Engineering Papers⌕ Search

Engineering topics

Dungee, Ryan

Publications and source records attributed to Dungee, Ryan.

High-resolution SOFIA/EXES Spectroscopy of SO2 Gas in the Massive Young Stellar Object MonR2 IRS3: Implications for the Sulfur Budget

Sulfur has been observed to be severely depleted in dense clouds leading to uncertainty in the molecules that contain it and the chemistry behind their evolution. Here, we aim to shed light on the sulfur chemistry in young stellar objects (YSOs) by using high-resolution infrared spectroscopy of absorption by the ν3 rovibrational band of SO2 obtained with the Echelon-Cross-Echelle Spectrograph on the Stratospheric Observatory for Infrared Astronomy. Using local thermodynamic equilibrium models we derive physical parameters for the SO2 gas in the massive YSO MonR2 IRS3. This yields a SO2/H abundance lower limit of 5.6 ± 0.5 × 10(exp -7), or >4% of the cosmic sulfur budget, and an intrinsic line width (Doppler parameter) of b < 3.20 km s(exp -1). The small line widths and high temperature (Tex = 234 ± 15 K) locate the gas in a relatively quiescent region near the YSO, presumably in the hot core where ices have evaporated. This sublimation unlocks a volatile sulfur reservoir (e.g., sulfur allotropes as detected abundantly in comet 67P/Churyumov–Gerasimenko), which is followed by SO2 formation by warm, dense gas-phase chemistry. The narrowness of the lines makes formation of SO2 from sulfur sputtered off grains in shocks less likely toward MonR2 IRS3.

Infrared ISM↗

Project Summary

Telescope surveys have given us a great deal of information about our universe, but the images they capture carry with them an inherent limitation. The question then is how do we take this information to the next level? The answer: the Dark Energy Spectroscopic Instrument (DESI). DESI is an instrument that will measure the distance to tens of millions of galaxies in our night sky. This information can be combined with already existing images to construct a three dimensional map of our universe providing a great deal of new opportunities for cosmological research.

47 OTHER INSTRUMENTATION↗

Quantifying the Performance of Charge-Coupled Devices in Ambient Conditions - Oral presentation [Slides]

Telescope surveys have given us a great deal of information about our universe, but the images they capture carry with them an inherent limitation. The question then is how do we take this information to the next level? The answer: the Dark Energy Spectroscopic Instrument (DESI). DESI is an instrument that will measure the distance to tens of millions of galaxies in our night sky. This information can be combined with already existing images to construct a three dimensional map of our universe providing a great deal of new opportunities for cosmological research. The DESI guidance system consists of 10 detectors called charge-coupled devices (CCDs). Each CCD is made of silicon atoms that emit electrons when struck with light, the electrons are counted and then used to reconstruct an image. But, CCDs suffer from an issue known as ‘dark current’ which are false counts that come from thermal motions of the silicon atoms. This is particularly problematic since they contribute to the uncertainty of a measurement without contributing to our signal. This causes a drop in the signal to noise ratio, a value that needs to be maximized in order to meet DESI’s high precision requirements. This summer was spent ensuring the DESI guidance system would meet its specifications. Data was collected using a CCD of the same type that would be used on DESI and the effectiveness of dark current removal was tested. Exposures were taken for a wide range of temperatures and exposure lengths and a number of dark current removal methods were implemented. While further testing is required, the initial results are quite promising and the DESI guidance system is on track to meet its specifications

47 OTHER INSTRUMENTATION↗

Testing an e2v CCD230-42 Sensor for Dark Current Performance at Ambient Temperatures (Final Paper)

The design of the Guidance Focus and Alignment (GFA) system for the Dark Energy Spectroscopic Instrument (DESI) project calls for a set of charge-coupled devices (CCDs) which operate at ambient temperature. Here we assess the performance of these CCDs under such conditions. Data was collected from –21°C to 28°C and used to determine the effect of temperature on the effectiveness of dark current subtraction. Comparing the dark current uncertainty to our expected signal has shown that the DESI design specifications will be met without need for significant changes.

47 OTHER INSTRUMENTATION↗