Engineering PapersSearch

Engineering topics

Dominguez, Alexandra

Publications and source records attributed to Dominguez, Alexandra.

Lynx X-Ray Observatory: An Overview

Lynx, one of the four strategic mission concepts under study for the 2020 Astrophysics Decadal Survey, provides leaps in capability over previous and planned x-ray missions and provides synergistic observations in the 2030s to a multitude of space- and ground-based observatories across all wavelengths. Lynx provides orders of magnitude improvement in sensitivity, on-axis subarcsecond imaging with arcsecond angular resolution over a large field of view, and high-resolution spectroscopy for point-like and extended sources in the 0.2- to 10-keV range. The Lynx architecture enables a broad range of unique and compelling science to be carried out mainly through a General Observer Program. This program is envisioned to include detecting the very first seed black holes, revealing the high-energy drivers of galaxy formation and evolution, and characterizing the mechanisms that govern stellar evolution and stellar ecosystems. The Lynx optics and science instruments are carefully designed to optimize the science capability and, when combined, form an exciting architecture that utilizes relatively mature technologies for a cost that is compatible with the projected NASA Astrophysics budget.

X-Ray Surveyor

Initial Jitter Analysis of Lynx, A Proposed Future Large Astrophysics Facility

Lynx, formerly known as the X-Ray surveyor, is one of the large strategic mission concepts being studied for input into the 2020 Astrophysics Decadal Survey. Lynx is the first future X-ray mission concept planning to match Chandra's angular-resolution and will combine this with very high throughput, large field of view, and high-resolution spectroscopy for point-like and extended sources. These ambitious performance requirements clearly merit early detailed engineering to demonstrate feasibility. An on-going structural dynamic analysis is being performed on the Lynx structural design to predict dynamic responses, jitter, to expected on-board vibrational disturbances. Applicable disturbance sources include a cryogenic pump, and six reaction wheels. The structural design, disturbances, analysis, and results are presented. Ultimately, responses will be compared to Lynx performance requirements as they relate to a system error budget.

Knight, J. Brent

The Lynx X-Ray Observatory: Concept Study Overview and Status

Lynx, one of four strategic mission concepts under study for the 2020 Astrophysics Decadal Survey, will provide leaps in capability over previous and planned X-ray missions, and will provide synergistic observations in the 2030s to a multitude of space- and ground-based observatories across all wavelengths. Lynx will have orders of magnitude improvement in sensitivity, on-axis sub-arcsecond imaging with arcsecond angular resolution over a large field of view, and high-resolution spectroscopy for point-like and extended sources. The Lynx architecture enables a broad range of unique and compelling science, to be carried out mainly through a General Observer Program. This Program is envisioned to include detecting the very first supermassive black holes, revealing the high-energy drivers of galaxy and structure formation, characterizing the mechanisms that govern stellar activity - including effects on planet habitability, and exploring the highest redshift galaxy clusters. An overview and status of the Lynx concept are summarized.

Gaskin, Jessica A.

Lynx Mission Concept Status

Lynx is a concept under study for prioritization in the 2020 Astrophysics Decadal Survey. Providing orders of magnitude increase in sensitivity over Chandra, Lynx will examine the first black holes and their galaxies, map the large-scale structure and galactic halos, and shed new light on the environments of young stars and their planetary systems. In order to meet the Lynx science goals, the telescope consists of a high-angular resolution optical assembly complemented by an instrument suite that may include a High Definition X-ray Imager, X-ray Microcalorimeter and an X-ray Grating Spectrometer. The telescope is integrated onto the spacecraft to form a comprehensive observatory concept. Progress on the formulation of the Lynx telescope and observatory configuration is reported in this paper.

Gaskin, Jessica A.

Design and Testing of a Small Inductive Pulsed Plasma Thruster

The design and testing of a small inductive pulsed plasma thruster (IPPT), shown in Fig. 1 with all the major subsystems required for a thruster of this kind are described. Thrust measurements and imaging of the device operated in rep-rated mode are presented to quantify the performance envelope of the device. The small IPPT described in this paper was designed to serve as a test-bed for the pulsed gas-valves and solid-state switches required for a IPPTs. A modular design approach was used to permit future modifications and upgrades. The thruster consists of the following sub-systems: a) a multi-turn, spiral-wound acceleration coil (27 cm o.d., 10 cm i.d.) driven by a 10 microFarad capacitor and switched with a high-voltage thyristor, b) a fast pulsed gas-valve, and c.) a glow-discharge pre-ionizer (PI) circuit. The acceleration-coil circuit may be operated at voltages up to 4 kV (the thyristor limit is 4.5 kV). The device may be operated at rep-rates up to 30 Hz with the present gas-valve. Thrust measurements and imaging of the device operated in rep-rated mode will be presented. The pre-ionizer consists of a 0.3 microFarad capacitor charged to 4 kV and connected to two annular stainless-steel electrodes bounding the area of the coil-face. The 4 kV potential is held across them and when the gas is puffed in over the coil, the PI circuit is completed, and a plasma is formed. Even at the less than optimal base-pressure in the chamber (approximately 5 × 10(exp −4) torr), the PI held-off the applied voltage, and only discharged upon command. For a capacitor charge of 2 kV the peak coil current is 4.1 kA, and during this pulse a very bright discharge (much brighter than from the PI alone) was observed (see Fig. 2). Interestingly, for discharges at this charge voltage the PI was not required as the current rise rate, dI/dt, of the coil itself was sufficient to ionize the gas.

Martin, Adam K.

Design and Testing of a Small Inductive Pulsed Plasma Thruster

The design and testing of a small inductive pulsed plasma thruster (IPPT) is described. The device was built as a test-bed for the pulsed gas-valves and solid-state switches required for a thruster of this kind, and was designed to be modular to facilitate modification. The thruster in its present configuration consists of a multi-turn, spiral-wound acceleration coil (270 millimeters outer diameter, 100 millimeters inner diameter) driven by a 10 microfarad capacitor and switched with a high-voltage thyristor, a propellant delivery system including a fast pulsed gas-valve, and a glow-discharge pre-ionizer circuit. The acceleration coil circuit may be operated at voltages up to 4 kilovolts (the thyristor limit is 4.5 kilovolts) and the thruster operated at cyclic-rates up to 30 Herz. Initial testing of the thruster, both bench-top and in-vacuum, has been performed. Cyclic operation of the complete device was demonstrated (at 2 Herz), and a number of valuable insights pertaining to the design of these devices have been gained.

Martin, Adam K.