Engineering topics
Devlin, M.
Publications and source records attributed to Devlin, M..
Bright Laser-Driven Neutron Source Based on the Relativistic Transparency of Solids
Not Available
Status on Establishing the Feasibility of Lead Slowing Down Spectroscopy for Direct Measurement of Plutonium in Used Fuel
Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) from next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration to study the feasibility of Lead Slowing Down Spectroscopy. This technique is an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today’s confirmatory assay methods. This paper will present efforts on the development of time-spectral analysis algorithms, fast neutron detector advances, and validation and testing measurements.
Progress on Establishing the Feasibility of Lead Slowing Down Spectroscopy for Direct Measurement of Plutonium in Used Fuel
Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) of next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT continues to support a multi-institutional collaboration to address the feasibility of Lead Slowing Down Spectroscopy (LSDS) as an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today’s confirmatory assay methods. An LSDS is comprised of a stack of lead (typically 1-6 m3) in which materials to be measured are placed in the lead and a pulse of neutrons is injected. The neutrons in this pulse lose energy due to inelastic and (subsequently) elastic scattering and the average energy of the neutrons decreases as the time increases by a well-defined relationship. In the interrogation energy region (~0.1-1000 eV) the neutrons have little energy spread (~30%) about the average neutron energy. Due to this characteristic, the energy of the (assay) neutrons can then be determined by measuring the time elapsed since the neutron pulse. By measuring the induced fission neutrons emitted from the used fuel, it is possible to determine isotopic-mass content by unfolding the unique structure of isotopic resonances across the interrogation energy region. This paper will present efforts on the development of time-spectral analysis algorithms, fast neutron detector advances, and validation and testing measurements.
Partial γ -ray production cross sections for ( n , x n γ ) reactions in natural argon at 1–30 MeV
Not Available
Lead Slowing Down Spectrometer Status Report
This report documents the progress that has been completed in the first half of FY2012 in the MPACT-funded Lead Slowing Down Spectrometer project. Significant progress has been made on the algorithm development. We have an improve understanding of the experimental responses in LSDS for fuel-related material. The calibration of the ultra-depleted uranium foils was completed, but the results are inconsistent from measurement to measurement. Future work includes developing a conceptual model of an LSDS system to assay plutonium in used fuel, improving agreement between simulations and measurement, design of a thorium fission chamber, and evaluation of additional detector techniques.
High-spin spectrum of 24 Mg studied through multiparticle angular correlations
We describe the investigation of high-spin states in 24 Mg populated with the 12 C( 16 O,α) 24 Mg reaction at 62- and 68-MeV beam energy. The excited states were established through the coincident detection of up to four α and γ particles in complete decay cascades toward a final state of angular momentum zero, the ground state of either 20 Ne or 16 O. We describe a new analysis method for the angular correlations in such events and apply it with the goal to assign spin and parity to α -unbound states in 24 Mg. We establish a number of high-spin, natural-parity states between spins 6 and 12, including the lowest known 10 + and 12 + levels. In conclusion, the energy systematics of positive- and negative-parity high-spin states are compared to the predictions of modern shell-model calculations.
Prompt fission neutron spectra from fission induced by 1 to 8 MeV neutrons on {sup 235}U and {sup 239}Pu using the double time-of-flight technique
Prompt fission neutron spectra from {sup 235}U and {sup 239}Pu were measured for incident neutron energies from 1 to 200 MeV at the Weapons Neutron Research facility (WNR) of the Los Alamos Neutron Science Center, and the experimental data were analyzed with the Los Alamos model for the incident neutron energies of 1-8 MeV. A CEA multiple-foil fission chamber containing deposits of 100 mg {sup 235}U and 90 mg {sup 239}Pu detected fission events. Outgoing neutrons were detected by the Fast Neutron-Induced {gamma}-Ray Observer array of 20 liquid organic scintillators. A double time-of-flight technique was used to deduce the neutron incident energies from the spallation target and the outgoing energies from the fission chamber. These data were used for testing the Los Alamos model, and the total kinetic energy parameters were optimized to obtain a best fit to the data. The prompt fission neutron spectra were also compared with the Evaluated Nuclear Data File (ENDF/B-VII.0). We calculate average energies from both experimental and calculated fission neutron spectra.
Implications of a High Angular Resolution Image of the Sunyaev-Zel'Dovich Effect in RXJ1347-1145
The most X-ray luminous cluster known, RXJ1347-1145 (z = 0.45), has been the object of extensive study across the electromagnetic spectrum. We have imaged the Sunyaev-Zel'dovich effect (SZE) at 90 GHz (lambda = 33 mm) in RXJ1347-1145 at 10" resolution with the 64 pixel MUSTANG bolometer array on the Green Bank Telescope, confirming a previously reported strong, localized enhancement of the SZE 20" to the southeast of the center of X-ray emission. This enhancement of the SZE has been interpreted as shock-heated (>20keV) gas caused by an ongoing major (low mass ratio) merger event. Our data support this interpretation. We also detect a pronounced asymmetry in the projected cluster pressure profile, with the pressure just east of the cluster core approx. 1.6x higher than just to the west. This is the highest resolution image of the SZE made to date.
