Isotopic Heterogeneity Imaged in a Uranium Fuel Pellet with Extreme Ultraviolet Laser Ablation and Ionization Time-of-Flight Mass Spectrometry

We use extreme ultraviolet laser ablation and ionization time-of-flight mass spectrometry (EUV TOF) to map uranium isotopic heterogeneity at the nanoscale (=100 nm). Using low-enriched uranium fuel pellets that were made by blending two isotopically distinct feedstocks, we show that EUV TOF can map the 235U/238U content in 100 nm-sized pixels. The two-dimensional (2D) isotope maps reveal U ratio variations in sub-microscale to =1 µm areas of the pellet that had not been fully exposed by microscale or bulk mass spectrometry analyses. Compared to the ratio distribution measured in a homogeneous U reference material, the ratios in the enriched pellet follow a ~3× wider distribution. These results indicate U heterogeneity in the fuel pellet from incomplete blending of the different source materials. EUV TOF results agree well with those obtained on the same enriched pellets by nanoscale secondary ionization mass spectrometry (NanoSIMS), which reveals a comparable U isotope ratio distribution at the same spatial scale. EUV TOF’s ability to assess and map isotopic heterogeneity at the nanoscale makes it a promising tool in fields such as nuclear forensics, geochemistry, and biology that could benefit from uncovering sub-microscale sources of chemical modifications.

Rush, Lydia A.↗

Characterization of extreme ultraviolet laser ablation mass spectrometry for actinide trace analysis and nanoscale isotopic imaging

The purpose of this research was to characterize Extreme Ultraviolet Time-of-Flight (EUV TOF) Laser Ablation Mass Spectrometry for high spatial resolution elemental and isotopic analysis. We compare EUV TOF results with Secondary Ionization Mass Spectrometry (SIMS) to orient the EUV TOF method within the overall field of analytical mass spectrometry. Using the well-characterized NIST 61x glasses, we show that the EUV ionization approach produces relatively few molecular ion interferences in comparison to TOF SIMS. We demonstrate that the ratio of element ion to element oxide ion is adjustable with EUV laser pulse energy and that the EUV TOF instrument has a sample utilization efficiency of 0.014%. The EUV TOF system also achieves a lateral resolution of 80 nm and we demonstrate this lateral resolution with isotopic imaging of closely spaced particles or uranium isotopic standard materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of Uranyl Minerals Using Oxygen K-Edge X Ray Absorption Spectroscopy

Uranium analysis is consistently needed throughout the fuel cycle, from mining to fuel fabrication to environmental monitoring. Although most of the world’s uranium is immobilized as pitchblende or uraninite, there exists a plethora of secondary uranium minerals, nearly all of which contain the uranyl cation. Analysis of uranyl compounds can provide clues as to a sample’s facility of origin and chemical history. X-ray absorption spectroscopy is one technique that could enhance our ability to identify uranium minerals. Although there is limited chemical information to be gained from the uranium X-ray absorption edges, recent studies have successfully used ligand NEXAFS to study the physical chemistry of various uranium compounds. This study extends the use of ligand NEXAFS to analyze a suite of uranium minerals. We find that major classes of uranyl compounds (carbonate, oxyhydroxide, silicate, and phosphate) exhibit characteristic lineshapes in the oxygen K-edge absorption spectra. As a result, this work establishes a library of reference spectra that can be used to classify unknown uranyl minerals.

Environmental Molecular Sciences Laboratory↗

The influence of ns- and fs-LA plume local conditions on the performance of a combined LIBS/LA-ICP-MS sensor

Both laser-induced breakdown spectroscopy (LIBS) and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) are well-established analytical techniques with their own unique advantages and disadvantages. The combination of the two analytical methods is a very promising way to overcome the challenges faced by each method individually. We made a comprehensive comparison of local plasma conditions between nanosecond (ns) and femtosecond (fs) laser ablation (LA) sources in a combined LIBS and LA-ICP-MS system. The optical emission spectra and ICP-MS signal were recorded simultaneously for both ns- and fs-LA and figures of merit of the system were analyzed. Characterization of the plasma was conducted by evaluating temperature and density of the plume under various irradiation conditions using optical emission spectroscopy, and correlations to ns- and fs-LIBS and LA-ICP-MS signal were made. The present study is very useful for providing conditions for a multimodal system as well as giving insight into how laser ablation plume parameters are related to LA-ICP-MS and LIBS results for both ns- and fs-LA.

