Engineering Papers⌕ Search

Engineering topics

Dunn, Michael E

Publications and source records attributed to Dunn, Michael E.

At least 19 records

A Case Study in the Application of TSUNAMI-3D Part 1, Multigroup

The use of the sensitivity and uncertainty tool suite within SCALE, known as the TSUNAMI suite, has grown following its initial introduction more than a decade ago. Proper use of these tools provides a more complete understanding of system responses to perturbations, especially in the area of nuclear cross section uncertainties. Recent advances within TSUNAMI have added generalized perturbation theory to the keff sensitivity capability that was included in TSUNAMI originally. The generation of sensitivity data is encouraged in the review process for new critical experiment requests sponsored by the US Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP)to demonstrate that the proposed experiment will satisfy the identified data need. Many individuals participate in this process, but many analysts have not received proper training in the use of the TSUNAMI tools. The adjoint perturbation theory used to calculate sensitivities is not typically included in nuclear engineering curricula, leaving inexperienced engineers particularly at risk for incorrect use of the tools.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SNAPSHOT: A MODERN, SUSTAINABLE HOLDUP MEASUREMENT SYSTEM

SNAPSHOT is a software platform designed to eventually replace Holdup Measurement System 4 (HMS 4), which is the current state-of-the-art for acquisition and analysis of nondestructive assay measurement data for in situ nuclear materials, holdup, in support of criticality safety and material control and accounting. HMS 4 is over 10 years old and is currently unsustainable due to hardware and software incompatibilities that have arisen from advances in detector electronics, primarily updates to multi-channel analyzers (MCAs), and both computer and handheld operating systems. SNAPSHOT is a complete redesign of HMS 4 that addresses the issue of compatibility with modern MCAs and operating systems and that is designed with a flexible architecture to support long-term sustainability. It also provides an updated and more user friendly interface and is being developed under an NQA 1 software quality assurance (SQA) program to facilitate site acceptance for safety-related applications. This paper provides an overview of the SNAPSHOT project including details of the software development process, the SQA program, and the architecture designed to support sustainability.

Rowe, Nathan C↗

Advancing Inverse Sensitivity/Uncertainty Methods for Nuclear Fuel Cycle Applications

The inverse sensitivity/uncertainty quantification (IS/UQ) method has recently been implemented in the Inverse Sensitivity/UnceRtainty Estimiator (INSURE) module of the AMPX system [1]. The IS/UQ method aims to quantify and prioritize the cross section measurements along with uncertainties needed to yield a given nuclear application(s) target response uncertainty, and doing this at a minimum cost. Since in some cases the extant uncertainties of the differential cross section data are already near the limits of the present-day state-of-the-art measurements, requiring significantly smaller uncertainties may be unrealistic. Therefore we have incorporated integral benchmark experiments (IBEs) data into the IS/UQ method using the generalized linear least-squares method, and have implemented it in the INSURE module. We show how the IS/UQ method could be applied to systematic and statistical uncertainties in a self-consistent way. We show how the IS/UQ method could be used to optimize uncertainties of IBEs and differential cross section data simultaneously.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Upper Subcritical Calculations Based on Correlated Data

The American National Standards Institute and American Nuclear Society standard for Validation of Neutron Transport Methods for Nuclear Criticality Safety Calculations defines the upper subcritical limit (USL) as “a limit on the calculated k-effective value established to ensure that conditions calculated to be subcritical will actually be subcritical.” Often, USL calculations are based on statistical techniques that infer information about a nuclear system of interest from a set of known/well-characterized similar systems. The work in this paper is part of an active area of research to investigate the way traditional trending analysis is used in the nuclear industry, and in particular, the research is assessing the impact of the underlying assumption that the experimental data being analyzed for USL calculations are statistically independent. In contrast, the multiple experiments typically used for USL calculations can be correlated because they are often performed at the same facilities using the same materials and measurement techniques. This paper addresses this issue by providing a set of statistical inference methods to calculate the bias and bias uncertainty based on the underlying assumption that the experimental data are correlated. Methods to quantify these correlations are the subject of a companion paper and will not be discussed here. The newly proposed USL methodology is based on the assumption that the integral experiments selected for use in the establishment of the USL are sufficiently applicable and that experimental correlations are known. Under the assumption of uncorrelated data, the new methods collapse directly to familiar USL equations currently used. We will demonstrate our proposed methods on real data and compare them to calculations of currently used methods such as USLSTATS and NUREG/CR-6698. Lastly, we will also demonstrate the effect experiment correlations can have on USL calculations.