Detection of Shock-Heated Gas Using the Sz Effect in Rxj 1347-1145
Using the MUSTANG 3.3 mm bolometer array on the GBT we have measured the Sunyaev-Zel'dovich Effect (SZE) in the most x-ray luminous cluster known, RXJ 1 347-1145 (z=0.45) at a resolution of 10" (fwhm). This is the highest resolution image of the SZE to date and confirms previous indications of a localized departure from pressure equilibrium in the form of a small, very hot (>0 keV) parcel of gas, presumably resulting from a merger shock. We discuss the measurements, their interpretation, and future work.
Measurements of the millimeter-wave spectrum of interstellar dust emission
We report measurements of the differential brightness of interstellar dust emission near the Galactic plane and at high Galactic latitudes. The data were obtained as part of a program to measure anisotropy in the cosmic microwave background (CMB). The measurements were made with a 0.5 deg beam size and a 1.3 deg sinusoidal chop, in broad bands (Delta nu/nu approximately 0.3) centered near frequencies of 6, 9, and 12 cm(exp -1). A measurement made toward the Galactic plane, at longitude 1 = 23.7 deg, is compared with the contrast observed in the 100 micrometers IRAS data. Assuming the dust emission has a brightness I(sub nu) proportional to nu(sup n)B(sub nu)(T(sub d)), where B(sub nu) is the Planck function, a best fit yields n = 1.6 +/- 0.4, T(sub d) = 24 +/- 5 K. In a region near the star mu Pegasi (mu PEG l = 91 deg, b = -31 deg), the comparison of our data with the 100 micrometers IRAS data yields n = 1.4 +/- 0.4, and T(sub d) = 18 +/- 3 K. In a second region near the star gamma Ursa Minoris (GUM l = 108 deg, b = 41 deg), an upper limit is placed on contrast in dust emission. This upper limit is consistent with spectrum measured at mu PEG and the IRAS 100 micrometer emission contrast at GUM, which is approximately 8 times lower than mu PEG.
A degree scale anisotropy measurement of the cosmic microwave background near the star Gamma Ursae Minoris
Results from a search for anisotropy in the cosmic microwave background (CMB) are presented from the third flight of the Millimeter-wave Anisotropy experiment. The CMB observation occurred over 1.37 hours and covered a 6.24 sq deg area of the sky where very little foreground emission is expected. Significant correlated structure is observed at 6 and 9/cm. At 12/cm we place an upper limit on the structure. The relative amplitudes at 6, 9, and 12/cm are consistent with a CMB spectrum. The spectrum of the structure is inconsistent with thermal emission from known forms of interstellar dust. Synchrotron and free-free emission would both require unusually flat spectral indices at cm wavelengths in order to account for the amplitude of the observed structure. Although known systematic errors are not expected to contribute significantly to any of the three optical channels, excess sidelobe contamination cannot be definitively ruled out. If all the structure is attributed to CMB anisotropy, a value of the weighted rms of the 6 and 9/cm channels of Delta T/T(CMB) = 4.7 +/- 0.8 x 10 exp -5 (+/- 1 sigma) was measured. If the CMB anisotropy is assumed to have a Gaussian autocorrelation function with a coherence angle of 25 arcmin, then the most probable value is Delta T/T(CMB) = 4.2 +1.7 or -1.1 x 10 exp -5, where the +/- refers to the 95 percent confidence limits.
Measurements of the anisotropy of the cosmic background radiation at 0.5 deg scale near the star Mu Pegasi
Results are presented from the third flight of the MAX experiment, an attitude-controlled balloon-borne millimeter-wave telescope with a 0.5 deg beam, a 1 deg chop, and a three-channel bolometric photometer. Several hours of high-quality data were obtained during a flight on 1991 June 5, including long integrations to search for CBR anisotropy, two separate measurements of dust in the Galactic plane, a brief scan of the Coma Cluster to search for the Sunyaev-Zel'dovich (SZ) effect, and a number of important systematic tests. Data from one of the long CBR integrations, carried out in a region of sky near the star Mu Pegasi, are presented. The primary structure in the data is shown to be emission from Galactic dust via its spectrum and correlation with the IRAS 100/micron map. Several approaches are used to fit this dust component and remove it from the data. An upper limit to CBR anisotropy of deltaT/T less than 2.5 x 10 exp -5 is obtained for a Gaussian autocorrelation function with coherence angle omega(c) = 25'. This limit is significantly higher than the measurement sensitivity of deltaT/T about 1 x 10 exp -5 due to the presence of residual structure in the data after removal of the dust component.
A dc-coupled, high sensitivity bolometric detector system for the Infrared Telescope in Space
We report the performance of an ac bridge readout system that has been developed for use on the Infrared Telescope in Space which is scheduled for launch in 1994. The ac bridge readout provides excellent dc stability enabling observing strategies well-suited to space-borne observations. The ability to modulate the optical signal slowly allows the use of new, highly sensitive, long time-constant bolometers. At 300 mK, the bolometers have an electrical noise equivalent power of 3 x 10 exp -17 W/sq rt Hz. The total noise of the differential signal, including amplifier noise, is less than 8 x 10 exp -17 W/sq rt Hz at frequencies as low as 35 mHz.
Improved low frequency stability of bolometric detectors
An ac bridge readout system has been developed that greatly improves the low-frequency stability of bolometric detectors. The readout can be implemented with a simple circuit appropriate for use in space applications. A matched pair of detectors was used in the readout to achieve system noise within a factor of two of the fundamental noise limit of the detectors at frequencies as low as 10 mHz. The low-frequency stability of the readout system allows slower, more sensitive detectors to be used in many applications, and it facilitates observing strategies that are well suited to spaceborne observations.