Computational Investigation of Experimental Interaction Impedance Obtained by Perturbation for Helical Traveling-Wave Tube Structures

Conventional methods used to measure the cold-test interaction impedance of helical slow-wave structures involve perturbing a helical circuit with a cylindrical dielectric rod placed on the central axis of the circuit. It has been shown that the difference in resonant frequency or axial phase shift between the perturbed and unperturbed circuits can be related to the interaction impedance. However, because of the complex configuration of the helical circuit, deriving this relationship involves several approximations. With the advent of accurate three-dimensional (3-D) helical circuit models, these standard approximations can be fully investigated. This paper addresses the most prominent approximations made in the analysis for measured interaction impedance by Lagerstrom and investigates their accuracy using the 3-D simulation code MAFIA. It is shown that a more accurate value of interaction impedance can be obtained by using 3-D computational methods rather than performing costly and time consuming experimental cold-test measurements.

Kory, Carol L.

Accurate Cold-Test Model of Helical TWT Slow-Wave Circuits

Recently, a method has been established to accurately calculate cold-test data for helical slow-wave structures using the three-dimensional (3-D) electromagnetic computer code, MAFIA. Cold-test parameters have been calculated for several helical traveling-wave tube (TWT) slow-wave circuits possessing various support rod configurations, and results are presented here showing excellent agreement with experiment. The helical models include tape thickness, dielectric support shapes and material properties consistent with the actual circuits. The cold-test data from this helical model can be used as input into large-signal helical TWT interaction codes making it possible, for the first time, to design a complete TWT via computer simulation.

Kory, Carol L.

Effect of Helical Slow-Wave Circuit Variations on TWT Cold-Test Characteristics

Recent advances in the state of the art of computer modeling offer the possibility for the first time to evaluate the effect that slow-wave structure parameter variations, such as manufacturing tolerances, have on the cold-test characteristics of helical traveling-wave tubes (TWT's). This will enable manufacturers to determine the cost effectiveness of controlling the dimensions of the component parts of the TWT, which is almost impossible to do experimentally without building a large number of tubes and controlling several parameters simultaneously. The computer code MAFIA is used in this analysis to determine the effect on dispersion and on-axis interaction impedance of several helical slow-wave circuit parameter variations, including thickness and relative dielectric constant of the support rods, tape width, and height of the metallized films deposited on the dielectric rods. Previous computer analyzes required so many approximations that accurate determinations of the effect of many relevant dimensions on tube performance were practically impossible.

Kory, Carol L.

Electron Emission Observations from As-Grown and Vacuum-Coated Chemical Vapor Deposited Diamond

Field emission has been observed from chemical vapor deposited diamond grown on Mo and Si substrates. Emission was observed at fields as low as 20 kV/cm. The samples were tested in the as-grown form, and after coating with thin films of Au, CsI, and Ni. The emission current was typically maximum at the onset of the applied field, but was unstable, and decreased rapidly with time from the as-grown films. Thin Au layers, approximately 15 nm thick, vacuum deposited onto the diamond samples significantly improved the stability of the emission current at values approximately equal to those from uncoated samples at the onset of the applied field. Thin layers of CsI, approximately 5 nm thick, were also observed to improve the stability of the emission current but at values less than those from the uncoated samples at the onset of the applied field. While Au and CsI improved the stability of the emission, Ni was observed to have no effect.

Lamouri, A.

Negative Electron Affinity Effect on the Surface of Chemical Vapor Deposited Diamond Polycrystalline Films

Strong negative electron affinity effects have been observed on the surface of as-grown chemical vapor deposited diamond using Secondary Electron Emission. The test samples were randomly oriented and the surface was terminated with hydrogen. The effect appears as an intensive peak in the low energy part of the spectrum of the electron energy distribution and may be described in the model of effective negative electron affinity.

Krainsky, I. L.

Effects of Surface Treatments on Secondary Electron Emission from CVD Diamond Films

