap concept without encountering severe structural problems or mishaps.

Dicarlo, Daniel J.↗

Shaft Adapter For Data Coupler

Shaft adapter developed to provide means for securing Acurex 1200B universal data coupler to rotating instrumented shaft. Consists of two major parts: shaft sleeve and shaft clamp. Provides for accurate measurements of stresses and strains in shaft.

Elliott, James R.↗