Engineering Papers⌕ Search

Engineering topics

Dhadwal, Harbans S.

Publications and source records attributed to Dhadwal, Harbans S..

System Developed for Real-Time Blade-Flutter Monitoring in the Wind Tunnel

A real-time system has been developed to monitor flutter vibrations in turbomachinery. The system is designed for continuous processing of blade tip timing data at a rate of 10 MB/sec. A USB 2.0 interface provides uninterrupted real-time processing of the data, and the blade-tip arrival times are measured with a 50-MHz oscillator and a 24-bit pipelined architecture counter. The input stage includes a glitch catcher, which reduces the probability of detecting a ghost blade to negligible levels. A graphical user interface provides online interrogation of any blade tip from any light probe sensor. Alternatively, data from all blades and all sensors can be superimposed into a single composite scatter plot displaying the vibration amplitude of each blade.

Kurkov, Anatole P.↗

Optical Measurements of Axial and Tangential Steady-State Blade Deflections Obtained Simultaneously

Case-mounted fiber-optic sensors have been used by aircraft engine manufacturers mainly to monitor blade vibration in fans and compressors. The simplest probe arrangement is a spot probe where, typically, a center fiber transmits laser light, and the outer fibers collect the reflected light from the blade tips and transmit it to a photodetector. Because the spot of incident light is fixed in space, whereas the blade deflects dynamically, the reflected light will originate from slightly different portions of the blade tip under different operating conditions. Unless corrections are developed to compensate for this effect, some error in vibratory tangential amplitude will occur. For monitoring vibrations, this error is usually not critical. However, when steady-state blade deflections are being measured, it is very important to fix the spot on the blade tip at a particular location because the operating speed blade deflections are evaluated against a low-speed reference run. The change in speed usually implies a significant change in the blade orientation and possibly its shape brought about by the aerodynamic and centrifugal loading. It is most convenient to select the blade s leading and trailing edges as the fixed points for which deflections will be evaluated. To capture the blade edges at various speeds, the light probe must be movable. This was achieved by mounting the probe in an eccentric hole in a bushing that fit the fan case in the region that overlapped the path of the blade edge. The probe was actuated to search for a blade edge while all the blades were viewed on an oscilloscope. The blade edge was considered to be captured when a pulse associated with a particular blade was significantly reduced in magnitude but was clearly distinguishable from the background noise level. By tracing the axial position of either blade edge, one could extend the deflection measurement to two dimensions: axial and tangential. These blade deflection measurements were obtained during a wind tunnel test of a fan prototype.

Kurkov, Anatole P.↗

Dual-Laser Probe for Measuring Blade-Tip Clearance Tested

A dual-probe, integrated fiber-optic laser system for measuring blade tip clearance in rotating turbomachinery was developed cooperatively with Integrated Fiber Optic Systems, Inc., and tested at the NASA Lewis Research Center. Because the probes are nearly flush with the casing inner lining, there is minimal flow disturbance. The two probes are closely spaced in a circumferential plane and are slanted at an angle relative to each other so that the time it takes the blade tip to traverse the space between the two beams varies with the tip radius, making it possible to determine the tip clearance at rotor operating conditions. The tip clearance can be obtained for all the blades in a rotor with a single system, provided there are no synchronous vibrations present at a particular operating condition. The two probes for the laser system were installed in two holders. For one, the included angle between the probes was 20 degrees, and for the other, it was 40 degrees. The two configurations were calibrated in a vacuum spin-rig facility that can reproduce realistic blade-tip speeds. A specially designed, nondeflecting rotor was used to calibrate the probes. This rotor consisted of a tapered titanium bar with three teeth on each end, the thickness of which was representative of a typical blade-tip thickness. The bar and measuring teeth were in a horizontal plane in the spin rig, and the axis of rotation was vertical. To set the clearances, we used a remotely controlled optical stage that could be traversed vertically. The 40 probe system also was used to measure the tip clearance during an engine fan prototype test in a wind tunnel. Using the spin-rig calibrations, we estimated the accuracy of the tip-clearance measurement in the test to be 0.005 in. This program is ongoing.

