Engineering Papers⌕ Search

Engineering topics

Ejiri, H.

Publications and source records attributed to Ejiri, H..

At least 55 records · Page 3

Status of the MAJORANA DEMONSTRATOR

The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultralow background, 40-kg modular high purity Ge (HPGe) detector array to search for neutrinoless double-beta decay (0νββ-decay) in 76 Ge. The goal of the experiment is to demonstrate a background rate at or below 3 counts/(t-y) in the 4 keV region of interest (ROI) around the 2039 keV Q-value for 76 Ge 0νββ-decay. In this study, the status of the MAJORANA DEMONSTRATOR, including its design and measurements of properties of the HPGe crystals is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Majorana Demonstrator search for neutrinoless double beta decay

The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7 kg enriched 88% in 76Ge) to search for neutrinoless double beta decay in 76Ge. The next generation of tonnescale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalable to the next generation experiment. First data taken with the DEMONSTRATOR are introduced here.

Cuesta, C.↗

Search for Pauli exclusion principle violating atomic transitions and electron decay with a p-type point contact germanium detector

Here, a search for Pauli-exclusion-principle-violating K α electron transitions was performed using 89.5 kg-d of data collected with a p-type point contact high-purity germanium detector operated at the Kimballton Underground Research Facility. A lower limit on the transition lifetime of 5.8 × 10 30 s at 90% C.L. was set by looking for a peak at 10.6 keV resulting from the X-ray and Auger electrons present following the transition. A similar analysis was done to look for the decay of atomic K-shell electrons into neutrinos, resulting in a lower limit of 6.8 × 10 30 s at 90% C.L. It is estimated that the Majorana Demonstrator, a 44 kg array of p-type point contact detectors that will search for the neutrinoless double-beta decay of 76 Ge, could improve upon these exclusion limits by an order of magnitude after three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy-resolution measurement of the Se 82 ( He 3 , t ) Br 82 reaction for double- β decay and for solar neutrinos

For this study, a high-resolution ( 3 He,t) charge-exchange experiment at an incident energy of 420 MeV has been performed on the double beta (ββ) decay nucleus 82 Se. A detailed Gamow-Teller (GT - ) strength distribution in 82 Br has been extracted, which provides information to the ββ-decay nuclear matrix elements. Three strong and isolated transitions, which are to the 75, 1484 and the 2087 keV states in 82 Br, are found to dominate the low-excitation region below ≈ 2.1 MeV. Above 2.1 MeV a sudden onset of a strong GT fragmentation is observed. The degree of fragmentation resembles a situation found in the neighboring A = 76 system 76 Ge, whereas the observed concentration of strength in the three low-lying states is reminiscent of the heavier neighbors 96 Zr and 100 Mo. The strong GT transition to the 75 keV (1 + ) state makes 82 Se interesting for solar neutrino detection. The 82 Se(ν e ,e - ) 82 Br solar neutrino capture rate in a nonoscillation scenario is therefore evaluated to 668 ± 12(stat) ± 60(sys) SNU, and some of the advantages of using selenium for solar neutrino studies are discussed.

59 ≤ A ≤ 89↗

High voltage testing for the Majorana Demonstrator

The Majorana Collaboration is constructing theMajorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of theMajorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during theMajorana Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

high-voltage↗

The Majorana Demonstrator radioassay program

The Majorana collaboration is constructing the Majorana Demonstrator at the Sanford Underground Research Facility at the Homestake gold mine, in Lead, SD. The apparatus will use Ge detectors, enriched in isotope 76 Ge, to demonstrate the feasibility of a large-scale Ge detector experiment to search for neutrinoless double beta decay. The long half-life of this postulated process requires that the apparatus be extremely low in radioactive isotopes whose decays may produce backgrounds to the search. The radioassay program conducted by the collaboration to ensure that the materials comprising the apparatus are sufficiently pure is described. The resulting measurements from gamma-ray counting, neutron activation and mass spectroscopy of the radioactive-isotope contamination for the materials studied for use in the detector are reported. In conclusion, we interpret these numbers in the context of the expected background for the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the Majorana Demonstrator

The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44-kg (29 kg {sup 76}Ge and 15 kg {sup nat}Ge) to search for neutrinoless double beta decay in {sup 76}Ge. The next generation of tonne-scale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalable to the next generation experiment. First, the prototype module was assembled; it has been continuously taking data from July 2014 to June 2015. Second, Module 1 with more than half of the total enriched detectors and some natural detectors has been assembled and it is being commissioned. Finally, the assembly of Module 2, which will complete MAJORANA DEMONSTRATOR, is already in progress.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low background signal readout electronics for the MAJORANA DEMONSTRATOR