LaHaye, Nicole L.↗

Covalency in Oxidized Uranium

Using X-­-ray Emission Spectroscopy (XES) and Absorption Spectroscopy (XAS), it has been possible to directly access the states in the unoccupied conduction bands that are involved with 5f and 6d covalency in oxidized Uranium. By varying the oxidizing agent, the degree of 5f covalency can be manipulated and monitored, for the first time clearly and irrevocably establishing the importance of 5f covalency in the electronic structure of the key nuclear fuel, uranium dioxide.

Tobin, James G.↗

Femtosecond Laser Ablation Multicollector ICPMS Analysis of Uranium Isotopes in NIST Glass

We have utilized femtosecond laser ablation coupled to multi-collector inductively couple plasma mass spectrometry to measure the uranium isotopic content of NIST 61x (x=0,2,4,6) glasses. The uranium content of these glasses is a linear two-component mixing between isotopically natural uranium and the isotopically depleted spike used in preparing the glasses. Laser ablation results match extremely well, generally within a few ppm, with solution analysis following sample dissolution and chemical separation. In addition to isotopic data, sample utilization efficiency measurements indicate that over 1% of ablated uranium atoms reach a mass spectrometer detector, making this technique extremely efficient. Laser sampling also allows for spatial analysis and our data indicate that rare uranium concentration inhomogeneities exist in NIST 616 glass.

Duffin, Andrew M.↗

High Precision Isotopic Analysis of Actinide Bearing Materials: Performance of a New Generation of Purpose Built Actinide Multi-Collector ICPMS Instruments

Recently, a new class of multi-collector inductively coupled plasma mass spectrometers (MC-ICPMS) has been introduced commercially that includes detector arrays purpose built for actinide measurements. These detector arrays significantly enhance the data quality possible for applications encountered in nuclear forensics. Two such instruments are described in this paper, the NeptunePlusTM, developed by Thermo-Fisher (Bremen, Germany), and the NuPlasma2, developed by Nu Instruments (Wrexham, UK). Research results are presented that have been obtained by the authors using the first commercial NeptunePlusTM. This paper also presents performance characteristics and results for traditional liquid introduction, including a means for ultra-trace detection via electrochemical separation prior to solution nebulization, as well as solid sample introduction with femtosecond-laser ablation. We also discuss the advantages and limitations of the current systems for detection of the transient signals associated with these two methods for introducing sample into the plasma.

electrochemical separation↗

Isotopic Analysis of Uranium in NIST SRM Glass by Femtosecond Laser Ablation

We employed femtosecond Laser Ablation Multicollector Inductively Coupled Mass Spectrometry for the 11 determination of uranium isotope ratios in a series of standard reference material glasses (NIST 610, 612, 614, and 12 616). This uranium concentration in this series of SRM glasses is a combination of isotopically natural uranium in 13 the materials used to make the glass matrix and isotopically depleted uranium added to increase the uranium 14 elemental concentration across the series. Results for NIST 610 are in excellent agreement with literature values. 15 However, other than atom percent 235U, little information is available for the remaining glasses. We present atom 16 percent and isotope ratios for 234U, 235U, 236U, and 238U for all four glasses. Our results show deviations from the 17 certificate values for the atom percent 235U, indicating the need for further examination of the uranium isotopes in 18 NIST 610-616. Our results are fully consistent with a two isotopic component mixing between the depleted 19 uranium spike and natural uranium in the bulk glass.

Duffin, Andrew M.↗

Femtosecond laser ablation particle introduction to a liquid sampling-atmospheric pressure glow discharge ionization source

This work describes the use of a compact, liquid sampling – atmospheric pressure glow discharge (LS-APGD) ionization source to ionize metal particles within a laser ablation aerosol. Mass analysis was performed with a Thermo Scientific Exactive Mass Spectrometer which utilizes an orbitrap mass analyzer capable of producing mass resolution exceeding M/ΔM > 160,000. The LS-APGD source generates a low-power plasma between the surface of an electrolytic solution flowing at several µl min-1 through a fused silica capillary and a counter electrode consisting of a stainless steel capillary employed to deliver the laser ablation particles into the plasma. Sample particles of approximately 100 nm were generated with an Applied Spectra femtosecond laser located remotely and transported through 25 meters of polyurethane tubing by means of argon carrier gas. Samples consisted of an oxygen free copper shard, a disk of solder, and a one-cent U.S. coin. Analyte signal onset was readily detectable relative to the background signal produced by the carrier gas alone. The high mass resolution capability of the orbitrap mass spectrometer was demonstrated on the solder sample with resolution exceeding 90,000 for Pb and 160,000 for Cu. In addition, results from a laser ablation depth-profiling experiment of a one cent coin revealed retention of the relative locations of the ~10 µm copper cladding and zinc rich bulk layers.