Engineering PapersSearch

Engineering topics

DiPirro, M.

Publications and source records attributed to DiPirro, M..

The Origins Space Telescope

The Origins Space Telescope will trace the history of our origins from the time dust and heavy elements permanently altered the cosmic landscape to present-day life. How did galaxies evolve from the earliest galactic systems to those found in the universe today? How do habitable planets form? How common are life-bearing worlds? To answer these alluring questions, Origins will operate at mid- and far-infrared wavelengths and offer powerful spectroscopic instruments and sensitivity three orders of magnitude better than that of Herschel, the largest telescope flown in space to date. After a 3 ½ year study, the Origins Science and Technology Definition Team will recommend to the Decadal Survey a concept for Origins with a 5.9-m diameter telescope cryo cooled to 4.5 K and equipped with three scientific instruments. A mid-infrared instrument (MISC-T) will measure the spectra of transiting exoplanets in the 2.8 – 20 μm wavelength range and offer unprecedented sensitivity, enabling definitive biosignature detections. The Far-IR Imager Polarimeter (FIP) will be able to survey thousands of square degrees with broadband imaging at 50 and 250 μm. The Origins Survey Spectrometer (OSS) will cover wavelengths from 25 – 588 μm, make wide-area and deep spectroscopic surveys with spectral resolving power R ~ 300, and pointed observations at R ~ 40,000 and 300,000 with selectable instrument modes. Origins was designed to minimize complexity. The telescope has a Spitzer-like architecture and requires very few deployments after launch. The cryo-thermal system design leverages JWST technology and experience. A combination of current-state-of-the-art cryocoolers and next-generation detector technology will enable Origins’ natural background limited sensitivity.

Leisawitz, D.

The Origins Space Telescope: Mission Concept Overview

The Origins Space Telescope (OST) will trace the history of our origins from the time dust and heavy elements permanently altered the cosmic landscape to present-day life. How did the universe evolve in response to its changing ingredients? How common are life-bearing planets? To accomplish its scientific objectives, OST will operate at mid- and far-infrared wavelengths and offer superlative sensitivity and new spectroscopic capabilities. The OST study team will present a scientifically compelling, executable mission concept to the 2020 Decadal Survey in Astrophysics. To understand the concept solution space, our team studied two alternative mission concepts. We report on the study approach and describe both of these concepts, give the rationale for major design decisions, and briefly describe the mission-enabling technology.

Leisawitz, D.

The Origins Space Telescope Cryo-Thermal Architecture

The Origins Space Telescope (OST) is studied as a future Mid- and Far-Infrared flagship-class observatory. OST will cover the wavelength range from 6 to 600 microns. To reach the sky background for 200-micron wavelengths temperatures of 4 degrees Kelvin or lower are required. To achieve this low temperature active cooling is required, along with passive shielding and passive radiation to deep space. Currently two concepts are being studied: Concept 1 with a 9-meter-diameter primary and a suite of 5 extremely capable instruments providing both imaging and spectroscopy over the entire wavelength range. Concept 2 is a more modest sized telescope with a collecting area equivalent to a 5-meter primary, fewer deployments and 3 or 4 instruments also covering the entire wavelength range for imaging and spectroscopy, although with somewhat reduced spectroscopic resolution, and somewhat slower mapping speed. This paper will describe OST Concept 2's cryogenic thermal architecture and thermal model results.

Space Telescope

Cryogenic Testing of the Thermal Vacuum Chamber and Ground Support Equipment for the James Webb Space Telescope in Chamber A at Johnson Space Center

The James Webb Space Telescope (JWST) is the largest cryogenic instrument telescope to be developed for space flight. The telescope will be passively cooled to 50 K and the instrument package will be at 40 K with the mid-infrared instrument at 6 K. The final cryogenic test of the Optical Telescope Element (OTE) and Integrated Science Instrument Module (ISIM) as an assembly (OTE + ISIM OTIS) will be performed in the largest 15 K chamber in the world, Chamber A at Johnson Space Center. The planned duration of this test will be 100 days in the middle of 2017. Needless to say, this ultimate test of OTIS, the cryogenic portion of JWST will be crucial in verifying the end-to-end performance of JWST. A repeat of this test would not only be expensive, but would delay the launch schedule (currently October 2018). Therefore a series of checkouts and verifications of the chamber and ground support equipment were planned and carried out between 2012 and 2016. This paper will provide a top-level summary of those tests, trades in coming up with the test plan, as well as some details of individual issues that were encountered and resolved in the course of testing.

thermal vacuum chamber

The Far-Infrared Surveyor Mission Study: Paper I, the Genesis

This paper describes the beginning of the Far-Infrared Surveyor mission study for NASA's Astrophysics Decadal 2020. We describe the scope of the study, and the open process approach of the Science and Technology Definition Team. We are currently developing the science cases and provide some preliminary highlights here. We note key areas for technological innovation and improvements necessary to make a Far-Infrared Surveyor mission a reality.

