Engineering Papers⌕ Search

Engineering topics

Dekany, Richard G.

Publications and source records attributed to Dekany, Richard G..

Design and Performance of the PALM-3000 3.5 kHz Upgrade

PALM-3000 (P3K), the second-generation adaptive optics (AO) instrument for the 5.1 meter Hale telescope atPalomar Observatory, was released as a facility class instrument in October 2011 and has since been used on-skyfor over 600 nights as a workhorse science instrument and testbed for coronagraph and detector development.In late 2019 P3K underwent a significant upgrade to its wavefront sensor (WFS) arm and real-time control(RTC) system to reinforce its position as a state-of-the-art AO facility and extend its faint-end capability forhigh-resolution imaging and precision radial velocity follow-up of Kepler and TESS targets. The main featuresof this upgrade include an EM-CCD WFS camera capable of 3.5 kHz framerates, and an advanced Digital SignalProcessor (DSP) based RTC system to replace the aging GPU based system. Similar to the pre-upgrade system,the Shack-Hartmann wavefront sensor supports multiple pupil sampling modes using a motorized lenslet stage.The default sampling mode with 64×64 subapertures has been re-commissioned on-sky in late 2019, witha successful return to science observations in November 2019. In 64×mode the upgraded system is alreadyachieving K-band Strehl ratios up to 85% on-sky and can lock on natural guide stars as faint as mV=16. A16×16 subaperture mode is scheduled for on-sky commissioning in Fall 2020 and will extend the system’s faintlimit even further. Here we present the design and on-sky re-commissioning results of the upgraded system,dubbed P3K-II.

Vasisht, Gautam↗

2900 Square Degree Search for the Optical Counterpart of Short Gamma-Ray Burst GRB 180523B with the Zwicky Transient Facility

There is significant interest in the models for production of short gamma-ray bursts (GRBs). Until now, the number of known short GRBs with multi-wavelength afterglows has been small. While the Fermi GRB Monitor detects many GRBs relative to the Neil Gehrels Swift Observatory, the large localization regions makes the search for counterparts difficult. With the Zwicky Transient Facility (ZTF - part of Palomar Observatory) recently achieving first light, it is now fruitful to use its combination of depth (m (sub AB) approximating 20.6), field of view (approximately 47 square degrees), and survey cadence (every approximately 3 days) to perform Target of Opportunity observations. We demonstrate this capability on GRB 180523B, which was recently announced by the Fermi GRB Monitor as a short GRB. ZTF imaged 2900 square degrees of the localization region, resulting in the coverage of 61.6 percent of the enclosed probability over two nights to a depth of m (sub AB) approximating 20.5. We characterized 14 previously unidentified transients, and none were found to be consistent with a short GRB counterpart. This search with the ZTF shows it is an efficient camera for searching for coarsely localized short GRB and gravitational-wave counterparts, allowing for a sensitive search with minimal interruption to its nominal cadence.

Coughlin, Michael W.↗

Design and Implementation of the PALM-3000 Real-Time Control System

This paper reflects, from a computational perspective, on the experience gathered in designing and implementing realtime control of the PALM-3000 adaptive optics system currently in operation at the Palomar Observatory. We review the algorithms that serve as functional requirements driving the architecture developed, and describe key design issues and solutions that contributed to the system's low compute-latency. Additionally, we describe an implementation of dense matrix-vector-multiplication for wavefront reconstruction that exceeds 95% of the maximum sustained achievable bandwidth on NVIDIA Geforce 8800GTX GPU.

PALM-3000↗

Results from the PALM-3000 High-Order Adaptive Optics System

The first of a new generation of high actuator density AO systems developed for large telescopes, PALM-3000 is optimized for high-contrast exoplanet science but will support operation with natural guide stars as faint as V approx. 18. PALM-3000 began commissioning in June 2011 on the Palomar 200" telescope and has to date over 60 nights of observing. The AO system consists of two Xinetics deformable mirrors, one with 66 by 66 actuators and another with 21 by 21 actuators, a Shack-Hartman WFS with four pupil sampling modes (ranging from 64 to 8 samples across the pupil), and a full vector matrix multiply real-time system capable of running at 2KHz frame rates. We present the details of the completed system, and initial results. Operating at 2 kHz with 8.3cm pupil sampling on-sky, we have achieved a K-band Strehl ratio as high as 84% in approx.1.0 arcsecond visible seeing.

Palomar↗

Development in High-Density Cobra Fiber Positioners for the Subaru Telescope's Prime Focus Spectrometer

The Prime Focus Spectrograph (PFS) is a fiber fed multi-object spectrometer for the Subaru Telescope that will conduct a variety of targeted surveys for studies of dark energy, galaxy evolution, and galactic archaeology. The key to the instrument is a high density array of fiber positioners placed at the prime focus of the Subaru Telescope. The system, nicknamed "Cobra", will be capable of rapidly reconfiguring the array of 2394 optical fibers to the image positions of astronomical targets in the focal plane with high accuracy. The system uses 2394 individual "SCARA robot" mechanisms that are 7.7mm in diameter and use 2 piezo-electric rotary motors to individually position each of the optical fibers within its patrol region. Testing demonstrates that the Cobra positioner can be moved to within 5 micrometers of an astronomical target in 6 move iterations with a success rate of 95%. The Cobra system is a key aspect of PFS that will enable its unprecedented combination of high-multiplex factor and observing efficiency on the Subaru telescope. The requirements, design, and prototyping efforts for the fiber positioner system for the PFS are described here as are the plans for modular construction, assembly, integration, functional testing, and performance validation.

Cobra↗

Real-Time Wavefront Control for the PALM-3000 High Order Adaptive Optics System

We present a cost-effective scalable real-time wavefront control architecture based on off-the-shelf graphics processing units hosted in an ultra-low latency, high-bandwidth interconnect PC cluster environment composed of modules written in the component-oriented language of nesC. The architecture enables full-matrix reconstruction of the wavefront at up to 2 KHz with latency under 250 us for the PALM-3000 adaptive optics systems, a state-of-the-art upgrade on the 5.1 meter Hale Telescope that consists of a 64 x 64 subaperture Shack-Hartmann wavefront sensor and a 3368 active actuator high order deformable mirror in series with a 241 active actuator tweeter DM. The architecture can easily scale up to support much larger AO systems at higher rates and lower latency.

GPU↗

The Palomar Adaptive Optics System

Currently under construction at the Jet Propulsion laboratory, the Palomar Adaptive Optics System (PALAO) is a Cassegrain-mounted system for infrared astronomy incorporating active laser metrology to minimize the effects of mechanical flexure.

Palomar Adaptive Optics System palomar optics PALA↗

Conical Mirrors For Quasi-Retroreflection

Single and multiple-nested conical mirrors assembled and positioned to provide several distinct orders of retroreflection. Design and orientation of "cones" determines positions of, and solid angles subtended by discrete orders of retroreflection. Accommodates larger range of incident angles than corner-cube reflectors. Also provides greater spectral coverage than conventional lens-and mirror retroreflectors. Potential applications include interferometry, metrology, lasers, position and motion sensors, instrument test and calibration, and expanded capability of highway markers and signs.

Dekany, Richard G.↗