Gamma Imaging of Inertial Confinement Fusion Implosions
Explore the source record for details and available documents.
NDSE Static Series V & VI Test Results
The purpose for the Neutron-Diagnosed Subcritical Experiment (NDSE) Static Test Series at the Nevada National Security Site (NNSS) Area 11 is to develop and validate the capability to make precise and accurate measurements of k eff for Special Nuclear Material (SNM) targets with k eff ~ 0.95.1 The series has now completed six sets of measurements using the deuterium-tritium (DT) Dense Plasma Focus (DPF) neutron source, with a Rocky-Flats-Shells Highly Enriched Uranium (RF HEU) target, to measure the gamma die-away to this purpose. The last of these series, Series V and VI, are the subject of this report. Both series were performed on a target comprised of the Object IV HEU + CH 2 configuration, which is identical to Object II but with smaller DPF collimators that limit the incident neutron flux to the HEU radius.
Results of Three Neutron Diagnosed Subcritical Experiments
Neutron diagnosed subcritical experiments (NDSEs) aim to measure the fission chain decay of subcritical test objects initiated by neutrons from an external source. The ultimate goal of future NDSEs is to make such measurements on dynamic subcritical objects as they are imploded. In this work, as a step toward that goal, we made measurements on three static subcritical assemblies containing highly enriched uranium. Specifically, we measured the die-off of both fission gamma rays and neutrons, with nanosecond resolution over several hundred microseconds, relative to the emission time of neutrons from a source in close proximity to the subcritical objects. Additionally, as simulations are expected to play a key role in interpreting future NDSEs, we compared our data to detailed MCNP® calculations. There was good agreement between the data and MCNP over die-off times expected to be most important to future NDSEs, but there were significant differences at both earlier and later times. We attempted to reconcile these differences by several changes to the simulations. In particular, we found that reducing the 235U(n,n’) cross section to 80% of the current ENDF7.1 evaluation resulted in much better agreement.
Improving the time response of a gamma/neutron liquid detector
Explore the source record for details and available documents.
(U) Detector Systems and Data Analysis for NDSE Experiments at the Dense Plasma Focus (DPF)
Explore the source record for details and available documents.
Experimental Physical Sciences Vistas Performance through Science Winter 2017
This issue of Experimental Physical Sciences Vistas focuses on the integrated science that plays a critical role in Los Alamos National Laboratory’s support of the nation’s nuclear deterrent. I hope you will enjoy reading about these accomplishments, opportunities, and challenges.
Development of the dense plasma focus for short-pulse applications
The dense plasma focus (DPF) has long been considered a compact source for pulsed neutrons and has traditionally been optimized for the total neutron yield. Here, we describe the efforts to optimize the DPF for short-pulse applications by introducing a reentrant cathode at the end of the coaxial plasma gun. We reduced the resulting neutron pulse widths by an average of 21±921±9% from the traditional long-drift DPF design. Pulse widths and yields achieved from deuterium-tritium fusion at 2 MA are 61.8±30.761.8±30.7 ns FWHM and 1.84±0.49×10121.84±0.49×10 12 neutrons per shot. Simulations were conducted concurrently to elucidate the DPF operation and confirm the role of the reentrant cathode. Furthermore, a hybrid fluid-kinetic particle-in-cell modeling capability demonstrates correct sheath velocities, plasma instabilities, and fusion yield rates. Consistent with previous findings that the DPF is dominated by beam-target fusion from superthermal ions, we estimate that the thermonuclear contribution is at the 1% level.
Update on NDSE Liquid VI detector design
Presentation summarizes updates to the NDSE Liquid VI detector design to improve performance, including use of LightTools application to optimize time and sensitivity with "egg crate" mirrored light guides.
Liquid VI Detector Time Response
Presentation describes research into use of LightTools, an illumination design program, to optimize time and sensitivity performance in Liquid-VI gamma detectors for neutron-diagnosed experiments.
Improving the time response of a gamma/neutron liquid detector
Presentation describes proposed 5x5 NSDE detector system designed to improve response times in gamma/neutron liquid detector array.
Improving the time response of the NDSE liquid VI detector
Presentation describes proposal to develop a 5x5 grid detector system for neutron-diagnosed experiments using 15" x 15" liquid scintillator units.