Diaz, Aaron A.

Publications and source records attributed to Diaz, Aaron A..

NDE of Novel Materials (CFRP) [Slides]

CFRP composites have not been used for nuclear safety-related applications until recently. In 2019, the ASME Boiler and Pressure Vessel Code Committee approved a new Code Case N-871 for internal repairs of Class 2 and 3 safety-related piping using CFRP for Service Levels A, B, C, and D for a service life of 50 years. The NRC did not review N-871 for inclusion in the Code Case Regulatory Guides. This project focuses on evaluating the capabilities and limitations of Nondestructive Evaluation (NDE) methods for examining the Carbon Fiber Reinforced Polymer (CFRP) repairs in commercial nuclear power plants (NPPs). This Report summarizes the work done on this project until the end of FY24.

36 MATERIALS SCIENCE

Evaluation of Advanced Phased-Array Techniques: Interim Results [Slides]

Report: “Evaluation of Advanced Phased-Array Techniques: Interim Results”, August 2023 ML23216A009, PNNL-34622 Results showed that detection rate drops as microstructures/materials become more complex Standard PA had the highest detection rates overall Detection rates in the CASS-CASS mockups were lowest overall FMC had the most accurate length sizing in the fine-grained WSS mockups. All methods struggled with length sizing in coarse-grained mockups SNR vs method depended on the specimen type SNR was consistently high with standard PA SNR was consistently the lowest with PWI FMC performed best on fine-grained WSS A lack of data received from some Round Robin participants resulted in low statistics for many of the analyses.

42 ENGINEERING

Evaluation of Advanced Phased-Array Techniques: Interim Results [Slides]

Report: “Evaluation of Advanced Phased-Array Techniques: Interim Results”, August 2023 ML23216A009, PNNL-34622 Results showed that detection rate drops as microstructures/materials become more complex Standard PA had the highest detection rates overall Detection rates in the CASS-CASS mockups were lowest overall FMC had the most accurate length sizing in the fine-grained WSS mockups. All methods struggled with length sizing in coarse-grained mockups SNR vs method depended on the specimen type SNR was consistently high with standard PA SNR was consistently the lowest with PWI FMC performed best on fine-grained WSS A lack of data received from some Round Robin participants resulted in low statistics for many of the analyses.

42 ENGINEERING