JWST

Cryogenic Autogenous Pressurization Testing for Robotic Refueling Mission 3

A wick-heater system has been selected for use to pressurize the Source Dewar of the Robotic Refueling Mission Phase 3 on-orbit cryogen transfer experiment payload for the International Space Station. Experimental results of autogenous pressurization of liquid argon and liquid nitrogen using a prototype wick-heater system are presented. The wick-heater generates gas to increase the pressure in the tank while maintaining a low bulk fluid temperature. Pressurization experiments were performed in 2013 to characterize the performance of the wick heater. This paper describes the experimental setup, pressurization results, and analytical model correlations.

cryogenics

Measuring the Heat Load on the Flight ASTRO-H Soft Xray Spectrometer Dewar

The Soft Xray Spectrometer (SXS) instrument on-board the ASTRO-H X-ray mission is based on microcalorimeters operating at 50 mK. Low temperature is achieved by use of an adiabatic demagnetization refrigerator (ADR) cyclically operating up to a heat sink at either 1.2 K or 4.5 K. The 1.2 K heat sink is provided by a 40 liter superfluid helium dewar. The parasitic heat to the helium from supports, plumbing, wires, and radiation, and the cyclic heat dumped by the ADR operation determine the liquid helium lifetime. To measure this lifetime we have used various techniques to rapidly achieve thermal equilibrium and then measure the boil-off rate of the helium. We have measured a parasitic heat of 650 microwatts and a cyclic heat of 100 microwatts for a total of 750 microwatts. This closely matches the predicted heat load. Starting with a fill level at launch of more than 33 liters results in a lifetime of greater than 4 years for the liquid helium. The techniques and accuracy for this measurement will be explained in this paper.

cryogenic Equipment

RRM3 Fluid Management Device

The current development progress of the fluid management device (FMD) for the Robotic Resupply Mission 3 (RRM3) cryogen source Dewar is described. RRM3 is an on-orbit cryogenic transfer experiment payload for the International Space Station. The fluid management device is a key component of the source Dewar to ensure the ullage bubble is located away from the outlet during transfer. The FMD also facilitates demonstration of radio frequency mass gauging within the source Dewar. The preliminary design of the RRM3 FMD is a number of concentric cones of Mylar which maximizes the volume of liquid in contact with the FMD in the source Dewar. This paper describes the design of the fluid management device and progress of hardware development

cryogenic fluids

Operation of an ADR Using Helium Exchange Gas as a Substitute for a Failed Heat Switch

The Soft X-ray Spectrometer (SXS) is one of four instruments on the Japanese Astro-H mission, which is currently planned for launch in late 2015. The SXS will perform imaging spectroscopy in the soft X-ray band (0.3-12 keV) using a 6 6 pixel array of microcalorimeters cooled to 50 mK. The detectors are cooled by a 3-stage adiabatic demagnetization refrigerator (ADR) that rejects heat to either a superfluid helium tank (at 1.2 K) or to a 4.5 K Joule-Thomson (JT) cryocooler. Four gas-gap heat switches are used in the assembly to manage heat flow between the ADR stages and the heat sinks. The engineering model (EM) ADR was assembled and performance tested at NASA/GSFC in November 2011, and subsequently installed in the EM dewar at Sumitomo Heavy Industries, Japan. During the first cooldown in July 2012, a failure of the heat switch that linked the two colder stages of the ADR to the helium tank was observed. Operation of the ADR requires some mechanism for thermally linking the salt pills to the heat sink, and then thermally isolating them. With the failed heat switch unable to perform this function, an alternate plan was devised which used carefully controlled amounts of exchange gas in the dewar's guard vacuum to facilitate heat exchange. The process was successfully demonstrated in November 2012, allowing the ADR to cool the detectors to 50 mK for hold times in excess of 10 h. This paper describes the exchange-gas-assisted recycling process, and the strategies used to avoid helium contamination of the detectors at low temperature.

Adiabatic demagnetization

Cryogenic System for the Origins Space Telescope: Cooling a Large Space Telescope to 4K with Today's Technology

The Origins Space Telescope (OST) concept is one of four NASA Science Mission Directorate, Astrophysics Division, observatory concepts being studied for launch in the mid 2030's. OST's wavelength coverage will be from the midinfrared to the sub-millimeter, 6-600 microns. To enable observations at the zodiacal background limit the telescope must be cooled to about 4 K. Combined with the telescope size (currently the primary is 9 m in diameter) this appears to be a daunting task. However, simple calculations and thermal modeling have shown the cooling power required is met with several currently developed cryocoolers. Further, the telescope thermal architecture is greatly simplified, allowing simpler models, more thermal margin, and higher confidence in the final performance values than previous cold observatories. We will describe design principles to simplify modeling and verification. We will argue that the OST architecture and design principles lower its integration and test time and reduce its ultimate cost.

telescopes

Using a Cold Radiometer to Measure Heat Loads and Survey Heat Leaks

We have developed an inexpensive cold radiometer for use in thermal/vacuum chambers to measure heat loads, characterize emissivity and specularity of surfaces and to survey areas to evaluate stray heat loads. We report here the results of two such tests for the James Webb Space Telescope to measure heat loads and effective emissivities of2 major pieces of optical ground support equipment that will be used in upcoming thermal vacuum testing of the Telescope.