Secondary electron emission (SEE) properties of polycrystalline diamond films grown by chemical vapor deposition (CVD) were measured. The total secondary yield (sigma) from as-grown samples was observed to be as high as 20 at room temperature and 48 while heating at 700 K in vacuum. Electron-beam-activated, alkali-terminated diamond films have shown stable values of sigma as high as 60 when coated with CsI and similarly high values when coated with other alkali halides. Diamond coated with BaF2 had a stable sigma of 6, but no enhancement of the SEE properties was observed with coatings of Ti or Au. Hydrogen was identified to give rise to this effect in as-grown films. However, electron beam exposure led to a reduction in sigma values as low as 2. Exposure to a molecular hydrogen environment restored sigma to its original value after degradation, and enabled stable secondary emission during electron beam exposure. Atomic hydrogen and hydrogen plasma treatments were performed on diamond/Mo samples in an attempt to increase the near-surface hydrogen concentration which might lead to increased stability in the secondary emission. Raman scattering analysis, scanning electron microscopy, and Auger electron spectroscopy (AES) confirmed that hydrogen plasma and atomic hydrogen treatments improved the quality of the CVD diamond significantly. Elastic recoil detection (ERD) showed that heating as-grown diamond targets to 7OO K, which was correlated with an increase in sigma, removed contaminants from the surface but did not drive hydrogen from the diamond bulk. ERD showed that the hydrogen plasma treatment produced an increase in the hydrogen concentration in the near-surface region which did not decrease while heating in vacuum at 700 K, but no improvement in the SEE properties was observed.

Mearini, G. T.

Submillimeter backward-wave oscillators

A novel submillimeter wave backward-wave oscillator (BWO) that can provide tens of mW of power over a voltage tunable frequency range of more than an octave could serve as the local oscillator for a new class of array sensors in the range from 200 to 2000 GHz. The BWO appears to be the best device available for supporting a wide variety of heterodyne detection systems. It is voltage tunable, able to be phase locked, and can provide sufficient power for all envisioned systems including the arrays of detectors needed for fast data recovery in monitoring upper atmospheric conditions.

Stankiewicz, N.

A low-power, high-efficiency Ka-band TWTA

A NASA-sponsored program is described for developing a high-efficiency low-power TWTA operating at 32 GHz and meeting the requirements for the Cassini Mission to study Saturn. The required RF output power of the helix TWT is 10 watts, while the dc power from the spacecraft is limited to about 30 watts. The performance level permits the transmission to earth of all mission data. Several novel technologies are incorporated into the TWT to achieve this efficiency including an advanced dynamic velocity taper characterized by a nonlinear reduction in pitch in the output helix section and a multistage depressed collector employing copper electrodes treated for secondary electron-emission suppression. Preliminary program results are encouraging: RF output power of 10.6 watts is obtained at 14-mA beam current and 5.2-kV helix voltage with overall TWT efficiency exceeding 40 percent.

Curren, A. N.

High efficiency, long life traveling wave tubes for future communications satellites

Electron beam devices, primarily traveling wave tubes (TWTs), have been used as the power amplifiers in almost all space communications and data transmission systems. Based on the technology that is presently available and the expected success of current research efforts, it is reasonable to predict the development of a new class of microwave TWTs with efficiencies in excess of 60 percent and lifetimes of at least ten years. Because of this rapid advance of technology, the TWT is expected to remain the dominant device for power amplifiers in space.

Dayton, J. A., Jr.

Verification of an improved computational design procedure for TWT-dynamic refocuser-MDC systems with secondary electron emission losses

A computational procedure for the design of TWT-refocuser-MDC systems was used to design a short 'dynamic' refocusing system and highly efficient four-stage depressed collector for a 200-W 8-18-GHz TWT. The computations were carried out with advanced multidimensional computer programs which model the electron beam as a series of disks of charge and follow their trajectories from the RF input of the TWT, through the slow-wave structure and refocusing section, to their points of impact in the depressed collector. Secondary emission losses in the MDC were treated semiquantitatively by injecting a representative beam of secondary electrons into the MDC analysis at the point of impact of each primary beam. A comparison of computed and measured TWT and MDC performance showed very good agreement. The electrodes of the MDC were fabricated from a particular form of isotropic graphite that was selected for its low secondary electron yield, thermal expansion characteristics, ease of machinability and vacuum properties. This MDC was tested at CW for more than 1000 h with negligible degradation in TWT and MDC performances.

Ramins, P.

Ultra small electron beam amplifiers

Data on field emission and microfabrication technologies relevant to the development of low-power electron-beam amplifiers and oscillators are discussed. The fabrication of a thin-film field-emission (TFFE) cathode for a 1-W electron-beam amplifier is examined. Some TFFE cathodes have been developed and tested in electron guns. Recent experimental results reveal that a beam can be formed from the field-emission cathode, and the TFFE cathode is applicable for devices operating below 3 kV at currents of less than 20 mA. The use of microfabrication techniques to construct slow-wave circuits is studied, and the use of finned structures as the slow-wave circuit for an electron-beam oscillator or amplifier is proposed.