Dhadwal, Harbans S.↗

Simultaneous Optical Measurements of Axial and Tangential Steady-State Blade Deflections

Currently, the majority of fiber-optic blade instrumentation is being designed and manufactured by aircraft-engine companies for their own use. The most commonly employed probe for optical blade deflection measurements is the spot probe. One of its characteristics is that the incident spot on a blade is not fixed relative to the blade, but changes depending on the blade deformation associated with centrifugal and aerodynamic loading. While there are geometrically more complicated optical probe designs in use by different engine companies, this paper offers an alternate solution derived from a probe-mount design feature that allows one to change the probe axial position until the incident spot contacts either a leading or a trailing edge. By tracing the axial position of either blade edge one is essentially extending the deflection measurement to two dimensions, axial and tangential. The blade deflection measurements were obtained during a wind tunnel test of a fan prototype.

Kurkov, Anatole P.↗

Flocculation and aggregation in a microgravity environment (FAME)

An experiment to study flocculation phenomena in the constrained microgravity environment of a space shuttle or space station is described. The small size and light weight experiment easily fits in a Spacelab Glovebox. Using an integrated fiber optic dynamic light scattering (DLS) system we obtain high precision particle size measurements from dispersions of colloidal particles within seconds, needs no onboard optical alignment, no index matching fluid, and offers sample mixing and shear melting capabilities to study aggregation (flocculation and coagulation) phenomena under both quiescent and controlled agitation conditions. The experimental system can easily be adapted for other microgravity experiments requiring the use of DLS. Preliminary results of ground-based study are reported.

Ansari, Rafat R.↗

Microemulsion characterization by the use of a noninvasive backscatter fiber optic probe

This paper demonstrates the utility of a noninvasive backscatter fiber optic probe for dynamic light-scattering characterization of a microemulsion comprising sodium dodecyl sulfate/1-butanol/ brine/heptane. The fiber probe, comprising two optical fibers precisely positioned in a stainless steel body, is a miniaturized and efficient self-beating dynamic light-scattering system. Accuracy of particle size estimation is better than +/- 2 percent.

Ansari, Rafat R.↗

Integrated fiber optic probe for dynamic light scattering

An integrated fiber optic probe, comprising a monomode optical fiber fusion spliced to a short length of a graded-index multimode fiber, is fabricated for use as a coherent receiver in dynamic light scattering. The multimode fiber is cleaved to provide a gradient-index fiber lens with a focal length of 125 microns and an f-number close to unity. An integrated fiber receiver is used to measure the intensity-intensity autocorrelation data from a 0.05 percent by weight concentration of an aqueous suspension of polystyrene latex spheres. Analysis of 100 independent data sets indicates that the particle size can be recovered with an accuracy of +/- 1 percent.

Dhadwal, Harbans S.↗

A Fiber Optic Probe for the Detection of Cataracts

A compact fiber optic probe developed for on-orbit science experiments was used to detect the onset of cataracts, a capability that could eliminate physicians' guesswork and result in new drugs to 'dissolve' or slow down the cataract formation before surgery is necessary. The probe is based upon dynamic light scattering (DLS) principles. It has no moving parts, no apertures, and requires no optical alignment. It is flexible and easy to use. Results are presented for excised but intact human eye lenses. In a clinical setting, the device can be easily incorporated into a slit-lamp apparatus (ophthalmoscope) for complete eye diagnostics. In this set-up, the integrated fiber optic probe, the size of a pencil, delivers a low power cone of laser light into the eye of a patient and guides the light which is backscattered by the protein molecules of the lens through a receiving optical fiber to a photo detector. The non-invasive DLS measurements provide rapid determination of protein crystalline size and its size distribution in the eye lens.

Ansari, Rafat R.↗

Coherent fiber optic sensor for early detection of cataractogenesis in a human eye lens

A lensless backscatter fiber optic probe is used to measure the size distribution of protein molecules inside an excised, but intact, human eye lens. The fiber optic probe, about 5 mm in diameter, can be positioned arbitrarily close to the anterior surface of the eye; it is a trans-receiver, which delivers a Gaussian laser beam into a small region inside the lens and provides a coherent detection of the laser light scattered by the protein molecules in the backward direction. Protein sizes determined from the fast and slow diffusion coefficients show good correlation with the age of the lens and cataractogenesis.

