Engineering PapersSearch

Engineering topics

Douglas, Susanne

Publications and source records attributed to Douglas, Susanne.

Micro Electron MicroProbe and Sample Analyzer

A proposed, low-power, backpack-sized instrument, denoted the micro electron microprobe and sample analyzer (MEMSA), would serve as a means of rapidly performing high-resolution microscopy and energy-dispersive x-ray spectroscopy (EDX) of soil, dust, and rock particles in the field. The MEMSA would be similar to an environmental scanning electron microscope (ESEM) but would be much smaller and designed specifically for field use in studying effects of geological alteration at the micrometer scale. Like an ESEM, the MEMSA could be used to examine uncoated, electrically nonconductive specimens. In addition to the difference in size, other significant differences between the MEMSA and an ESEM lie in the mode of scanning and the nature of the electron source.

Manohara, Harish

MEMS-Based Micro Instruments for In-Situ Planetary Exploration

NASA's planetary exploration strategy is primarily targeted to the detection of extant or extinct signs of life. Thus, the agency is moving towards more in-situ landed missions as evidenced by the recent, successful demonstration of twin Mars Exploration Rovers. Also, future robotic exploration platforms are expected to evolve towards sophisticated analytical laboratories composed of multi-instrument suites. MEMS technology is very attractive for in-situ planetary exploration because of the promise of a diverse and capable set of advanced, low mass and low-power devices and instruments. At JPL, we are exploiting this diversity of MEMS for the development of a new class of miniaturized instruments for planetary exploration. In particular, two examples of this approach are the development of an Electron Luminescence X-ray Spectrometer (ELXS), and a Force-Detected Nuclear Magnetic Resonance (FDNMR) Spectrometer.

micro instruments

Atmospheric Electron-Induced X-Ray Spectrometer (AEXS) Development

This paper describes the progress in the development of the so-called Atmospheric Electron X-ray Spectrometer (AEXS) instrument in our laboratory at JPL. The AEXS is a novel miniature instrument concept based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam, for non-destructive evaluation of surfaces of samples in situ, in planetary ambient atmosphere. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum within the AEXS electron source from the outside ambient atmosphere. By using a focused electron beam, the impinging electrons on samples in the external atmosphere excite XRF spectra from the irradiated spots with high-to-medium spatial resolution. The XRF spectra are analyzed using an energy-dispersive detector to determine surface elemental composition. The use of high- intensity electron beam results in rapid spectrum acquisition (several minutes), and consequently low energy consumption (several tens of Joules) per acquired XRF spectrum in comparison to similar portable instruments.

X-ray fluorescence (XRF)

High Resolution Chemical Study of ALH84001

We have studied the chemistry of a sample of the SNC meteorite ALH84001 using an environmental scanning electron microscope (ESEM) with an energy dispersive chemical analytical detector and a focused ion beam secondary ion mass spectrometer (FIB-SIMS). Here we present the chemical data, both spectra and images, from two techniques that do not require sample preparation with a conductive coating, thus eliminating the possibility of preparation-induced textural artifacts. The FIB-SIMS instrument includes a column optimized for SEM with a quadrupole type mass spectrometer. Its spatial and spectral resolution are 20 nm and 0.4 AMU, respectively. The spatial resolution of the ESEM for chemical analysis is about 100 nm. Limits of detection for both instruments are mass dependent. Both the ESEM and the FIB-SIMS instrument revealed contrasting surficial features; crumbled, weathered appearance of the matrix in some regions as well as a rather ubiquitous presence of euhedral halite crystals, often associated with cracks or holes in the surface of the rock. Other halogen elements present in the vicinity of the NaCl crystals include K and Br. In this report, elemental inventories are shown as mass spectra and as X-ray maps.

Conrad, Pamela G.

Organization of P, S, and Fe Inclusions in a Freshwater Magnetococcus

Magnetotactic bacteria are a heterogeneous group of motile, mainly aquatic procaryotes that align and swim along geomagnetic field lines. They are of interest to astrobiologists because of the magnetite crystals found in the Mars meteorite ALH84001 which share many characteristics with the magnetite produced intracellularly by magnetotactic bacteria. These bacteria are diverse morphologically, physiologically and phylogenetically, sharing a few key characteristics: 1) the presence of intracellular membrane-bound magnetic crystals (magnetosomes), usually but not always arranged in chains; 2) motility by means of flagella; and 3) microaerophillic or anaerobic physiology. The bilophotrichous (having two flagella bundles) magnetotactic cocci (MC) are ubiquitous in aquatic habitats but have proven extremely difficult to cultivate. Because only several marine strains have been isolated and grown in axenic culture, little is known about the physiology and the biogeochemical roles of the MC. We studied the composition and distribution of intracellular structures in an uncultured MC, designated ARB-1. To do this, a combination of light microscopy, environmental scanning electron microscopy (ESEM), transmission electron microscopy (TEM) and energy dispersive X-ray spectroscopy (EDS) were used. Cells of ARB-1 were separated from sediments collected from Baldwin Lake (Los Angeles Arboretum, Arcadia, CA). They are large spherical to oblate spheroidal Gram-negative cells, ranging from 1 to 4 micrometers along the maximum dimension, which is perpendicular to the direction of swimming. Cells have two large phosphorus-containing inclusions that comprise a large percentage of the cell volume. Many smaller sulfur inclusions are located at the convex end of the cell. Most of the cellular Fe is present in the magnetosomes. These may be arranged as a clump at the concave end of the cell, near the two flagella bundles, or as chains, or as both a clump and chains. The magnetosomes were identified as magnetite (Fe3O4) by selected area electron diffraction (SAED) and high resolution TEM. We saw a trend between cell size and organization of the magnetosomes. Smaller, more spherical cells were more likely to have chains than were larger, more oblate cells. This may indicate different populations of cells, or it may be attributed to variations in cell growth cycle. The size distribution (length) of magnetosomes in chains was similar to that of magnetosomes in clusters, except that there was a larger size range for clustered magnetosomes. Magnetosomes from ARB-1 cells average 82 nm in length. If plotted on a graph of length as a function of aspect ratio, they fall within the single domain region of the plot. If compared with the size distributions of magnetite from ALH84001 and magnetosomes from the cultured magnetotactic vibrio MV-1, the magnetites produced by ARB-1 cells are, on average, larger and have a wider range of aspect ratio. ARB-1 cells have a specific organization of the P, S, and Fe inclusions. The P inclusions always occupy the majority of the cell volume and separate the S inclusions from the disorganized clumps of magnetosomes and the flagella bundles. The P inclusions may contain polyphosphate, which could play several roles in motility, adaptation to stress, growth and division, buoyancy, and energy. The S inclusions might be a way to store S, a potential energy source, when the cells move from sulfide to oxygen zones. The consistency of P, S, and Fe organization in ARB-1 cells suggests that these inclusions have some specific and interactive functions.

Cox, Lea