The MAJORANA Collaboration will seek neutrinoless double beta decay (0νββ) in {sup 76}Ge using isotopically enriched p-type point contact (PPC) high purity Germanium (HPGe) detectors. A tonne-scale array of HPGe detectors would require background levels below 1 count/ROI-tonne-year in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the decay. In order to demonstrate the feasibility of such an experiment, the MAJORANA DEMONSTRATOR, a 40 kg HPGe detector array, is being constructed with a background goal of < 3 count/ROI-tonne-year, which is expected to scale down to < 1 count/ROI-tonne-year for a tonne-scale experiment. The signal readout electronics, which must be placed in close proximity to the detectors, present a challenge toward reaching this background goal. This talk will discuss the materials and design used to construct signal readout electronics with low enough backgrounds for the MAJORANA DEMONSTRATOR.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis techniques for background rejection at the MAJORANA DEMONSTRATOR

The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 40- kg modular HPGe detector array to search for neutrinoless double beta decay in {sup 76}Ge. In view of the next generation of tonne-scale Ge-based 0νβ β-decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value at 2039 keV. The background rejection techniques to be applied to the data include cuts based on data reduction, pulse shape analysis, event coincidences, and time correlations. The Point Contact design of the DEMONSTRATOR’s germanium detectors allows for significant reduction of gamma background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status Update of the Majorana Demonstrator Neutrinoless Double Beta Decay Experiment

Neutrinoless double beta decay searches play a major role in determining neutrino properties, in particular the Majorana or Dirac nature of the neutrino and the absolute scale of the neutrino mass. The consequences of these searches go beyond neutrino physics, with implications for Grand Unification and leptogenesis. The Majorana Collaboration is assembling a low-background array of high purity Germanium (HPGe) detectors to search for neutrinoless double-beta decay in 76Ge. The Majorana Demonstrator, which is currently being constructed and commissioned at the Sanford Underground Research Facility in Lead, South Dakota, will contain 44 kg (30 kg enriched in 76Ge) of HPGe detectors. Its primary goal is to demonstrate the scalability and background required for a tonne-scale Ge experiment. This is accomplished via a modular design and projected background of less than 3 cnts/tonne-yr in the region of interest. The experiment is currently taking data with the first of its enriched detectors.

Majorana Demonstrator↗

Status of the Majorana Demonstrator

The Majorana Collaboration is constructing the Majorana Demonstrator, an ultra-low background, 40-kg modular high purity Ge detector array to search for neutrinoless double-beta decay in 76 Ge. In view of the next generation of tonne-scale Ge-based neutrinoless double-beta decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value at 2039 keV. Lastly, the current status of the Demonstrator is discussed, as are plans for its completion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Dark Matter Search with MALBEK

The Majorana Demonstrator is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of 76Ge and perform a search for weakly interacting massive particles (WIMPs) with masses below 10 GeV. As part of the Majorana research and development efforts, we have deployed a modified, low-background broad energy germanium detector at the Kimballton Underground Research Facility. With its sub-keV energy threshold, this detector is potentially sensitive to non-Standard Model physics, including interactions with WIMPs. We discuss the backgrounds present in the WIMP region of interest and present results from a WIMP search with 221.49 live days of data from this detector.

Giovanetti, G. K.↗

Background Model for the Majorana Demonstrator

The Majorana Collaboration is constructing a prototype system containing 40 kg of HPGe detectors to demonstrate the feasibility and potential of a future tonne-scale experiment to search for neutrinoless double-beta (0v BB) decay in 76Ge. In view of the requirement that the next generation of tonne-scale Ge-based 0vBB-decay experiment be capable of probing the neutrino mass scale in the inverted-hierarchy region, a major goal of theMajorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in the 4 keV region of interest around the Q-value at 2039 keV. This goal is pursued through a combination of a significant reduction of radioactive impurities in construction materials with analytical methods for background rejection, for example using powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using Geant4 simulations of the different background components whose purity levels are constrained from radioassay measurements.

