Engineering PapersSearch

Engineering topics

Eberhardt, R. N.

Publications and source records attributed to Eberhardt, R. N..

At least 19 records

Development of the Cassini Spacecraft Propulsion Subsystem

The Cassini Spacecraft will be launched on an expedition to Saturn in October 1997. The mission is an eleven year operation, the first seven years traveling to Saturn via a combination of propulsion burns and Venus-Venus-Earth-Jupiter gravity-assist, and the remaining four years orbiting Saturn while exploring the planet, it's moons, rings, and nearby icy satellites.

Cassini

Orbital fluid servicing and resupply operations

The capability to reservice spacecraft and satellites with expendable fluids will provide significant increases in the usability, operational efficiency and cost effectiveness of in-space systems. Initial resupply will be accomplished from the Orbiter cargo bay starting with monopropellant servicing which will eventually be extended to servicing of bipropellants and pressurants. Other fluids, such as freon, ammonia, methanol, superfluid helium, and liquid/gaseous nitrogen may also need to be resupplied once a space station becomes a reality. These fluids/gases are required for subsystem working fluid replacement and payload/experiment fluid replenishment. A logistics module operating on a 90 day schedule is planned for space station servicing. Resupplying hundreds of thousands of pounds of cryogenic propellants and reactants for users such as the Orbital Transfer Vehicle (OTV) also represents future logistics challenges. Implementation of on-orbit fluid transfer requires solving many problems including fluid management in the low-g environment, system docking and interface mating, configuration of user friendly avionics to monitor and control the entire servicing operation, and minimized maintenance and enhanced reliability. Candidate fluid transfer methods and possible gas transfer methods are discussed, and preliminary storable monopropellant and bipropellant tanker designs are summarized.

Eberhardt, R. N.

Orbital spacecraft resupply technology

The resupplying of orbital spacecraft using the Space Shuttle, Orbital Maneuvering Vehicle, Orbital Transfer Vehicle or a depot supply at a Space Station is studied. The governing factor in fluid resupply designs is the system size with respect to fluid resupply quantities. Spacecraft propellant management for tankage via diaphragm or surface tension configurations is examined. The capabilities, operation, and application of adiabatic ullage compression, ullage exchange, vent/fill/repressurize, and drain/vent/no-vent fill/repressurize, which are proposed transfer methods for spacecraft utilizing tankage configurations, are described. Selection of the appropriate resupply method is dependent on the spacecraft design features. Hydrazine adiabatic compression/detonation, liquid-free vapor venting to prevent freezing, and a method for no-vent liquid filling are analyzed. Various procedures for accurate measurements of propellant mass in low gravity are evaluated; a system of flowmeters with a PVT system was selected as the pressurant solubility and quantity gaging technique. Monopropellant and bipropellant orbital spacecraft consumable resupply system tanks which resupply 3000 lb of hydrazine and 7000 lb of MMH/NTO to spacecraft on orbit are presented.

Eberhardt, R. N.

Cryogenic Fluid Management Facility

The Cryogenic Fluid Management Facility is a reusable test bed which is designed to be carried within the Shuttle cargo bay to investigate the systems and technologies associated with the efficient management of cryogens in space. Cryogenic fluid management consists of the systems and technologies for: (1) liquid storage and supply, including capillary acquisition/expulsion systems which provide single-phase liquid to the user system, (2) both passive and active thermal control systems, and (3) fluid transfer/resupply systems, including transfer lines and receiver tanks. The facility contains a storage and supply tank, a transfer line and a receiver tank, configured to provide low-g verification of fluid and thermal models of cryogenic storage and transfer processes. The facility will provide design data and criteria for future subcritical cryogenic storage and transfer system applications, such as Space Station life support, attitude control, power and fuel depot supply, resupply tankers, external tank (ET) propellant scavenging, and ground-based and space-based orbit transfer vehicles (OTV).

Eberhardt, R. N.

On-orbit cryogenic fluid transfer

A number of future NASA and DOD missions have been identified that will require, or could benefit from resupply of cryogenic liquids in orbit. The most promising approach for accomplishing cryogenic fluid transfer in the weightlessness environment of space is to use the thermodynamic filling technique. This approach involves initially reducing the receiver tank temperature by using several charge hold vent cycles followed by filling the tank without venting. Martin Marietta Denver Aerospace, under contract to the NASA Lewis Research Center, is currently developing analytical models to describe the on orbit cryogenic fluid transfer process. A detailed design of a Shuttle attached experimental facility, which will provide the data necessary to verify the analytical models, is also being performed.

Aydelott, J. C.

