Engineering Papers⌕ Search

Engineering topics

De Gersem, Werner

Publications and source records attributed to De Gersem, Werner.

The Outcome for Patients With Pathologic Node-Positive Prostate Cancer Treated With Intensity Modulated Radiation Therapy and Androgen Deprivation Therapy: A Case-Matched Analysis of pN1 and pN0 Patients

Purpose: Improved outcome is reported after surgery or external beam radiation therapy (EBRT) plus androgen deprivation therapy (ADT) for patients with lymph node (LN) positive (N1) prostate cancer (PC). Surgical series have shown that pathologic (p)N1 PC does not behave the same in all patients. The aim of this study was to perform a matched-case analysis to compare the outcome of pN1 and pN0 PC after high-dose EBRT plus ADT. Methods and Materials: Radiation therapy up to 80 Gy was delivered to the prostate with a minimal dose of 45 Gy to the pelvis for pN1 patients. After matching, Kaplan-Meier statistics were used to compare the 5-year biochemical and clinical relapse-free survival (bRFS and cRFS), prostate cancer–specific survival (PCSS), and overall survival (OS). Acute and late rectal and urinary toxicity was evaluated. Results: Sixty-nine pN1 PC patients were matched 1:1 with pN0 PC patients. The median follow-up time was 60 months. The 5-year bRFS and cRFS for pN1 versus pN0 PC patients were 65% ± 7% versus 79% ± 5% (P=.08) and 70% ± 6% versus 83% ± 5% (P=.04) respectively. No significant difference was found in bRFS or cRFS rates between low volume pN1 (≤2 positive LNs) and pN0 patients. The 5-year PCSS and OS were comparable between pN1 and pN0 PC patients: PCSS: 92% ± 4% versus 93% ± 3% (P=.66); OS: 82% ± 5% versus 80% ± 5% (P=.58). Severe toxicity was rare for both groups, although pN1 patients experienced significantly more acute grade 2 rectal toxicity. Conclusion: Primary EBRT plus 2 to 3 years of ADT is a legitimate treatment option for pN1 PC patients, especially those with ≤2 positive LNs, and this with bRFS and cRFS rates comparable to those in pN0 PC patients. For pN1 PC patients with >2 positive LNs, bRFS and cRFS are worse than in pN0 patients, but even in this subgroup, long-term disease control is obtained.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Morphometric Atlas Selection for Automatic Brachial Plexus Segmentation

Purpose: The purpose of this study was to determine the effects of atlas selection based on different morphometric parameters, on the accuracy of automatic brachial plexus (BP) segmentation for radiation therapy planning. The segmentation accuracy was measured by comparing all of the generated automatic segmentations with anatomically validated gold standard atlases developed using cadavers. Methods and Materials: Twelve cadaver computed tomography (CT) atlases (3 males, 9 females; mean age: 73 years) were included in the study. One atlas was selected to serve as a patient, and the other 11 atlases were registered separately onto this “patient” using deformable image registration. This procedure was repeated for every atlas as a patient. Next, the Dice and Jaccard similarity indices and inclusion index were calculated for every registered BP with the original gold standard BP. In parallel, differences in several morphometric parameters that may influence the BP segmentation accuracy were measured for the different atlases. Specific brachial plexus-related CT-visible bony points were used to define the morphometric parameters. Subsequently, correlations between the similarity indices and morphometric parameters were calculated. Results: A clear negative correlation between difference in protraction-retraction distance and the similarity indices was observed (mean Pearson correlation coefficient = −0.546). All of the other investigated Pearson correlation coefficients were weak. Conclusions: Differences in the shoulder protraction-retraction position between the atlas and the patient during planning CT influence the BP autosegmentation accuracy. A greater difference in the protraction-retraction distance between the atlas and the patient reduces the accuracy of the BP automatic segmentation result.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Deformable Image Coregistration in Adaptive Dose Painting by Numbers for Head-and-Neck Cancer