DiPirro, M.

The Total Hemispheric Emissivity of Painted Aluminum Honeycomb at Cryogenic Temperatures

NASA uses high-emissivity surfaces on deep-space radiators or thermal radiation absorbers in test chambers. Aluminum honeycomb core material, when coated with a high-emissivity paint, provides a lightweight, mechanically robust, and relatively inexpensive black surface that retains its high emissivity down to low temperatures. At temperatures below about 100 Kelvin, this material performs much better than the paint itself. We measured the total hemispheric emissivity of various painted honeycomb configurations using an adaptation of an innovative technique developed for characterizing thin black coatings. These measurements were performed from room temperature down to 30 Kelvin. We describe the measurement technique and compare the results with predictions from a detailed thermal model of each honeycomb configuration.

Tuttle, J.

Use of Cold Radiometers in Several Thermal/Vacuum Tests

We have developed a low cost low temperature broadband radiometer for use with low temperature tests as a diagnostic tool for measuring stray thermal radiation and remote measurement of material properties. So far these radiometers have been used in two large thermal/vacuum tests for the James Webb Space Telescope (JWST) Project. In the first test the radiometers measured stray radiation in a test of part of the JWST sunshield, and in the second test the radiometers were used to measure the reflectivity and specularity of black Z307 painted aluminum walls on a 25 K cooled shroud. These results will be presented as well as plans for future tests to measure the residual energy through a baffled aperture in the shroud and other stray thermal energy measurements.

DiPirro, M.

Thermal Properties of Double-Aluminized Kapton at Low Temperatures

Double-aluminized kapton (DAK) is commonly used in multi-layer insulation blankets in cryogenic systems. NASA plans to use individual DAK sheets in lightweight deployable shields for satellites carrying instruments. A set of these shields will reflect away thermal radiation from the sun, the earth, and the instrument's warm side and allow the instrument's cold side to radiate its own heat to deep space. In order to optimally design such a shield system, it is important to understand the thermal characteristics of DAK down to low temperatures. We describe experiments which measured the thermal conductivity and electrical resistivity down to 4 Kelvin and the emissivity down to 10 Kelvin.

Tuttle, J.

Ideal Integrating Bolometer

We describe a new "ideal integrator" bolometer as a prototype for a new generation of sensitive, flexible far-IR detectors suitable for use in large arrays. The combination of a non-dissipative sensor coupled with a fast heat switch provides breakthrough capabilities in both sensitivity and operation. The bolometer temperature varies linearly with the integrated infrared power incident on the detector, and may be sampled intermittently without loss of information between samples. The sample speed and consequent dynamic range depend only on the heat switch reset cycle and can be selected in software. Between samples, the device acts as an ideal integrator with noise significantly lower than resistive bolometers. Since there is no loss of information between samples, the device is well-suited for large arrays. A single SQUID readout could process an entire column of detectors, greatly reducing the complexity, power requirements, and cost of readout electronics for large pixel arrays.

Kogut, A.

Space-based Interferometric Telescopes for the Far Infrared

We discuss concepts for deploying direct detection interferometers in space which are optimized for the wavelength range 40 meu to 500 meu. In particular we introduce two missions in NASA's current strategic plan: SPIRIT (SPace InfraRed Interferometric Telescope) and SPECS (Submillimeter Probe of the Evolution of Cosmic Structure).

infrared

A Continuous Adiabatic Demagnetization Refrigerator for Use with Mechanical Coolers

We have begun developing an adiabatic demagnetization refrigerator (ADR) which can produce continuous cooling at temperatures of 50 mK or lower, with high cooling power (goal of 10 PW). The design uses multiple stages to cascade heat from a continuously-cooled stage up to a heat sink. The serial arrangement makes it possible to add stages to extend the operating range to lower temperature, or to raise the heat rejection temperature. Compared to conventional single-shot ADRS, this system achieves higher cooling power per unit mass and is able to reject its heat at a more uniform rate. For operation with a mechanical cryocooler, this latter feature stabilizes the heat sink temperature and allows both the ADR and cryocooler to operate more efficiently. The ADR is being designed to operate with a heat sink as warm as 10-12 K to make it compatible with a wide variety of mechanical coolers as part of a versatile, cryogen-free low temperature cooling system. A two-stage system has been constructed and a proof-of-principle demonstration was conducted at 100 mK. Details of the design and test results, as well as the direction of future work, are discussed.

Shirron, P.