Cryogenic Fluid Management Facility

The Cryogenic Fluid Management Facility (CFMF) is a reusable test bed which is designed to be carried into space in the Shuttle cargo bay to investigate systems and technologies required to efficiently and effectively manage cryogens in space. The facility hardware is configured to provide low-g verification of fluid and thermal models of cryogenic storage, transfer concepts and processes. Significant design data and criteria for future subcritical cryogenic storage and transfer systems will be obtained. Future applications include space-based and ground-based orbit transfer vehicles (OTV), space station life support, attitude control, power and fuel depot supply, resupply tankers, external tank (ET) propellant scavenging, space-based weapon systems and space-based orbit maneuvering vehicles (OMV). This paper describes the facility and discusses the cryogenic fluid management technology to be investigated. A brief discussion of the integration issues involved in loading and transporting liquid hydrogen within the Shuttle cargo bay is also included.

Eberhardt, R. N.

Propellant transfer: Attached depot

Propellant transfer at an attached depot involves: (1) resupply tankers (dedicated launch from the ground or scavenging from the external tank) to resupply the depot; (2) depot storage and supply tanks (attached, free-flyer, or tethered) from which liquid hydrogen and liquid oxygen are transferred to fill the space-based OTV; and (3) the space-based OTV which is resupplied with cryogens from the depot. Liquid storage and supply, thermal control, and transfer/resupply requirements for an attached depot are listed, and technologies defined. The specific fluid management elements and approaches for an attached depot are enumerated. The cryogenic fluid management facility (CFMF) shuttle attached-payload test bed, scheduled for a mid-1988 first launch, is expected to provide much of the needed technology.

Eberhardt, R. N.

On-orbit cryogenic fluid transfer

A number of future NASA and DOD missions have been identified that will require, or could benefit from resupply of cryogenic liquids in orbit. The most promising approach for accomplishing cryogenic fluid transfer in the weightlessness environment of space is to use the thermodynamic filling technique. This approach involves initially reducing the receiver tank temperature by using several charge hold vent cycles followed by filling the tank without venting. Martin Marietta Denver Aerospace, under contract to the NASA Lewis Research Center, is currently developing analytical models to describe the on orbit cryogenic fluid transfer process. A detailed design of a shuttle attached experimental facility, which will provide the data necessary to verify the analytical models, is also being performed.

Aydelott, J. C.

On-orbit cryogenic storage and resupply

Methods of integrating pressure control, liquid acquisition, and liquid transfer concepts for the Cryogenic Fluid Management Facility, a reusable test bed in the Shuttle cargo bay studying the efficient management of cryogens in space, are investigated. Significant design data and criteria for future subcritical cryogenic storage and transfer systems are presented. Technology requirements for liquid storage/supply systems, thermal control systems, and fluid transfer/resupply are addressed, and fluid and thermal analysis pertaining to receiver tank chilldown and no-vent fill of the receiver tank are discussed.

Eberhardt, R. N.

Long term storage of cryogens in space

Experimental design procedures leading to the configuration of a space-based cryogenic fluids test system are reported. Large quantities of cryogenic fluids are expected to be required in space for cooling systems, chemical and electrical OTVs, and resupply tankers. The design was guided by the necessity for representative storage and supply systems to be compatible with the Shuttle. Consideration was given to liquid hydrogen, oxygen, methane, and argon containers and concommitant fluid dynamics, thermal, and structural analyses. A 5% initial ullage was included for the liquids, except for methane, which was calculated at 8.9%. The Ar, CH4, and O2 tanks were set at 12.5 cu m, while the H2 tank was 37.4 cu m. The orbital experiment is required to provide actual thermal stabilization lags in a zero-g environment. Details of the Cryogenic Fluid Management Facility test module for flight on board the Shuttle are presented.

Fester, D. A.

Cryogenic fluid management experiment

The cryogenic fluid management experiment (CFME), designed to characterize subcritical liquid hydrogen storage and expulsion in the low-q space environment, is discussed. The experiment utilizes a fine mesh screen fluid management device to accomplish gas-free liquid expulsion and a thermodynamic vent system to intercept heat leak and control tank pressure. The experiment design evolved from a single flight prototype to provision for a multimission (up to 7) capability. A detailed design of the CFME, a dynamic test article, and dedicated ground support equipment were generated. All materials and parts were identified, and components were selected and specifications prepared. Long lead titanium pressurant spheres and the flight tape recorder and ground reproduce unit were procured. Experiment integration with the shuttle orbiter, Spacelab, and KSC ground operations was coordinated with the appropriate NASA centers, and experiment interfaces were defined. Phase 1 ground and flight safety reviews were conducted. Costs were estimated for fabrication and assembly of the CFME, which will become the storage and supply tank for a cryogenic fluid management facility to investigate fluid management in space.