Dhadwal, Harbans S.↗

Method and apparatus for determining the physical properties of materials using dynamic light scattering techniques

A system for determining the physical properties of materials through the use of dynamic light scattering is disclosed. The system includes a probe, a laser source for directing a laser beam into the probe, and a photodetector for converting scattered light detected by the probe into electrical signals. The probe includes at least one optical fiber connected to the laser source and a second optical fiber connected to the photodetector. Each of the fibers may adjoin a gradient index microlens which is capable of providing a collimated laser beam into a scattering medium. The position of the second optical fiber with respect to the optical axis of the probe determines whether homodyne or self-beating detection is provided. Self-beating detection may be provided without a gradient index microlens. This allows a very small probe to be constructed which is insertable through a hypodermic needle or the like into a droplet extending from such a needle. A method of detecting scattered light through the use of a collimated, Gaussian laser beam is also provided. A method for controlling the waist and divergence of the optical field emanating from the free end of an optical fiber is also provided.

Dhadwal, Harbans S.↗

A fiber optic sensor for ophthalmic refractive diagnostics

This paper demonstrates the application of a lensless fiber optic spectrometer (sensor) to study the onset of cataracts. This new miniaturized and rugged fiber optic probe is based upon dynamic light scattering (DLS) principles. It has no moving parts, no apertures, and requires no optical alignment. It is flexible and easy to use. Results are presented for cold-induced cataract in excised bovine eye lenses, and aging effects in excised human eye lenses. The device can be easily incorporated into a slit-lamp apparatus (ophthalmoscope) for complete eye diagnostics.

Ansari, Rafat R.↗

A fiber-optic probe for particle sizing in concentrated suspensions

A fiber-optic probe employing two monomode optical fibers, one for transmitting a Gaussian laser beam to the scattering volume and the second, positioned at some backscatter angle, for receiving the scattered light is described. Performance and suitability of the system for a process control environment is assessed by studying a suspension of polystyrene latex particles over a wide range of sizes and concentrations. The results show that the probe is ideal for a process control environment in industrial and laboratory applications. Particle size is recovered, without any additional corrections for multiple light scattering, in concentrations containing up to 10 percent solids of 39-nm polystyrene latex spheres.

Dhadwal, Harbans S.↗

Multiple fiberoptic probe for several sensing applications

A multiple fiber-optic particle sizing probe which uses a linear array of 11 optical fibers positioned in the focal plane of a graded index microlens is presented. The probe, a compact optical spectrum analyzer, provides simultaneous filtering of the angular spectrum of an extended quasi-monochromatic source. Active and passive configurations provide accurate measurements of the particle size distributions. The multiple fiber-optic probe together with processing electronics is a particle sizing sensor which yields the size distribution within 1-2 min.

Dhadwal, Harbans S.↗

Fiber optic detector probes for laser light scattering

An experimental investigation of the role of fiber optic detector probes in laser light scattering is presented. A quantitative comparison between different detector configurations is accomplished by measuring the time taken for one million photocounts to be accumulated in the extrapolated zeroth delay channel of the net unnormalized intensity time correlation function. A considerable reduction in the accumulation time is achieved by relaxing a rather stringent requirement for the spatial coherence of the optical field.

Dhadwal, Harbans S.↗

Design of fiber optic probes for laser light scattering

A quantitative analysis is presented of the role of optical fibers in laser light scattering. Design of a general fiber optic/microlens probe by means of ray tracing is described. Several different geometries employing an optical fiber of the type used in lightwave communications and a graded index microlens are considered. Experimental results using a nonimaging fiber optic detector probe show that due to geometrical limitations of single mode fibers, a probe using a multimode optical fiber has better performance, for both static and dynamic measurements of the scattered light intensity, compared with a probe using a single mode fiber. Fiber optic detector probes are shown to be more efficient at data collection when compared with conventional approaches to measurements of the scattered laser light. Integration of fiber optic detector probes into a fiber optic spectrometer offers considerable miniaturization of conventional light scattering spectrometers, which can be made arbitrarily small. In addition static and dynamic measurements of scattered light can be made within the scattering cell and consequently very close to the scattering center.

Dhadwal, Harbans S.↗