Parameters affecting electrostatic cooling
A high voltage electrostatic field is discussed which enhances the rate of normal convective cooling. This cooling rate is a function of starting temperature and voltage applied, and an inverse function of atmospheric pressure or the heat capacity of the surrounding media. It appears that the cooling rate is also a function of current flow; however, additional work is needed to separate other variables from the effect of current flow. The maximum increase in heat loss over the normal convective cooling was approximately 0.167 C/sec (0.3 F/sec) at 316 C (600 F) and 20,000 V. From the data taken it is assumed that the addeded rate of cooling would be increased with higher temperatures and higher voltages. It appears that a high voltage field disrupts the molecular layer of air surrounding a hot body and increases the rate of convective cooling.