42 ENGINEERING↗

Development and Testing of Neutron Cross Section Covariance Data for SCALE 6.2

Neutron cross-section covariance data are essential for many sensitivity/uncertainty and uncertainty quantification assessments performed both within the TSUNAMI suite and more broadly throughout the SCALE code system. The release of ENDF/B-VII.1 included a more complete set of neutron cross-section covariance data: these data form the basis for a new cross-section covariance library to be released in SCALE 6.2. A range of testing is conducted to investigate the properties of these covariance data and ensure that the data are reasonable. These tests include examination of the uncertainty in critical experiment benchmark model k eff values due to nuclear data uncertainties, as well as similarity assessments of irradiated pressurized water reactor (PWR) and boiling water reactor (BWR) fuel with suites of critical experiments. The contents of the new covariance library, the testing performed, and the behavior of the new covariance data are described in this paper. The neutron cross-section covariances can be combined with a sensitivity data file generated using the TSUNAMI suite of codes within SCALE to determine the uncertainty in system k eff caused by nuclear data uncertainties. The Verified, Archived Library of Inputs and Data (VALID) maintained at Oak Ridge National Laboratory (ORNL) contains over 400 critical experiment benchmark models, and sensitivity data are generated for each of these models. The nuclear data uncertainty in k eff is generated for each experiment, and the resulting uncertainties are tabulated and compared to the differences in measured and calculated results. The magnitude of the uncertainty for categories of nuclides (such as actinides, fission products, and structural materials) is calculated for irradiated PWR and BWR fuel to quantify the effect of covariance library changes between the SCALE 6.1 and 6.2 libraries. One of the primary applications of sensitivity/uncertainty methods within SCALE is the assessment of similarities between benchmark experiments and safety applications. This is described by a c k value for each experiment with each application. Several studies have analyzed typical c k values for a range of critical experiments compared with hypothetical irradiated fuel applications. The c k value is sensitive to the cross-section covariance data because the contribution of each nuclide is influenced by its uncertainty; large uncertainties indicate more likely bias sources and are thus given more weight. Changes in c k values resulting from different covariance data can be used to examine and assess underlying data changes. These comparisons are performed for PWR and BWR fuel in storage and transportation systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of the concrete shield compositions from the 2010 criticality accident alarm system benchmark experiments at the CEA Valduc SILENE facility

In October 2010, a series of benchmark experiments were conducted at the French Commissariat a l'Energie Atomique et aux Energies Alternatives (CEA) Valduc SILENE facility. These experiments were a joint effort between the United States Department of Energy Nuclear Criticality Safety Program and the CEA. The purpose of these experiments was to create three benchmarks for the verification and validation of radiation transport codes and evaluated nuclear data used in the analysis of criticality accident alarm systems. This series of experiments consisted of three single-pulsed experiments with the SILENE reactor. For the first experiment, the reactor was bare (unshielded), whereas in the second and third experiments, it was shielded by lead and polyethylene, respectively. The polyethylene shield of the third experiment had a cadmium liner on its internal and external surfaces, which vertically was located near the fuel region of SILENE. During each experiment, several neutron activation foils and thermoluminescent dosimeters (TLDs) were placed around the reactor. Nearly half of the foils and TLDs had additional high-density magnetite concrete, high-density barite concrete, standard concrete, and/or BoroBond shields. CEA Saclay provided all the concrete, and the US Y-12 National Security Complex provided the BoroBond. Measurement data from the experiments were published at the 2011 International Conference on Nuclear Criticality (ICNC 2011) and the 2013 Nuclear Criticality Safety Division (NCSD 2013) topical meeting. Preliminary computational results for the first experiment were presented in the ICNC 2011 paper, which showed poor agreement between the computational results and the measured values of the foils shielded by concrete. Recently the hydrogen content, boron content, and density of these concrete shields were further investigated within the constraints of the previously available data. New computational results for the first experiment are now available that show much better agreement with the measured values.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Tungsten Neutron Cross Sections in the Resolved Resonance Regions

