Engineering Papers⌕ Search

Engineering topics

Douglas, David

Publications and source records attributed to Douglas, David.

At least 19 records

Design and operation of a windowless gas target internal to a solenoidal magnet for use with a megawatt electron beam

A windowless hydrogen gas target of nominal thickness 10 19 cm -2 is an essential component of the DarkLight experiment, which is designed to utilize the megawatt electron beam at an Energy Recovery Linac (ERL). The design of such a target is challenging because the pressure drops by many orders of magnitude between the central, high-density section of the target and the surrounding beamline, resulting in laminar, transitional, and finally molecular flow regimes. The target system was assembled and operated at Jefferson Lab’s Low Energy Recirculator Facility (LERF) in 2016, and subsequently underwent several revisions and calibration tests at MIT Bates in 2017. The system at dynamic equilibrium was simulated in COMSOL to provide a better understanding of its optimal operation at other working points. We have determined that a windowless gas target with sufficiently high density for DarkLight’s experimental needs is feasible in an ERL environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesizing radioisotopes using an energy recovery linac

An apparatus and method for the production of radioisotopes utilizing an energy recovery linac. The ERL system is composed of an electron beam source, multiple superconducting radio frequency cavities operating at 4.5 K, a thin radiator, a target material, and a beam dump. The accompanying method discloses the use of the ERL system to generate desired radioisotopes via target interaction with bremsstrahlung photons while allowing recovery of a substantial portion of the electron beam energy before the beam is extracted to the beam dump.

Areti, Hari↗

Control of Coherent Synchrotron Radiation Effects During Recirculation with Bunch Compression

Studies of beam quality preservation during recirculation* have been extended to generate a design of an arc providing bunch compression with positive momentum compaction** and control of both incoherent and coherent synchrotron radiation (ISR and CSR) effects using the optics balance methods of diMitri et al.+. In addition, the arc/compressor generates very little micro-bunching gain. We detail the beam dynamical basis for the design, discuss the design process, give an example solution, and provide simulations of ISR and CSR effects. Reference will be made to a complete analysis of micro-bunching effects++. * D. Douglas et al., these proceedings ** S. Benson et al., these proceedings + S. diMitri et al., Phys. Rev. Lett. 110, 014801, 2 January 2013 ++ C.Y. Tsai et al., these proceedings This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Douglas, David↗

CONTROL OF SYNCHROTRON RADIATION EFFECTS DURING RECIRCULATION

We use results by Di Mitri et al. [1] as the basis of a method for suppression of synchrotron-radiation-driven beam quality degradation during recirculation. Use of second-order achromatic superperiodic recirculation transport based on individually isochronous and achromatic superperiods of low-quantum-excitation lattices is found to provide control of both emittance degradation from coherent synchrotron radiation (CSR) and microbunching instability (?BI) gain. Use of such low excitation lattices and choice of sufficiently large bend radius also insures incoherent synchrotron radiation (ISR) driven effects are well-managed.

Douglas, David↗

ELECTRON COOLING STUDY FOR MEIC

Electron cooling of the ion beams is one critical R&D to achieve high luminosities in JLab?s MEIC proposal. In the present MEIC design, a multi-staged cooling scheme is adapted, which includes DC electron cooling in the booster ring and bunched beam electron cooling in the collider ring at both the injection energy and the collision energy. We explored the feasibility of using both magnetized and non-magnetized electron beam for cooling, and concluded that a magnetized electron beam is necessary. Electron cooling simulation results for the newly updated MEIC design is also presented.

43 PARTICLE ACCELERATORS↗

Coherent Synchrotron Radiation in Energy Recovery Linacs

Collective beam effects, including coherent synchrotron radiation (CSR), have been studied on free-electron lasers (FELs). Here we will discuss a particular case of the CSR effects, that in energy-recovery linacs (ERLs). Special consideration is given to these machines because of their high average beam power and the architecture of the machine for energy recovery forces extreme bends. A recent study conducted on the JLab IR FEL looked at how CSR impacts both average energy and the energy spectrum of the beam. Such studies are important, both broadly, to the understanding of CSR and more specifically for a number of proposed ERL projects. A few proposed examples include the MEIC bunched beam cooler ERL design and ERL FELs for potential lithography purposes that would operate in the EUV range.

