Failure Analysis of Gas Spray Atomization Crucible Materials

An attempted induction melt for gas spray atomization of a Pd alloy at Savannah River National Laboratory experienced a series of faulty thermocouple readings leading to failure of multiple alumina ceramic components and the loss of the metal charge. The spherical powders are used in research and development efforts for hydrogen storage applications. The failure of the thermocouples led to high operating temperatures exceeding the expected operating temperatures. Estimated temperatures of the liquid metal were established by the comparison of the radio frequency power output and multiple temperature readings and determined to have exceeded the functional temperature range of the alumina components. Failure analyses of the event included characterization of the components using visual observation and X-Ray computed tomography of the frozen ingot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wire Arc Additive Manufacturing

Project highlight. This project designs and implements a new additive manufacturing capability at Savannah River National Laboratory. Wire Arc Additive Manufacturing is an Advanced Manufacturing technology that enables materials and energy savings by producing materials that are in near net shapes to minimize material losses compared to conventional forging and machining techniques. Wire arc additive manufacturing is an evolving technology that can be used to fabricate large components with significantly less materials waste than conventional processing. This project includes an engineering model, an aspect that is largely overlooked in the Additive Manufacturing modeling work where the emphasis has been on mechanistic and microscopic modeling, to estimate the residual stresses and distortions. The Abaqus Weld Interface software coupled with user subroutines in Fortran enable the local cooling rates to be estimated to provide a coarse scale model for the secondary dendrite arm spacing, a parameter useful to estimate mechanical properties.

36 MATERIALS SCIENCE↗

Test Methods for Cementitious Seal Materials for Borehole Disposal - 17352

The Nuclear and Energy Research Institute (IPEN-CNEN/SP) in Sao Paulo-Brazil, is considering borehole disposal of disused sealed radioactive sources (DSRS), which were used in smoke detectors, lightning arresters, radiotherapy, industrial gauges, irradiators, and other applications. The current IPEN concept of borehole is a modified BOSS system developed by the International Atomic Energy Agency (IAEA). It differs from the IAEA's design in that the disposal zone is below 300 m, and the DSRS are placed directly in the disposal packages constituted of stainless steel containers with 1.5 L capacity. A borehole drilled through sediment and granite, stabilized with stainless steel casing and cement grout is proposed for the conceptual model. Standard cement-material test methods and performance specific test methods, including accelerated aging methods, are needed for modeling the performance of the candidate cementitious grouts. A cross-disciplinary team from the USA Savannah River National laboratory is providing technical assistance to IPEN in this performance assessment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Contributions of stress and oxidation on the formation of whiskers in Pb-free solders

Understanding the environmental factors influencing formation of tin whiskers on electrodeposited lead free, tin coatings over copper (or copper containing) substrates is the topic of this study . An interim report* summarized initial observations as to the role of stress and oxide formation on whisker growth. From the initial results, two main areas were chosen to be the focus of additional research: the demonstration of effects of elastic stress state in the nucleation of whiskers and the confirmation of the effect of oxygen content in the formation of whiskers. Different levels of elastic stress were induced with the incorporation of a custom designed fixture that loaded the sample in a four-point bending configuration and were maintained in an environmental chamber under conditions deemed favorable for whisker growth. The effects of oxygen content were studied by aging substrates in gas vials of varying absolute pressure and different oxygen partial pressure.

36 MATERIALS SCIENCE↗