We generated a preliminary set of resonance parameters for 182-184,186W in the neutron energy range of thermal up to several keV. The evaluation methodology uses the Reich-Moore approximation to t, with the R-matrix code SAMMY, the high-resolution measurements performed in 2010 and 2012 at the GEel LINear Accelerator (GELINA) facility. Particularly for 183W, the transmission data and the capture cross sections calculated with the set of resonance parameters are compared with the experimental values, and some of the average properties of the resonance parameters are discussed. In the analyzed energy range, this work almost doubles the existing resolved resonance evaluations in the ENDF/B-VII.1 library. The analysis of the performance of the calculated cross sections based on criticality benchmarks is still in progress and it is only briefly discussed.

Pigni, Marco T↗

Inverse Sensitivity/Uncertainty Methods Development for Nuclear Fuel Cycle Applications

The Standardized Computer Analyses for Licensing Evaluation (SCALE) software package developed at the Oak Ridge National Laboratory includes codes that propagate uncertainties available in the nuclear data libraries to compute uncertainties in nuclear application performance parameters (responses). We report on our recently commenced eorts to extend this capability to develop an inverse sen- sitivity/uncertainty (IS/U) methodology that identies the improvements in nuclear data that are needed to compute application responses within prescribed tolerances, while minimizing the cost of such data improvements. We report on our progress to date and present a simple test case for our method. Our methodology is directly applicable to thermal and intermediate neutron energy systems because it addresses the implicit neutron resonance self-shielding eects that are essential to accurate modeling of thermal and intermediate systems. This methodology is likely to increase the eciency of nuclear data eorts.

Arbanas, Goran↗

Enhancements in Continuous-Energy Monte Carlo Capabilities for SCALE 6.2

SCALE is a widely used suite of tools for nuclear systems modeling and simulation that provides comprehensive, verified and validated, user-friendly capabilities for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. For more than 30 years, regulators, industry, and research institutions around the world have used SCALE for nuclear safety analysis and design. SCALE provides a plug-and-play framework that includes three deterministic and three Monte Carlo radiation transport solvers that are selected based on the desired solution. SCALE includes the latest nuclear data libraries for continuous-energy and multigroup radiation transport as well as activation, depletion, and decay calculations. SCALE s graphical user interfaces assist with accurate system modeling, visualization, and convenient access to desired results. SCALE 6.2 provides several new capabilities and significant improvements in many existing features, especially with expanded continuous-energy Monte Carlo capabilities for criticality safety, shielding, depletion, sensitivity and uncertainty analysis, and improved fidelity in nuclear data libraries. A brief overview of SCALE capabilities is provided with emphasis on new features for SCALE 6.2.

Continuous-Energy↗

Enhancements in Continuous-Energy Monte Carlo Capabilities in SCALE

Monte Carlo tools in SCALE are commonly used in criticality safety calculations as well as sensitivity and uncertainty analysis, depletion, and criticality alarm system analyses. Recent improvements in the continuous-energy data generated by the AMPX code system and significant advancements in the continuous-energy treatment in the KENO Monte Carlo eigenvalue codes facilitate the use of SCALE Monte Carlo codes to model geometrically complex systems with enhanced solution fidelity. The addition of continuous-energy treatment to the SCALE Monaco code, which can be used with automatic variance reduction in the hybrid MAVRIC sequence, provides significant enhancements, especially for criticality alarm system modeling. This paper describes some of the advancements in continuous-energy Monte Carlo codes within the SCALE code system.

97 MATHEMATICS AND COMPUTING↗

183W Resonance Parameter Evaluation in the Neutron Energy Range Up to 5 keV

We generated a preliminary set of resonance parameters for {sup 183}W in the neutron energy range of thermal up to 5 keV. In the analyzed energy range, this work represents a significant improvement over the current resonance evaluation in the ENDF/B-VII.1 library limited up to 2.2 keV. The evaluation methodology uses the Reich-Moore approximation to fit, with the R-matrix code SAMMY, the high-resolution measurements performed in 2007 at the GEel LINear Accelerator (GELINA) facility. The transmission data and the capture cross sections calculated with the set of resonance parameters are compared with the experimental values, and the average properties of the resonance parameters are discussed.

43 PARTICLE ACCELERATORS↗