Douglas, David↗

Control of synchrotron radiation effects during recirculation with bunch compression

Studies of beam quality during recirculation have been extended to an arc providing bunch compression with positive momentum compaction. It controls both incoherent and coherent synchrotron radiation (ISR and CSR) using methods including optics balance and generates little microbunching gain. We detail the dynamical basis for the design, discuss the design process, give an example, and provide simulations of ISR and CSR effects. Reference will be made to a complete analysis of microbunching effects.

43 PARTICLE ACCELERATORS↗

DarkLight: A Search for Dark Forces at the Jefferson Laboratory Free-Electron Laser Facility

We give a short overview of the DarkLight detector concept which is designed to search for a heavy photon A' with a mass in the range 10 MeV/c^2 < m(A') < 90 MeV/c^2 and which decays to lepton pairs. We describe the intended operating environment, the Jefferson Laboratory free electon laser, and a way to extend DarkLight's reach using A' --> invisible decays.

Balewski, Jan↗

HIGH AVERAGE POWER UV FREE ELECTRON LASER EXPERIMENTS AT JLAB

Having produced 14 kW of average power at {approx}2 microns, JLAB has shifted its focus to the ultraviolet portion of the spectrum. This presentation will describe the JLab UV Demo FEL, present specifics of its driver ERL, and discuss the latest experimental results from FEL experiments and machine operations.

43 PARTICLE ACCELERATORS↗

X-ray Sources by Energy Recovered Linacs and Their Needed R&D

In this paper we review the current state of research on energy recovered linacs as drivers for future X-ray sources. For many types of user experiments, such sources may have substantial advantages compared to the workhorse sources of the present: high energy storage rings. Energy recovered linacs need to be improved beyond present experience in both energy and average current to support this application. To build an energy recovered linac based X-ray user facility presents many interesting challenges. We present summaries on the Research and Development (R&D) topics needed for full development of such a source, including the discussion at the Future Light Sources Workshop held in Gaithersberg, Maryland on September 15-17, 2009. A first iteration of an R&D plan is presented that is founded on the notion of building a set of succeedingly larger test accelerators exploring cathode physics, high average current injector physics, and beam recirculation and beam energy recovery at high average current. Our basic conclusion is that a reviewable design of such a source can be developed after an R&D period of reasonably short duration.

43 PARTICLE ACCELERATORS↗

DEMONSTRATION OF 3D EFFECTS WITH HIGH GAIN AND EFFICIENCY IN A UV FEL OSCILLATOR

We report on the performance of a high gain UV FEL oscillator operating on an energy recovery linac at Jefferson Lab. The high brightness of the electron beam leads to both gain and efficiency that cannot be reconciled with a one-dimensional model. Three-dimensional simulations do predict the performance with reasonable precision. Gain in excess of 100% per pass and an efficiency close to 1/2NW, where NW is the number of wiggler periods, is seen. The laser mirror tuning curves currently permit operation in the wavelength range of 438 to 362 nm. Another mirror set allows operation at longer wavelengths in the red with even higher gain and efficiency.

43 PARTICLE ACCELERATORS↗

Electron Beam Diagnostics Of The JLAB UV FEL

In this contribution we describe various systems and aspects of the electron beam diagnostics of the JLab UV FEL. The FEL is installed on a new bypass beam line at the existing 10 kW IR Upgrade FEL. Here, we describe a set of the following systems. A combination of OTR and phosphor viewers is used for measurements of the transverse beam profile, transverse emittance, and Twiss parameters. This system is also used for alignment of the optical cavity of the UV oscillator and to ensure the overlap between the electron beam and optical mode in the FEL wiggler. A system of beam position monitors equipped with log-amp based BPM electronics. Bunch length on the order of 120 fs RMS is measured with the help of a modified Martin-Puplett interferometer. The longitudinal transfer function measurement system is used to set up bunch compression in an optimal way, such that the LINAC RF curvature is compensated using only higher order magnetic elements of the beam transport. This set of diagnostic systems made a significant contribution in achieving first lasing of the FEL after only about 60 hours of beam operation.

43 PARTICLE ACCELERATORS↗

An Instrumentation Wish List for High Power/High Brightness ERLS

The advent of the energy recovering linac (ERL) brings with it the promise of linac-quality beams generated with near storage ring efficiency. This potential will not, however, be fulfilled without overcoming a number of technical and operational challenges. We will review the basics of ERL dynamics and operation, and give examples of idiosyncratic ERL behavior and requirements posing particular challenges from the perspective of diagnostics and instrumentation. Beam performance parameters anticipated in next-generation ERLs will be discussed, and a ?wish list? for the instrumentation of these machines presented.

Douglas, David↗