Magnetron R&Ds for High Efficiency CW RF Sources of Particle Accelerators
A proof of principle experiment carried out at JLab's magnetron R&D test stand has demonstrated a -25dB injection signal to phase lock a 2.45GHz 1.2kW CW magnetron within 2.1 Hz of root mean square deviation (RMSD) value with the optimization of magnetic field trimming of ±25% in order to overcome the frequency pushing of more than 4MHz in the RF power output range of 45-100%. In addition, a test stand for a newly built 1497 MHz, 13kW, CW magnetron prototype is ready for the high power injection test with outcome aimed for the CEBAF klystron replacement. Based on these R&D results, a 915MHz, 2?75kW CW commercial heating type magnetron system is being developed as high efficiency (>80%) RF source to drive an electron linac for industrial applications.