Purpose: To assess the accuracy of contour deformation and feasibility of dose summation applying deformable image coregistration in adaptive dose painting by numbers (DPBN) for head and neck cancer. Methods and Materials: Data of 12 head-and-neck-cancer patients treated within a Phase I trial on adaptive {sup 18}F-FDG positron emission tomography (PET)-guided DPBN were used. Each patient had two DPBN treatment plans: the initial plan was based on a pretreatment PET/CT scan; the second adapted plan was based on a PET/CT scan acquired after 8 fractions. The median prescription dose to the dose-painted volume was 30 Gy for both DPBN plans. To obtain deformed contours and dose distributions, pretreatment CT was deformed to per-treatment CT using deformable image coregistration. Deformed contours of regions of interest (ROI{sub def}) were visually inspected and, if necessary, adjusted (ROI{sub def{sub ad}}) and both compared with manually redrawn ROIs (ROI{sub m}) using Jaccard (JI) and overlap indices (OI). Dose summation was done on the ROI{sub m}, ROI{sub def{sub ad}}, or their unions with the ROI{sub def}. Results: Almost all deformed ROIs were adjusted. The largest adjustment was made in patients with substantially regressing tumors: ROI{sub def} = 11.8 {+-} 10.9 cm{sup 3} vs. ROI{sub def{sub ad}} = 5.9 {+-} 7.8 cm{sup 3} vs. ROI{sub m} = 7.7 {+-} 7.2 cm{sup 3} (p = 0.57). The swallowing structures were the most frequently adjusted ROIs with the lowest indices for the upper esophageal sphincter: JI = 0.3 (ROI{sub def}) and 0.4 (ROI{sub def{sub ad}}); OI = 0.5 (both ROIs). The mandible needed the least adjustment with the highest indices: JI = 0.8 (both ROIs), OI = 0.9 (ROI{sub def}), and 1.0 (ROI{sub def{sub ad}}). Summed doses differed non-significantly. There was a trend of higher doses in the targets and lower doses in the spinal cord when doses were summed on unions. Conclusion: Visual inspection and adjustment were necessary for most ROIs. Fast automatic ROI propagation followed by user-driven adjustment appears to be more efficient than labor-intensive de novo drawing. Dose summation using deformable image coregistration was feasible. Biological uncertainties of dose summation strategies warrant further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving Positioning in High-Dose Radiotherapy for Prostate Cancer: Safety and Visibility of Frequently Used Gold Fiducial Markers

Purpose: The use of gold fiducial markers (GFMs) for prostate positioning in high-dose radiotherapy is gaining interest. The purpose of this study was to compare five GFMs regarding feasibility of ultrasound-based implantation in the prostate and intraprostatic lesion (IPL); toxicity; visibility on transabdominal ultrasound (TU) and cone-beam CT (CBCT); reliability of automatic, soft tissue, and GFM-based CBCT patient positioning by comparing manual and automatic fusion CBCT. Methods and Materials: Twenty-five patients were included. Pain and toxicity were scored after implantation and high-dose radiotherapy. Fisher exact test was used to evaluate the correlation of patients' characteristics and prostatitis. Positioning was evaluated on TU and kilovoltage CBCT images. CBCT fusion was performed automatically (Elekta XVI technology, release 3.5.1 b27, based on grey values) and manually on soft tissue and GFMs. Pearson correlation statistics and Bland-Altman evaluation were used. Five GFMs were compared. Results: Twenty percent of the patients developed prostatitis despite antibiotic prophylaxis. Cigarette smoking was significantly correlated with prostatitis. The visualization of all GFMs on TU was disappointing. Consequently we cannot recommend the use of these GFMs for TU-based prostate positioning. For all GFMs, there was only fair to poor linear correlation between automatic and manual CBCT images, indicating that even when GFMs are used, an operator evaluation is imperative. However, when GFMs were analyzed individually, a moderate to very strong correlation between automatic and manual positioning was found for larger GFMs in all directions. Conclusion: The incidence of prostatitis in our series was high. Further research is imperative to define the ideal preparation protocol preimplantation and to select patients. Automatic fusion is more reliable with larger GFMs at the cost of more scatter. The stability of all GFMs was proven.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IMRT for Sinonasal Tumors Minimizes Severe Late Ocular Toxicity and Preserves Disease Control and Survival

