Engineering Papers⌕ Search

Engineering topics

Dilling, J.

Publications and source records attributed to Dilling, J..

At least 37 records · Page 2

Direct Measurement of the Be 7 L / K Capture Ratio in Ta-Based Superconducting Tunnel Junctions

We report a high-statistics measurement of the L / K orbital electron capture ratio in 7 Be embedded in cryogenic Ta. The thin Ta film formed part of a high-resolution superconducting tunnel junction radiation detector that was used to identify the signals from different decay channels. The measured L/K capture ratio of 0.070(7) is significantly larger than the only previous measurement of this quantity and the theoretical predictions that include in-medium effects. This value is a uniquely sensitive probe of the 1s and 2s orbital overlaps with the nucleus and is of relevance to nuclear and atomic physics, as well as Li production in novae and other astrophysical scenarios. Furthermore, this is the first experiment that uses superconducting tunnel junctions for nuclear-recoil detection, opening a new experimental avenue for low-energy precision measurements with rare isotopes.

6 ≤ A ≤ 19↗

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

In this work, liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by γ interactions from 228 Th (2615 keV), 226 Ra (1764 keV), and 60 Co (1332 keV and 1173 keV) calibration sources, over a range of electric fields. The W value that defines the recombination-independent energy scale is measured to be 11.5±0.5 (syst.) ±0.1 (stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV scale, which deviate from extrapolations of lower-energy data. Additionally, a semiempirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double β -decay detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Spectral Shape of the $β$-Decay of 137 Xe to the Ground State of 137 Cs in EXO-200 and Comparison with Theory

Herein we report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden nonunique $β$-decay transition 137 Xe ( 7/2 - ) → 137 Cs ( 7/2 + ) . The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultralow background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal to background ratio of more than 99 to 1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden nonunique $β$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mass measurements of neutron-rich gallium isotopes refine production of nuclei of the first r -process abundance peak in neutron-star merger calculations

We report mass measurements of neutron-rich Ga isotopes 80–85 Ga with TRIUMF's Ion Trap for Atomic and Nuclear science. The measurements determine the masses of 80–83 Ga in good agreement with previous measurements. Here, the masses of 84 Ga and 85 Ga were measured for the first time. Uncertainties between 25 and 48 keV were reached. The new mass values reduce the nuclear uncertainties associated with the production of A ≈ 84 isotopes by the r-process for astrophysical conditions that might be consistent with a binary neutron star (BNS) merger producing a blue kilonova. Our nucleosynthesis simulations confirm that BNS merger may contribute to the first abundance peak under moderate neutron-rich conditions with electron fractions Y e = 0.35–0.38.

59 ≤ A ≤ 89↗

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in liquid xenon

Considering reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE . Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μ m micro-cells conducted with xenon scintillation light ( ~ 175 nm) in liquid xenon. The specular reflectivity at 15 o incidence of three samples of VUV4 SiPMs is found to be 30.4 ± 1.4%, 28.6 ± 1.3%, and 28.0 ± 1.3%, respectively. The PDE at normal incidence differs by ± 8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was further measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.

47 OTHER INSTRUMENTATION↗

Characterization of the Hamamatsu VUV4 MPPCs for nEXO

In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range 163 K = T = 233 K. At an over voltage of 3.1 ± 0.2 V and at T = 163 K we report a number of Correlated Avalanches (CAs) per pulse in the 1µs interval following the trigger pulse of 0.161±0.005. At the same settings the Dark-Noise (DN) rate is 0.137 ± 0.002 Hz/mm2. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at T = 233 K for a mean wavelength of 189 ± 7 nm. At 3.6 ± 0.2 V and 3.5 ± 0.2 V of over voltage we report a PDE of 13.4 ± 2.6 % and 11 ± 2%, corresponding to a saturation PDE of 14.8 ± 2.8 % and 12.2±2.3%, respectively. Both values are well below the 24 % saturation PDE advertised by Hamamatsu. More generally, the second device tested at 3.5 ± 0.2 V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBKLF SiPMs for the final design of the nEXO detector.

Gallina, G↗

Simulation of charge readout with segmented tiles in nEXO

nEXO is a proposed experiment to search for the neutrino-less double beta decay (0νββ) of 136 Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neural network are developed to distinguish simulated 0νββ signals from backgrounds arising from trace levels of natural radioactivity in the detector materials. These simulations indicate that the nEXO TPC with charge-collection tiles shows promising capability to discriminate the 0νββ signal from backgrounds. Furthermore, the estimated half-life sensitivity for 0νββ decay is improved by 20 32)% with the multi-variate (deep neural network) methods considered here, e sensitivity estimated in the nEXO pre-conceptual design report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO

Future ton-scale liquefied noble gas detectors depend on efficient light detection in the vacuum ultraviolet (VUV) range. In the past years, silicon photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large-area avalanche photodiodes. The next-generation double-beta decay experiment, nEXO, with a 5-ton liquid xenon time projection chamber will use SiPMs for detecting the 175-nm xenon scintillation light, in order to achieve an energy resolution of σ/Q ββ =1 %. This paper presents recent measurements of the VUV-HD generation SiPMs from Fondazione Bruno Kessler, Trento, Italy, in two complementary setups. It includes measurements of the photon-detection efficiency (PDE) with gaseous xenon scintillation light in a vacuum setup and dark measurements in a dry nitrogen gas setup. Here, we report improved PDE at 175 nm compared to previous generation devices that would meet the criteria of nEXO. Furthermore, we present the projected nEXO detector light collection and energy resolution that could be achieved by using these SiPMs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of silicon photomultiplier performance in external electric fields

In this paper, we report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149 K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No visible damage to the surface of the devices was caused by the exposure.

Noble liquid detectors (scintillation, ionization,↗

Deep neural networks for energy and position reconstruction in EXO-200

Here, we apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters—total energy and position—directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what was achieved by the conventional approaches developed by EXO-200 over the course of the experiment. Most existing DNN approaches to event reconstruction and classification in particle physics are trained on Monte Carlo simulated events. Such algorithms are inherently limited by the accuracy of the simulation. We describe a unique approach that, in an experiment such as EXO-200, allows to successfully perform certain reconstruction and analysis tasks by training the network on waveforms from experimental data, either reducing or eliminating the reliance on the Monte Carlo.

97 MATHEMATICS AND COMPUTING↗

Mass measurements of neutron-rich indium isotopes toward the N = 82 shell closure

Precise mass measurements of the neutron-rich 125–130 In isotopes have been performed with the TITAN Penning trap mass spectrometer. TITAN's electron beam ion trap was used to charge breed the ions to charge state q = 13+ thus providing the necessary resolving power to measure not only the ground states but also isomeric states at each mass number. Here, the properties of the ground states are investigated through a series of mass differentials, highlighting trends in the indium isotopic chain as compared to its proton-magic neighbor, tin (Z = 50). In addition, the energies of the indium isomers are presented. The (8 - ) level in 128 In is found to be 78 keV lower than previously thought and the (21/2 - ) isomer in 127 In is shown to be lower than the literature value by more than 150 keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of an Ionization Readout Tile for nEXO

Anewdesign for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3 mm wide, on a 10 cm 10 cm fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a 207Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution E=5.5% is observed at 570 keV, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936 V/cm.

Jewell, M J.↗