Cuesta, C.↗

The Majorana Demonstrator: A Search for Neutrinoless Double-beta Decay of 76 Ge

Neutrinoless double-beta (0νββ) decay is a hypothesized process where in some even-even nuclei it might be possible for two neutrons to simultaneously decay into two protons and two electrons without emitting neutrinos. This is possible only if neutrinos are Majorana particles, i.e. fermions that are their own antiparticles. Neutrinos being Majorana particles would explicitly violate lepton number conservation, and might play a role in the matter-antimatter asymmetry in the universe. The observation of neutrinoless double-beta decay would also provide complementary information related to neutrino masses. The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, a 40-kg modular germanium detector array, to search for the 0νββ decay of 76Ge and to demonstrate a background rate at or below 3 counts/(ROI-t-y) in the 4 keV region of interest (ROI) around the 2039 keV Q-value for 76Ge 0νββ decay. In this paper, we discuss the physics of neutrinoless double beta decay and then focus on the MAJORANA DEMONSTRATOR, including its design and approach to achieve ultra-low backgrounds and the status of the experiment.

Xu, W.↗

MAJORANA Collaboration's Experience with Germanium Detectors

A unique way to explore the nature of the neutrino is the search for neutrinoless double beta decay (0νββ). Observation of 0νββ-decay would decisively prove that neutrinos are Majorana particles and that lepton number is violated. The Majorana Demonstrator will perform a search for 0νββ-decay in 76Ge. The experiment is currently under construction at the Sanford Underground Facility (SURF) in South Dakota, USA. The Majorana Demonstrator will use an array of 40 kg of high purity germanium detectors, up to 30 kg of which will be enriched to 86% in 76Ge, surrounded by passive and active shielding. The major goal is to demonstrate a path forward to achieving a background rate at or below 3 counts/(ROI-t-y) in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the 76Ge 0νββ decay. This is required for the next generation of tonne-scale germanium-based 0νββ-decay searches that are designed to probe the neutrino mass scale in the inverted-hierarchy region. Beyond the usage of ultra-clean material and extensive shielding, a key feature to achieve a low background level is a high energy resolution to minimize the ROI and pulse-shape discrimination capability to distinguish signal from background events. These properties are provided by High Purity (HP) P-type Point Contact (PPC) germanium (Ge) detectors. By enriching the natural germanium to 87% in 76Ge the detectors can be used as source and detector simultaneously. At the time of this presentation, 30 enriched detectors with average mass of 840 g have been delivered and successfully tested at SURF. All detectors met the requirements during characterization in vendor cryostat and are now being assembled in the final Majorana Demonstrator experiment.

Mertens, S.↗

Low background signal readout electronics for the Majorana Demonstrator

The Majorana Demonstrator is a planned 40 kg array of Germanium detectors intended to demonstrate the feasibility of constructing a tonne-scale experiment that will seek neutrinoless double beta decay (0νββ) in 76 Ge. In such an experiment we require backgrounds of less than 1 count/tonne-year in the 4 keV region of interest around the 2039 keV Q-value of the ββ decay. Moreover, designing low-noise electronics, which must be placed in close proximity to the detectors, presents a challenge to reaching this background target. Finally, this paper will discuss the Majorana collaboration's solutions to some of these challenges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the MAJORANA DEMONSTRATOR: A search for neutrinoless double-beta decay

If neutrinos are Majorana particles, i.e. fermions that are their own antiparticles, then neutrinoless double-beta (0νββ) decay is possible. In such a process, two neutrons can simultaneously decay into two protons and two electrons without emitting neutrinos. Neutrinos being Majorana particles would explicitly violate lepton number conservation, and might play a role in the matter–antimatter asymmetry in the universe. The MAJORANA DEMONSTRATOR experiment is under construction at the Sanford Underground Research Facility in Lead, SD and will search for the neutrinoless double-beta (0νββ) decay of the 76 Ge isotope. The goal of the experiment is to demonstrate that it is possible to achieve a sufficiently low background rate in the 4 keV region of interest (ROI) around the 2039 keV Q-value to justify building a tonne-scale experiment. In this study, we discuss the physics and design of the MAJORANA DEMONSTRATOR, its approach to achieving ultra-low background and the status of the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Majorana Parts Tracking Database

The MAJORANA DEMONSTRATOR is an ultra-low background physics experiment searching for the neutrinoless double beta decay of 76Ge. The MAJORANA Parts Tracking Database is used to record the history of components used in the construction of the DEMONSTRATOR. Transportation, storage, and processes undergone by parts such as machining or cleaning are linked to part records. Tracking parts provides a great logistics benefit and an important quality assurance reference during construction. In addition, the location history of parts provides an estimate of their exposure to cosmic radiation. A web application for data entry and a radiation exposure calculator have been developed as tools for achieving the extreme radiopurity required for this rare decay search.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