Purpose: To report late ocular (primary endpoint) and other toxicity, disease control, and survival (secondary endpoints) after intensity-modulated radiotherapy (IMRT) for sinonasal tumors. Methods and Materials: Between 1998 and 2009, 130 patients with nonmetastatic sinonasal tumors were treated with IMRT at Ghent University Hospital. Prescription doses were 70 Gy (n = 117) and 60-66 Gy (n = 13) at 2 Gy per fraction over 6-7 weeks. Most patients had adenocarcinoma (n = 82) and squamous cell carcinoma (n = 23). One hundred and one (101) patients were treated postoperatively. Of 17 patients with recurrent tumors, 9 were reirradiated. T-stages were T1-2 (n = 39), T3 (n = 21), T4a (n = 38), and T4b (n = 22). Esthesioneuroblastoma was staged as Kadish A, B, and C in 1, 3, and 6 cases, respectively. Results: Median follow-up was 52, range 15-121 months. There was no radiation-induced blindness in 86 patients available for late toxicity assessment ({>=}6 month follow-up). We observed late Grade 3 tearing in 10 patients, which reduced to Grade 1-2 in 5 patients and Grade 3 visual impairment because of radiation-induced ipsilateral retinopathy and neovascular glaucoma in 1 patient. There was no severe dry eye syndrome. The worst grade of late ocular toxicity was Grade 3 (n = 11), Grade 2 (n = 31), Grade 1 (n = 33), and Grade 0 (n = 11). Brain necrosis and osteoradionecrosis occurred in 6 and 1 patients, respectively. Actuarial 5-year local control and overall survival were 59% and 52%, respectively. On multivariate analysis local control was negatively affected by cribriform plate and brain invasion (p = 0.044 and 0.029, respectively) and absence of surgery (p = 0.009); overall survival was negatively affected by cribriform plate and orbit invasion (p = 0.04 and <0.001, respectively) and absence of surgery (p = 0.001). Conclusions: IMRT for sinonasal tumors allowed delivering high doses to targets at minimized ocular toxicity, while maintaining disease control and survival. Avoidance of severe dry eye syndrome and radiation-induced blindness suggests IMRT as a standard treatment for sinonasal tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alternated Prone and Supine Whole-Breast Irradiation Using IMRT: Setup Precision, Respiratory Movement and Treatment Time

Purpose: The objective of this study was to compare setup precision, respiration-related breast movement and treatment time between prone and supine positions for whole-breast irradiation. Methods and Materials: Ten patients with early-stage breast carcinoma after breast-conserving surgery were treated with prone and supine whole breast-irradiation in a daily alternating schedule. Setup precision was monitored using cone-beam computed tomography (CBCT) imaging. Respiration-related breast movement in the vertical direction was assessed by magnetic sensors. The time needed for patient setup and for the CBCT procedure, the beam time, and the length of the whole treatment slot were also recorded. Results: Random and systematic errors were not significantly different between positions in individual patients for each of the three axes (left-right, longitudinal, and vertical). Respiration-related movement was smaller in prone position, but about 80% of observations showed amplitudes <1 mm in both positions. Treatment slots were longer in prone position (21.2 {+-} 2.5 min) than in supine position (19.4 {+-} 0.8 min; p = 0.044). Conclusion: Comparison of setup precision between prone and supine position in the same patient showed no significant differences in random and systematic errors. Respiratory movement was smaller in prone position. The longer treatment slots in prone position can probably be attributed to the higher repositioning need.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Delineation of the Postprostatectomy Prostate Bed Using Computed Tomography: Interobserver Variability Following the EORTC Delineation Guidelines

