Evaluating Performance and Degradation of Bifacial Fields: Approach and Case Study
This presentation cover results of four years of bifacial technology performance and degradation study, presented at the bifiPV 2024.
Engineering topics
Publications and source records attributed to Deline, Chris (ORCID:0000000298678930).
This presentation cover results of four years of bifacial technology performance and degradation study, presented at the bifiPV 2024.
The PV Fleet Performance Data Initiative partners with photovoltaic (PV) fleet owners to collect time-series data of PV production data and publishes aggregated anonymized results of system performance metrics. With an extensive dataset drawn from over 2,200 PV systems across the United States, comprising 8.5 GW and 24,000 separate inverter data channels, this initiative aims to ensure that systemic risks in the US PV fleet are detected. The current work explores system availability, revealing a pronounced dependence on time, especially within the initial 6 months of system performance. Following this start-up period, the average system availability stabilizes. Statistical analyses illustrate a median (P5O) monthly availability of 0.991 and a dependence on system size with a negative trend in availability with increasing system size. This finding indicates that larger systems experience lower availability compared to their smaller counterparts.
The challenge of energy transition is immediate and immense, with current projections targeting 75 TW of photovoltaics (PV) capacity globally by 2050. Alongside the rapid deployment is the "solar-coaster" ride the PV industry experiences with evolving technologies and novel installation methods. In 2016, NREL developed bifacial_radiance, a python open-source modeling tool for bifacial PV. This tool is a wrapper of the raytracing engine Radiance, which you all know better than us at this workshop. Bifacial_radiance integrates the many characteristics of common PV systems to model irradiance on both the front and rear sides of bifacial PV technology - a technology that now represents 75% of utility-scale deployment in the US. Bifacial_radiance has been pivotal for understanding bifacial system performance, shading, and edge effects, and now agrivoltaics research. It has also helped develop simplified models used in PV due diligence tools for optimizing new deployments or evaluating the performance of existing projects. Now, it's the go-to comparison tool for many university, and industry-developed systems modeling tools, and a pivotal tool for further research in photovoltaics. This talk will cover the needs bifacial_radiance addresses as an open-source tool, its development path, and the opportunity for any raytracer to shine light on the solar industry through research and practical application of modeling in regular site installations and novel setups like agrivoltaics and vertical panels at high latitudes (and even the South Pole!).
Bifacial photovoltaic systems oriented vertically facing east-west are an emerging design, targeting production in morning and afternoon hours and providing competitive annual energy yield to traditional south-tilted modules for high latitude locations. The accuracy of existing bifacial PV models when modules are oriented vertically has yet to be examined in detail. Here, we compare four bifacial PV irradiance models in ~150 locations between 15-80 degrees N on the utility-scale, finding higher inter-model deviations for vertical PV systems than south-tilted across all latitudes less than 75 degrees N. We validate model-predicted irradiance with test-site data collected in Golden, Colorado and Fairbanks, Alaska for E-W vertical and south-tilted arrays. View factor models agree with E-W vertical test-site data in Golden with RMSE=15%. Modelling error increases for the Alaskan test-site to RMSE values between 21-30%, driven in part by high albedo measurement uncertainty during snowy months.
In this research, we examine the relationship between aerial IR defect analysis and photovoltaic (PV) performance data for twelve utility- and commercial-scale solar sites in the United States. To do this, we fuse the site diagram geoJSON's, aerial infrared thermography (aIRT) defect analyses, and associated inverter time series, allowing for a direct comparison between site defects and time series data. Defect analyses were provided by Zeitview, under its Solar Insights platform. Following the data fusion process, we look at the relationship between system performance and aIRT defects. We investigate the relationship between degradation and hotspot defects, as well as the relationship between AC power data and offline strings and misaligned modules. In general, system degradation was not affected by long-term or balance-of-system (BoS) defects as they occurred infrequently in the data set. However, for one system, a near statistically significant relationship (p-value=0.057) was found when comparing the degradation of inverter blocks with several multi-hotspot defects to all other inverter blocks without this particular defect. There was strong alignment when comparing short-term recoverable module defects such as stuck trackers and offline strings to time series data. In general, we found that when an inverter block has more than 80% of modules flagged for one of these defects, its AC power time data is flat-lined and the inverter block is not producing.
Challenging climates for Photovoltaics are usually based on climate classification. However, extreme weather events such as high wind, flooding, large hail, extreme snow etc. have become more ubiquitous globally. To study the impact of extraordinary weather events on PV reliability we used two of the largest databases in the USA. First, the National Oceanic and Atmospheric Administration (NOAA) database on extreme weather and secondly, the PV Fleet Data Initiative where we have collected high-resolution PV performance data of more than 8 gigawatts or about 6-7% of all commercial and utility systems in the USA. We analyzed almost 200 systems between 2008-20022 that were immediately impacted by these weather events. The immediate impact (outages) was determined to be about 1% of or a median of approximately 3 days of annual lost production. However, the risk these events pose is exemplified by a long tail where 0.4 % of all systems lost more than 2 weeks annual production. We also found a threshold for high wind (90 km/hr) and hail (25mm), above which we observed significantly higher degradation implying long-term damage to the systems. In addition, we are using satellite imagery to quantify visible damage to PV plants. Finally, we share module, design and installation lessons from some observed case studies to improve extreme weather resilience for PV power systems.
