Engineering Papers⌕ Search

Engineering topics

Doyle, Barney Lee

Publications and source records attributed to Doyle, Barney Lee.

At least 19 records

The new Pulsed Power Electron Gun (PPEG) at Sandia National Labs*

There is interest in increasing the size and range of the electron beams while maintaining their high dose rate. To accomplish this a Pulsed Power Electron Gun (PPEG) has been developed based around a pulsed (30ns) 300 kV Marx Generator (Applied Physical Electronics L.C.).

Vizkelethy, Gyorgy↗

Deciphering a removed text on a 16th c. centrepiece: The benefits of using AGLAEMap and AXSIA to process PIXE maps.

In the field of archaeometry, it is not uncommon to be presented with art objects that contain inscriptions, signatures and other writings that are nearly impossible to read. Scanned microbeam PIXE offers an attractive approach to attack this problem, but even then the distribution of characteristic X-rays of the element(s) used in these writings can remain illegible. We show in this paper that two methods were used to reveal the inscription: first the use of a GUPIXWin, TRAUPIXE and AGLAEMap software suite enables to make quantitative analysis of each pixel, to visualize the results and to select X-ray peaks that could enable to distinguish letters. Then, the Automated eXpert Spectral Image Analysis (AXSIA) program developed at Sandia, which analyzes the x-ray intensity vs. Energy and (X, Y) position “datacubes”, was used to factor the datacube into 1) principle component spectral shapes and 2) the weighting images of these components. The specimen selected for this study was a silver plaque representing a scroll from the so-called “MerkelscheTafelaufsatz,” a centrepiece made by the Nuremberg goldsmith Wenzel Jamnitzer in 1549. X-ray radiography of the plaque shows lines of different silver thicknesses, meaning that a text has been removed. The PIXE analysis used a 3-MeV proton beam focused to 50μm and scanned across the sample on different areas of interest of several cm². This analysis showed major elements of Cu and Ag, and minor elements such as Pb, Au, Hg. X-ray intensity maps were then made by setting windows on the various x-ray peaks but the writing on the centrepiece was not revealed even if the map of Cu after data treatment at AGLAE enabled to distinguish some letters. The AXSIA program enabled to factor two main spectral shapes from the datacube that were quite similar and involved virtually all of the X-rays being generated. Nevertheless, small differences between these factors were observed for the Cu K X-rays, Pb, Bi and Au L X-rays. The plot of the factor with the highest Au signal gave also information on the shape of some letters. The comparison of the results obtained by the two methods shows that they both drastically improve the resolution and contrast of such writings and that each of the method can also bring different information on the composition and thus the techniques used for the writing.

AGLAEMap↗

Optimization of a low noise detection circuit for probing the structure of damage cascades with IBIC

Optimal detector / pre-amplifier combinations have been identified for the use of light ion IBIC (ion beam induced charge) to probe the physical structure of electrically active defects in damage cascades caused by heavy ion implantation. The ideal detector must have a sufficiently thin dead layer that incident ions will produce the majority of damage cascades in the depletion region of the detector rather than the dead layer. Detector and circuit noise must be low enough to detect the implantation of a single heavy ion as well as the decrease in the light ion IBIC signal caused by Shockley-Read-Hall recombination when the beam scans regions of the detector damaged by the heavy ion. The IBIC signals from three detectors irradiated with 750 keV He⁺ ions are measured with commercial and bespoke charge sensitive pre-amplifiers to identify the combination with the lowest noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Outstanding conference paper award 2014 IEEE nuclear and space radiation effects conference

The recipients of the 2014 NSREC Outstanding Conference Paper Award are Nathaniel A. Dodds, James R. Schwank, Marty R. Shaneyfelt, Paul E. Dodd, Barney L. Doyle, Michael Trinczek, Ewart W. Blackmore, Kenneth P. Rodbell, Michael S. Gordon, Robert A. Reed, Jonathan A. Pellish, Kenneth A. LaBel, Paul W. Marshall, Scot E. Swanson, Gyorgy Vizkelethy, Stuart Van Deusen, Frederick W. Sexton, and M. John Martinez, for their paper entitled "Hardness Assurance for Proton Direct Ionization-Induced SEEs Using a High-Energy Proton Beam." For older CMOS technologies, protons could only cause single-event effects (SEEs) through nuclear interactions. Numerous recent studies on 90 nm and newer CMOS technologies have shown that protons can also cause SEEs through direct ionization. Furthermore, this paper develops and demonstrates an accurate and practical method for predicting the error rate caused by proton direct ionization (PDI).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