Purpose: The present study aims to assess the interobserver agreement of prostate bed delineation after radical prostatectomy using CT alone as proposed by the European Organization for Research and Treatment of Cancer (EORTC) guidelines. Methods and Materials: Six observers delineated the postoperative prostate bed (PB) and the original seminal vesicle position or remnants (SV) of 10 patients according to the EORTC guidelines. Contours were then compared for agreement between observers (the apparent volume overlap and generalized kappa statistics). Standard deviations were also calculated to measure the variability of the position of the outer margins. Results: The mean volume of 100% agreement ({+-}1 standard deviation, SD) was only 5.0 ({+-}3.3) ml for the PB and 0.9 ({+-}1.5) ml for the SV, whereas the mean union of all contours ({+-}1 SD) was 41.1 ({+-}11.8) ml and 25.3 ({+-}13.4) ml, respectively. The mean overall agreement corrected for chance was moderate for both the PB (mean kappa, 0.49; range, 0.35-0.62) and SV (mean kappa, 0.42; range, 0.22-0.59). The overall SD of the outer margins of the PB ranged from 4.6 to 7.0 mm Conclusion: The delineation of the postprostatectomy bed using CT shows only a moderate observer agreement when following the EORTC guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Dose Painting by Numbers for Head-and-Neck Cancer

Purpose: To investigate the feasibility of adaptive intensity-modulated radiation therapy (IMRT) using dose painting by numbers (DPBN) for head-and-neck cancer. Methods and Materials: Each patient's treatment used three separate treatment plans: fractions 1-10 used a DPBN ([{sup 18}-F]fluoro-2-deoxy-D-glucose positron emission tomography [{sup 18}F-FDG-PET]) voxel intensity-based IMRT plan based on a pretreatment {sup 18}F-FDG-PET/computed tomography (CT) scan; fractions 11-20 used a DPBN plan based on a {sup 18}F-FDG-PET/CT scan acquired after the eighth fraction; and fractions 21-32 used a conventional (uniform dose) IMRT plan. In a Phase I trial, two dose prescription levels were tested: a median dose of 80.9 Gy to the high-dose clinical target volume (CTV{sub highdose}) (dose level I) and a median dose of 85.9 Gy to the gross tumor volume (GTV) (dose level II). Between February 2007 and August 2009, 7 patients at dose level I and 14 patients at dose level II were enrolled. Results: All patients finished treatment without a break, and no Grade 4 acute toxicity was observed. Treatment adaptation (i.e., plans based on the second {sup 18}F-FDG-PET/CT scan) reduced the volumes for the GTV (41%, p = 0.01), CTV{sub highdose} (18%, p = 0.01), high-dose planning target volume (14%, p = 0.02), and parotids (9-12%, p < 0.05). Because the GTV was much smaller than the CTV{sub highdose} and target adaptation, further dose escalation at dose level II resulted in less severe toxicity than that observed at dose level I. Conclusion: To our knowledge, this represents the first clinical study that combines adaptive treatments with dose painting by numbers. Treatment as described above is feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Arc Therapy and Intensity-Modulated Radiotherapy for Primary Prostate Radiotherapy With Simultaneous Integrated Boost to Intraprostatic Lesion With 6 and 18 MV: A Planning Comparison Study