As countries around the world transition towards renewable energy, there is increasing interest in using photovoltaic (PV) technologies to help decarbonize remote northern communities due to their scalability and affordability. However, a major barrier towards large-scale adoption of PV in cold climates is performance uncertainty under extreme environmental conditions including snowfall, freeze-thaw cycles, and high wind loads. Existing literature on PV degradation rates in the North is relatively limited, with published degradation rates varying between -0.2%/year (Sweden) to -1.3%/year (Scotland). At this workshop, we will present preliminary results on the long-term performance of two diverse photovoltaic sites located in Fairbanks, Alaska at 64.8 degrees N: a monofacial Al-BSF double-axis tracking site maintained by the Cold Climate Housing Research Center (CCHRC), and a bifacial PERC/SHJ E-W vertical and south-facing fixed-tilt site maintained by the Alaska Center Energy and Power (ACEP). CCHRC data has been collected over a period of 15 years, while ACEP site data has been collected over 4 years. Using the degradation analysis tool, RdTools, we will present annual system degradation rates, seasonal performance ratio, and identify potential cold climate failure mechanisms for commercially available PV technologies. This analysis will add to existing literature by directly comparing the performance of multiple PV configurations in Alaska.
In a comprehensive study conducted at NREL's 75 kW bifacial single-axis-tracked field, accelerated degradation was observed in four out of five bifacial silicon photovoltaic (PV) module technologies when compared to their monofacial counterparts. Root cause analysis of accelerated bifacial degradation involved various analytical tools and techniques. This included employing RdTools to identify rates of power loss, conducting measurements on fielded and control modules using infrared imaging, electroluminescence (EL) and photoluminescence (PL), quantum efficiency (QE) analysis, IV-curves assessment, as well as utilizing handheld Raman and reflectance measurement targeted at anti-reflective coating. Most cases pointed to carrier lifetime degradation causing Voc loss and simultaneous Isc loss. In some cases, Isc further decreases likely due to optical effects from encapsulant degradation. The outcomes and methodologies employed in this investigation are documented in this publication. This study's significance is further emphasized by placing the findings within the broader context of the performance and degradation of various bifacial systems, as identified in the PV Fleets data.
In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data, and publish aggregated, anonymized results. An assessment of system availability is conducted on 1128 systems which passed our data quality checks, and include cumulative energy meter data. Overall inverter availability is low in the first 6 months of system performance before reaching steady-state by the end of the first year. System-level aggregated data shows a median (P50) system availability of 0.99, and a lower P90 value of 0.95. A dependence on system size is also identified, with better inverter availability results for smaller PV systems. Potential causes of this effect may include the selection of inverter itself: smaller inverters 6kW-250kW showed better average availability than inverters 300kW-5MW. The elimination of string combiner boxes and lower energy impact when one particular inverter goes off-line are potential benefits of a string inverter-based PV system architecture. DNV also analyzed availability data from over 1100 operating systems and found similar trends. DNV's P50 industry guidance on expected availability has been updated to reflect the data and the following observations: utility scale systems have lower availability than DG systems, availability is lower in first year compared to subsequent years, and that actual availability is lower than expected.
The impact of extreme weather events on PV performance was studied by comparing the National Oceanic and Atmospheric Administration database on severe weather with the National Renewable Energy Laboratory's (NREL) PV Fleet database on continuous PV performance. We identified 170 systems that were immediately impacted by weather events. These severe weather events lead to a median loss of only 1 % of annual production. However, flooding and high wind events were found to have an extremely long tail extending to 60 % loss, showing that these discrete events can pose a substantial risk to PV systems. Besides the short-term impact of lost production due to outages, we also found a statistically significant increased performance loss rate (PLR) for high wind events above 90 kilometer/hour, by comparing PLR before and after these events. Similarly, hail events caused higher PLR for hail sizes of and above 25 mm indicating that more stringent hail testing for PV modules is required. In addition, very high snow loads may also cause increased PLRs, but more data are required to better quantify the impact. These findings illustrate the substantial risk extreme weather events pose short-and long-term to fielded PV installations.
This poster discusses AI and ML topics in PV reliability and system performance. In particular, automated metadata extraction and QA for fielded solar installations is covered for the PV Fleets Project. Additionally, statistical learning topics for the PVInsight Project are addressed, as well as development of the PV Validation Hub.
This presentation discusses why we measure irradiance, what makes bifacial irradiance challenging, recommendations for monitoring rear POA irradiance, and a field comparison study.
Large-scale photovoltaic system performance analysis is being conducted within the US Department of Energy's-sponsored PV Fleet Performance Data Initiative. This collaboration with commercial PV system owners collects and evaluates PV field performance data, and provides reports on aggregated results. Drawing on over 2200 sites across the US and over 24,000 separate PV inverters we have collected in excess of 8.3 gigawatts (GW) of performance data, representing 6-7% of the entire US installed PV capacity. A mixture of utility-scale and large commercial systems are represented, averaging 4.1 megawatts (MW) in size and 5 years in age. Initial results show average system degradation rates at -0.75% / year, which is slightly higher than historically reported module-level values of -0.5%/year. We also found that the availability of systems averaged 97.7%, which is lower than the typical 99% uptime assumed by many project economic forecasts. Given these results, we compared monthly performance with expected production values, based on satellite weather data and a simple PVWatts performance model. We found that systems were performing within 10% of monthly expectation over 90% of the time, with a fleet average vs expected monthly value of 0.994. We also evaluated the impact of extreme weather events on system performance, and found a range of short-term and longer-term performance effects ranging from grid outage, system downtime, module damage and accelerated long-term degradation rate.