Eberhardt, R. N.

An experiment to evaluate liquid hydrogen storage in space

The design and verification of a Cryogenic Fluid Management Experiment for orbital operation on the Shuttle is described. The experiment will furnish engineering data to establish design criteria for storage and supply of cryogenic fluids, mainly hydrogen, for use in low gravity environments. The apparatus comprises an LAD (liquid acquisition device) and a TVS (thermodynamic vent system). The hydrogen will be either vented or forced out by injected helium and the flow rates will be monitored. The data will be compared with ground-based simulations to determine optimal flow rates for the pressurizing gas and the release of the cryogenic fluid. It is noted that tests on a one-g, one-third size LAD system are under way.

Eberhardt, R. N.

Shuttle compatible cryogenic liquid storage and supply systems

A detailed introduction is given to a wide variety of orbital cryogenic liquid storage and supply systems required for future vehicles by NASA and DOD. The systems include small cooling applications, large chemical and electrical orbit transfer vehicles and resupply tankers, and all have the common requirements of low-g fluid management for the accomplishment of gas-free liquid expulsion, and efficient thermal control in order to manage heat leak and tank pressure. The present study considers hydrogen, oxygen, methane, argon and helium tanks ranging from 0.6 to 37.4 cu m. Conceptual designs were generated for each tank system, and fluid dynamic, structural and thermal analyses were performed in view of Shuttle requirements.

Eberhardt, R. N.

Conceptual design and analysis of orbital cryogenic liquid storage and supply systems

A wide variety of orbital cryogenic liquid storage and supply systems are defined in NASA and DOD long-range plans. These systems include small cooling applications, large chemical and electrical orbit transfer vehicles and supply tankers. All have the common requirements of low-g fluid management to accomplish gas-free liquid expulsion and efficient thermal control to manage heat leak and tank pressure. A preliminary design study was performed to evaluate tanks ranging from 0.6 to 37.4 cu m (22 to 1320 cu ft). Liquids of interest were hydrogen, oxygen, methane, argon and helium. Conceptual designs were generated for each tank system and fluid dynamic, thermal and structural analyses were performed for Shuttle compatible operations. Design trades considered the paradox of conservative support structure and minimum thermal input. Orbital performance and weight data were developed, and a technology evaluation was completed.

Eberhardt, R. N.

A liquid hydrogen experiment as a Shuttle payload

The paper describes the cryogenic fluid management experiment (CFME) as a Shuttle payload. The experiment includes a liquid hydrogen tank containing a fine-mesh screen acquisition device, and a thermal control system consisting of a thermodynamic vent system to intercept heat leak to the hydrogen tank and control tank pressure. Engineering data obtained will be used to establish design criteria for subcritical cryogenic storage and supply tankage.

Eberhardt, R. N.

Single-Donor Leukophoretic Technique

Leukocyte separation-and-retrieval device utilizes granulocyte and monocyte property of leukoadhesion to glass surfaces as basis of their separation from whole blood. Device is used with single donor technique and has application in biological and chemical processing, veterinary research and clinical care.

Eberhardt, R. N.

Behavior of fluids in a weightless environment

Fluid behavior in a low-g environment is controlled primarily by surface tension forces. Certain fluid and system characteristics determine the magnitude of these forces for both a free liquid surface and liquid in contact with a solid. These characteristics, including surface tension, wettability or contact angle, system geometry, and the relationships governing their interaction, are discussed. Various aspects of fluid behavior in a low-g environment are then presented. This includes the formation of static interface shapes, oscillation and rotation of drops, coalescence, the formation of foams, tendency for cavitation, and diffusion in liquids which were observed during the Skylab fluid mechanics science demonstrations. Liquid reorientation and capillary pumping to establish equilibrium configurations for various system geometries, observed during various free-fall (drop-tower) low-g tests, are also presented. Several passive low-g fluid storage and transfer systems are discussed. These systems use surface tension forces to control the liquid/vapor interface and provide gas-free liquid transfer and liquid-free vapor venting.

Fester, D. A.

Space Shuttle Reaction Control Subsystem propellant acquisition

A surface tension propellant acquisition/expulsion configuration was selected for the Space Shuttle Reaction Control Subsystem tankage to supply gas-free propellant during the low- and high-g operational environment (.00001 to 3.0 g) plus the numerous omnidirectional intermittent (pulse) demands of each mission. Candidate concepts to meet these stringent requirements were identified; this was followed by analysis and design sensitivity evaluations. A trade study resulted in the selection of a compartmented tank with individual flow channels as the preferred concept. Details of the analysis and design are presented.

Fester, D. A.