Purpose: The aim of the present study was to compare intensity-modulated radiotherapy (IMRT) with volumetric arc therapy (VMAT), in the treatment of prostate cancer with maximal dose escalation to the intraprostatic lesion (IPL), without violating the organ-at-risk constraints. Additionally, the use of 6-MV photons was compared with 18-MV photons for all techniques. Methods and Materials: A total of 12 consecutive prostate cancer patients with an IPL on magnetic resonance imaging were selected for the present study. Plans were made for three IMRT field setups (three, five, and seven fields) and one VMAT field setup (single arc). First, optimal plans were created for every technique using biologic and physical planning aims. Next, an additional escalation to the IPL was planned as high as possible without violating the planning aims of the first step. Results: No interaction between the technique and photon energy (p = .928) occurred. No differences were found between the 6- and 18-MV photon beams, except for a reduction in the number of monitor units needed for 18 MV (p < .05). All techniques, except for three-field IMRT, allowed for dose escalation to a median dose of {>=}93 {+-} 6 Gy (mean {+-} standard deviation) to the IPL. VMAT was superior to IMRT for rectal volumes receiving 20-50 Gy (p < .05). Conclusion: VMAT allowed for dose escalation to the IPL with better sparing of the rectum than static three-, five-, and seven-field IMRT setups. High-energy photons had no advantage over low-energy photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Regional Relapse After Intensity-Modulated Radiotherapy for Head-and-Neck Cancer

Purpose: To evaluate the regional relapse rate in the elective neck using intensity-modulated radiotherapy (IMRT) for head-and-neck cancer. Methods and Materials: We retrospectively analyzed the data from 285 patients treated with IMRT between 2000 and 2008. The median dose prescription to the primary tumor and involved lymph nodes was 69 Gy in 32 fractions. The elective neck was treated simultaneously according to Protocol 1 (multiple dose prescription levels of 56-69 Gy; 2-Gy normalized isoeffective dose, 51-70 Gy; 222 patients) or Protocol 2 (one dose prescription level of 56 Gy; 2-Gy normalized isoeffective dose, 51 Gy; 63 patients). Primary surgery or lymph node dissection was performed before IMRT in 72 (25%) and 157 (55%) patients, respectively. Also, 92 patients (32%) received concomitant chemotherapy. The median follow-up of living patients was 27.4 months (range, 0.3-99). Results: Regional, local, and distant relapse were observed in 16 (5.6%), 35 (12.3%), and 47 (16.5%) patients, respectively. The 2- and 5-year rate of regional relapse was 7% and 10%, respectively, with a trend favoring Protocol 2 (p = 0.06). Seven isolated regional relapses were detected at a median follow-up of 7.3 months in patients treated with Protocol 1 and none in those treated with Protocol 2. Percutaneous gastrostomy was required more frequently in patients who received Protocol 1 (p = 0.079). Conclusion: Isolated regional relapse is rare after IMRT for head-and-neck cancer. Elective neck node doses >51 Gy for a 2-Gy normalized isoeffective dose do not seem to improve regional control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Prostate Bed Motion Using Daily Cone-Beam Computed Tomography During Postprostatectomy Radiotherapy

Purpose: To report on the interfraction total positioning error of the postoperative prostate bed and to quantify its components (bony misalignment [BM]and prostate bed motion [PBM]) using daily kilovoltage cone-beam computed tomography (CBCT). The role of an adaptive radiotherapy schedule (ART) was investigated. Methods and Materials: A total of 547 daily CBCT images from 15 consecutive patients who had been treated with prostate bed radiotherapy were retrospectively analyzed. The positioning error was measured by rigid co-registration of the daily CBCT with pretreatment CT planning scan. The total positioning error was quantified by co-registration of the CBCT with the CT planning scan to match the anterior rectal wall. Automatic bony pelvis co-registration was performed to separate BM and PBM. The ART was determined by the average total positioning error from the first 5 CBCT images. Results: The systematic error for the total positioning error in the left-right, superoinferior, and anteroposterior direction was 2.69, 2.00, and 2.65 mm with a random error of 1.99, 1.49, and 2.25 mm, resulting in a planning target volume margin of 8, 6, and 8 mm, respectively. ART reduced the margin by 54%, 44%, and 40%, respectively. Systematic errors in the left-right, superoinferior, and anteroposterior direction for BM was 2.66, 1.83, and 2.60 mm and for PBM was 0.44, 0.92, and 2.50 mm with a random error of 1.88, 1.24, and 1.77 mm for BM and 0.99, 1.38, and 2.32 mm for PBM, respectively. Conclusion: Without treatment verifications, 6-8-mm planning target volume margins are required because of PBM and BM. The anteroposterior PBM was significant. An ART protocol can reduce these planning target volume margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Results on Setup Precision of Prone-Lateral Patient Positioning for Whole Breast Irradiation

