Design and experimental test of a tapered nonlinear transmission line RF source
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Dickens, James.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Here, an experimental study evaluated the feasibility of replacing traditional insulating gases such as SF 6 with C 4 F 7 N (3M TM , Novec 4710) in flux compression generator (FCG) applications. Currently available data indicate that Novec 4710 could offer certain performance benefits over SF 6 . However, the available literature is focused on low frequency (50–60 Hz) and dc at static pressures. To evaluate the performance of Novec 4710 under the pulsed dynamic pressure and temperature conditions found in an FCG, we report a performance comparison between three sets of identical FCGs using air, SF 6 , and Novec 4710 as the insulating gas. The generators used in this study had a single stage, directly seeded design with an armature diameter of 25 mm and a stator diameter of 46 mm. To highlight the performance of the different gases rather than any wire insulation, the stator was constructed with uninsulated wire. Furthermore, the generators were seeded aggressively, making the performance difference between the different gases more apparent. The performance was monitored with a pair of differential Rogowski coils that captured the generators’ di / dt while also using high-speed videography to capture possible gaseous breakdown signatures. The data gathered during this study indicate that Novec 4710 performs at least as well as SF 6 in FCG applications, if not significantly better.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Not provided.
Mitigating electric and magnetic fields induced by lightning strike events is critical for the security and longevity of electrical components. Electromagnetic interference originating from a lightning strike is categorized into the low to medium frequency ranges, commonly referred to as the “magnetic coupling” regime. This low-frequency characteristic brings about the problem of shielding magnetic flux lines. Such shielding can be accomplished with highly conductive materials via the generation of eddy currents or by diverting the flux lines using materials with a large relative permeability. The shielding effectiveness of materials with varying thicknesses and geometry are tested using a pulse forming network having comparable characteristics to a scaled lighting strike. A four-stage Marx generator with a peak current of ~33 kA and a risetime of 1.4 μs is used as the pulse forming network to emulate the scaled electric and magnetic fields. The data collected from these experiments provide information and techniques that can be implemented into the design of a portable, deployable shielding enclosure.
A system to map surface charge densities on dielectric objects – e.g. PTFE, PMMA, and PA6 – is described to study maximum surface charge limits discharge and decay characteristics. Two electromechanical movements are used to achieve these goals: a three-axis robotic arm with an electrostatic probe and a three-axis auxiliary movement fitted with a current viewing resistor and laser displacement sensor. Dielectric objects no larger than a cylinder of eight-inch diameter and twelve inches in height are analyzed to create surface point clouds and generate a set of scan points. The arbitrary object is positioned upon a rotational axis with a laser displacement sensor oriented radially towards the rotational axis of the platform to determine the object’s physical limits.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Surface flashover in vacuum imposes a substantial physical limit on modern, large-scale pulsed power. One of the ramifications is a minimum size requirement for new machines, which in itself becomes a hard barrier to the modernization and improvement of existing infrastructure. Pulsed power topologies require the physical mechanisms of both anode- and cathode-initiated flashover to be considered. Originally, the geometrical implications of field emission at the cathode triple junction (CTJ) motivated the usage of configurations that avoid electrons impinging on the insulating material. This will largely suppress the cathode-initiated flashover, which is best described by the secondary electron avalanche mechanism, gas desorption, and final breakdown in the desorbed gas. It depends on the cascade growth of a conducting plasma along the length of the insulator from the cathode. Mitigating the cathode-initiated flashover typically comes at the cost of a significant field enhancement at the anode triple junction (ATJ). In a typical implementation, the anode field may be three times higher than the cathode field for a given voltage, making the corresponding anode-initiated flashover much more common than otherwise. In the case of pulsed, anode-initiated flashover, experimental evidence suggests that charge is directly extracted from the insulator resulting in the insulator taking on a net positive charge advancing the anode potential. Furthermore, along with accompanying gas desorption from the surface, the potential will then propagate from the anode toward the cathode until the effective length of the gap is sufficiently reduced to support flashover. The underlying physical mechanisms of cathode- and anode-directed flashover are discussed in light of previously gathered experimental data and recent experiments with pulsed, high-gradient, anode-initiated flashover.
