Engineering PapersSearch

Engineering topics

Dillehay, Michael E.

Publications and source records attributed to Dillehay, Michael E..

Graphite/Epoxy Deicing Heater

Heat applied close to surface protected. One ply of highly electrically- and thermally-conductive brominated-graphite fiber composite laminated between two plies of electrically-insulating composite material, with michel foil making contact with end portions of graphite fibers. Part of foil exposed beyond composite to serve as electrical contact. Graphite/Epoxy composite heater developed to prevent and reverse formation of ice on advanced composite surfaces of aircraft.

Hung, Ching-Cheh

Effects of milling brominated P-100 graphite fibers

Preliminary procedures have been developed for the ball milling of pristine and brominated P-100 graphite fibers. Because of the lubricative properties of graphite, large ball loads (50 percent by volume) are required. Use of 2-propanol as a milling medium enhances the efficiency of the process. The fibers, when allowed to settle from the milling medium, tend to be preferentially aligned with rather few fibers standing up. Milled, brominated P-100 fibers have resistivities that are indistinguishable from their pristine counterparts, apparently because of loss of bromine. This suggests that bromine would not be the intercalate of choice in applications where milled fibers of this type are required. It was found that brominated graphite fibers are stable in a wide variety of organic solvents.

Gaier, James R.

A heater made from graphite composite material for potential deicing application

A surface heater was developed using a graphite fiber-epoxy composite as the heating element. This heater can be thin, highly electrically and thermally conductive, and can conform to an irregular surface. Therefore it may be used in an aircraft's thermal deicing system to quickly and uniformly heat the aircraft surface. One-ply of unidirectional graphite fiber-epoxy composite was laminated between two plies of fiber glass-epoxy composite, with nickel foil contacting the end portions of the composite and partly exposed beyond the composites for electrical contact. The model heater used brominated P-100 fibers from Amoco. The fiber's electrical resistivity, thermal conductivity and density were 50 micro ohms per centimenter, 270 W/m-K and 2.30 gm/cubic cm, respectively. The electricity was found to penetrate through the composite in the transverse direction to make an acceptably low foil-composite contact resistance. When conducting current, the heater temperature increase reached 50 percent of the steady state value within 20 sec. There was no overheating at the ends of the heater provided there was no water corrosion. If the foil-composite bonding failed during storage, liquid water exposure was found to oxidize the foil. Such bonding failure may be avoided if perforated nickel foil is used, so that the composite plies can bond to each other through the perforated holes and therefore lock the foil in place.

Hung, Ching-Cheh