Purpose: The aim of this study was to develop a rapid and reproducible technique for prone positioning and to compare dose-volume indices in prone and supine positions. Methods and Materials: Eighteen patients underwent computed tomography imaging for radiotherapy planning in prone and supine position. Experience was gained in the first eight patients, which lead to modifications of the Horizon prone breast board (Civco Medical Solutions, Orange City, Iowa, USA) and the patient setup technique. A unilateral breast holder (U-BH) was developed (Van de Velde, Schellebelle, Belgium) to retract the contralateral breast away from the treated breast. The technique was then applied to an additional 10 patients. The setup precision was evaluated using daily cone-beam CT. Results: Modifications to the breast board were made to secure a prone-lateral rather then a pure prone position. We evolved from a classical setup using laser marks on the patients' body to a direct breast setup using marks on the breast only. The setup precision of the direct positioning procedure with the modified breast board and the U-BH is comparable to supine setup data in the literature. Dose-volume indices for heart and lung show significantly better results for prone than for supine position, and dose homogeneity within the treated breast did not differ according to the treatment position. Conclusions: The setup precision of our prone-lateral positioning technique is comparable to supine data in literature. Our data show the advantage of prone radiotherapy to spare the lung and heart. Further research is necessary to reduce the duration of prone setup.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypofractionated Intensity-Modulated Arc Therapy for Lymph Node Metastasized Prostate Cancer

Purpose: To determine the planning results and acute toxicity after hypofractionated intensity-modulated arc radiotherapy and androgen deprivation for lymph node metastasized (Stage N1) prostate cancer. Methods and Materials: A total of 31 patients with Stage T1-T4N1M0 prostate cancer were treated with intensity-modulated arc radiotherapy and 3 years of androgen deprivation as primary treatment. The clinical target volume (CTV{sub p}) was the prostate and seminal vesicles. Elective lymph node areas ({sub e}) were delineated and expanded by 2 mm to create the CTV{sub e}. The planning target volumes (PTV{sub p} and PTV{sub e}) were created using a three-dimensional expansion of the CTV{sub p} and CTV{sub e}, respectively, of 7 mm. A median dose of 69.3 Gy and 50 Gy was prescribed to the PTV{sub p} and PTV{sub e} respectively, to be delivered in 25 fractions. Upper and lower gastrointestinal toxicity was scored using the Radiation Therapy Oncology Group toxicity and radiotherapy-induced lower intestinal toxicity scoring system. Genitourinary toxicity was scored using a combined Radiation Therapy Oncology Group, LENT-SOMA (late effects normal tissue-subjective, objective, management, analytic), and Common Toxicity Criteria toxicity scoring system. Results: The median follow-up time was 3 months. The mean prescription dose to the CTV{sub p} and PTV{sub p} was 70.4 Gy and 68.6 Gy, respectively. The minimal dose to the CTV{sub e} and PTV{sub e} was 49.0 Gy and 47.0 Gy, respectively. No acute Grade 2 or greater gastrointestinal toxicity occurred. Fourteen patients developed acute Grade 2 lower gastrointestinal toxicity. Acute Grade 3 and 2 genitourinary toxicity developed in 2 and 14 patients, respectively. Conclusion: The results of our study have shown that hypofractionated intensity-modulated arc radiotherapy as primary therapy for N1 prostate cancer is feasible with low toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