While polymer-bonded explosives, PBX, have reduced sensitivity to ignition from mechanical shock or heating compared to conventional explosives, the investigation of the mechanical ignition mechanisms for PBX remains vital to assessing the safety during machining and general handling. Under frictional heating, hot spot generation due to high melting point contaminants in the interface is a suspected source for increased probability of detonation. Here, to investigate such frictional heating, samples of PBX 9501 and PBX 9502 were impacted and skidded against a tangentially moving target and thermally imaged. Temporally resolved temperature and forces were simultaneously measured with and without 300 µm silica grit at the frictional interface. A trend of increasing temperature was observed as the speed and tangential force on the sample increased. Grit particles in the frictional interface were found to act as frictional heat concentration spots owing to the grit's protrusion from the surface and lesser susceptibility to melting compared to the PBX. The coefficient of friction between PBX 9501 and the skidding surface was observed to be largely constant for forces and speeds at the lower end of the test range. In contrast, at high tangential speeds, the coefficient was found to be significantly lower.
Investigation of lightning strikes to conductors ran through long spans of rigid steel conduit was performed. An overdamped-exponential current waveform with controlled peaks and rise rates was used to inject simulated lightning strikes. The impact of the length of wire, length of conduit, grounding location/s, and load type was investigated. Breakdown of 600 V, 12 AWG, THHN insulated wire (3.23 mm OD, 2 mm conductor diameter) was observed for voltages above 45 kV. The presence of resistive loads (between wire and ground) in excess of 20 ohms, or current rise times in excess of 5 kA/μs were found to consistently produce breakdown between wire and conduit. Practical power circuit elements such as outlets and splices were found to breakdown at voltage levels much below the wire insulation failure threshold.
Characterization of surface charge decay for varying materials – PTFE, Acrylic, and metals – of 100 mm diameter, radially symmetric bodies was performed. In a gaseous environment, charged materials will lose their charge depending on gas type, humidity, and other environmental factors. Eventually, the charge will be (1) neutralized by ions or electrons in the surrounding gas (2) distributed by conduction on the material surface or in its volume (3) or neutralized by ions or electrons in the material surface and volume. Metal and polymer samples are charged to a known potential in the tens of kilovolts range, and the decaying voltage is monitored with a non-contact probe until the potential reaches near zero. Humidity has an impact on both groups of materials. As a baseline, in air at 42% relative humidity in an enclosed chamber, a positive charge equivalent to 20 kV potential on a metal sphere of 50 mm radius decays to near zero within 25 minutes. In contrast, the same sphere negatively charged decays slightly faster within 20 minutes. Overall, the humidity has a significant effect on the charge decay time, such that an order of magnitude longer times (hours) are observed at low humidity. Effects of chamber size were also studied, drawing a connection to charge carriers in the air available for decay, with chambers of volume(s): 3.3 105 cm3 and 1.4 106 cm3, respectively.
Undesired accumulation of charge on dielectric materials causing electrostatic discharges can be an issue in pulsed power systems and electrical systems in general. As such, an understanding of surface charge distribution, charge accumulation, and decay is required. An in-house no-contact electrostatic probe designed with a 2 mm resolution was fabricated to measure and map surface charge distribution. Designed as a contactless instrument, the probe consisting of a metal rod and low leakage amplifier circuit probes the electric potential near the surface. A scan of the surface then provides the raw data, a potential distribution. The actual probe response - i.e., the surface charge to voltage transfer function, is accounted for in post-processing. This is accomplished via an Inverse Wien Filter - a technique often applied in image processing - to deconvolve the probe response from the measured data. A commercially available electrostatic probe, the Trek 341B meter with a 3455ET probe, capable of measuring +/- 20 kV was compared to the in- house probe that is designed to cover a wider range from +/- 35 kV. A resolution better than the simple probe resolution is achieved through the distribution’s scanning voltage method and deconvolution. Applying repeated scans, surface charge decay was tracked on various polymer materials to determine the material and environment dependence; materials included were PA6, PTFE, and others. As an example of material dependence, samples charged to 20 kV at 65% humidity experience full charge decay in approximately 45 seconds for PA5 (152 mm dia.), while it took about 100 times longer for PTFE (51 mm dia.) to observe the same decay/redistribution of charge.