Dayton, J. A., Jr.

Verification of computer-aided designs of traveling-wave tubes utilizing novel dynamic refocusers and graphite electrodes for the multistage depressed collector

A computational procedure for the design of TWT-refocuser-MDC systems was used to design a short dynamic refocusing system and highly efficient four-stage depressed collector for a 200-W, 8- to 18-GHz, TWT. The computations were carried out with advanced, multidimensional computer programs which model the electron beam as a series of disks of charge and follow their trajectories from the RF input of the TWT, through the slow-wave structure and refocusing section, to their points of impact in the depressed collector. Secondary emission losses in the MDC were treated semi-quantitatively by injecting a representative beam of secondary electrons into the MDC analysis at the point of impact of each primary beam. A comparison of computed and measured TWT and MDC performance showed very good agreement. The electrodes of the MDC were fabricated from a particular form of isotropic graphite that was selected for its low secondary electron yield, ease of machinability, and vacuum properties. This MDC was tested (at CW) for more than 1000 hr with negligible degradation in TWT and MDC performances.

Ramins, P.

Experimental verification of the multistage depressed collector design procedure for a high-perveance, helix-type, traveling-wave tube

The validity of a computational procedure for the design of multistage depressed collectors (MDC's) is demonstrated for a traveling wave tube (TWT) with a perveance of .00000123. The MDC is used with spent-beam refocusing to improve substantially the efficiency of the TWT. Reports on this subject have verified, under a variety of operating conditions, the MDC design procedure for TWT's with lower perveance. The design procedure is based on two computer programs that create a mathematical model of the electric and magnetic fields of the TWT refocuser MDC system and its electron beam. The two principal outputs of the analysis are a description of the radiofrequency (RF) performance of the TWT and the trajectories of representatives groups of charges from the input of the TWT to their points of interception on the MDC electrodes.

Dayton, J. A., Jr.

Experimental verification of a computational procedure for the design of TWT-refocuser-MDC systems

A comparison of analytical and experimental results is presented for a high performance dual-mode helix TWT, equipped with multistage depressed collectors (MDC), and operated over conditions ranging from saturation to the linear regime. The computations are carried out with advanced multidimensional computer programs which model the electron beam as a series of disks or rings of charge and follow their trajectories from the RF input of the TWT, through the slow-wave structure, through the refocusing system, to their points of impact in the depressed collector. TWT performance, collector efficiency, and collector current distribution are computed and compared with measurements. Very good agreement is obtained between computed and measured TWT performance and collector efficiencies. The analytical techniques were subsequently applied to the design of a smaller MDC of nearly equal efficiency.

Dayton, J. A., Jr.

Analytical prediction and experimental verification of performance at various operating conditions of a dual-mode traveling wave tube with multistage depressed collectors

A comparison of analytical and experimental results is presented for a high performance dual-mode traveling wave tube (TWT) operated over a wide range conditions. The computations are carried out with advanced multidimensional computer programs. These programs model the electron beam as a series of disks or rings of charge and follow their trajectories from the rf input of the TWT through the slow-wave structure refocusing system to their points of impacts in the depressed collector. TWT performance, collector efficiency, and collector current distribution are computed and compared with measurements. Very good agreement was obtained between computed and measured TWT performance and collector efficiencies, and the computer design of a highly efficient collector was demonstrated.

Dayton, J. A., Jr.

Three-axis electron-beam test facility

An electron beam test facility, which consists of a precision multidimensional manipulator built into an ultra-high-vacuum bell jar, was designed, fabricated, and operated at Lewis Research Center. The position within the bell jar of a Faraday cup which samples current in the electron beam under test, is controlled by the manipulator. Three orthogonal axes of motion are controlled by stepping motors driven by digital indexers, and the positions are displayed on electronic totalizers. In the transverse directions, the limits of travel are approximately + or - 2.5 cm from the center with a precision of 2.54 micron (0.0001 in.); in the axial direction, approximately 15.0 cm of travel are permitted with an accuracy of 12.7 micron (0.0005 in.). In addition, two manually operated motions are provided, the pitch and yaw of the Faraday cup with respect to the electron beam can be adjusted to within a few degrees. The current is sensed by pulse transformers and the data are processed by a dual channel box car averager with a digital output. The beam tester can be operated manually or it can be programmed for automated operation. In the automated mode, the beam tester is controlled by a microcomputer (installed at the test site) which communicates with a minicomputer at the central computing facility. The data are recorded and later processed by computer to obtain the desired graphical presentations.

Dayton, J. A., Jr.