Engineering PapersSearch

Engineering topics

Davis, W.

Publications and source records attributed to Davis, W..

Development Roadmap for an Adjustable X-Ray Optics Observatory

We are developing adjustable X-ray optics to use on a mission such as SMART-X (see posters 38.02, 38.03 and Presentation 30.03). To satisfy the science problems expected to be posed by the next decadal survey, we anticipate requiring effective area greater than 1 square meter and Chandra-like angular resolution: approximately equal to 0.5 inches. To achieve such precise resolution we are developing adjustable mirror technology for X-ray astronomy application. This uses a thin film of piezoelectric material deposited on the back surface of the mirror to correct for figure distortions, including manufacturing errors and deflections due to gravity and thermal effects. We present here a plan to raise this technology from its current Level 2, to Level 6, by 2018.

Schwartz, Dan

Development of X-Ray Optics for the International X-Ray Observatory (IXO)

The International X-ray Observatory requires mirror assemblies with unprecedented characteristics that cannot be provided by existing optical technologies. In the past several years, the project has supported a vigorous mirror technology development program. This program includes the fabrication of lightweight mirror segments by slumping commercially available thin glass sheets, the support and mounting of these thin mirror segments for accurate metrology, the mounting and attachment of these mirror segments for the purpose of X-ray tests, and development of methods for aligning and integrating these mirror segments into mirror assemblies. This paper describes our efforts and developments in these areas.

Zhang, William W.

Some Considerations for Precision Metrology of Thin X-Ray Mirrors

Determination of the shape of very thin x-ray mirrors employed in spaced-based telescopes continues to be challenging. The mirrors shapes are not readily deduced to the required accuracy because the mount induced distortions are often larger than the uncertainty tolerable for the mission metrology. In addition to static deformations, dynamic and thermal considerations are exacerbated for this class of mirrors. We report on the performance of one temporary mounting scheme for the thin glass mirrors for the Constellation-X mission and prospects for deducing their undistorted shapes.

Lehan, J. P.

In-flight estimation of gyro noise on the Upper Atmosphere Research Satellite (UARS) and Extreme Ultraviolet Explorer (EUVE) missions

This paper characterizes the low-frequency noise response of the Teledyne dry rotor inertial reference unit (DRIRU) gyroscopes on the Upper Atmosphere Research Satellite (UARS) and the Extreme Ultraviolet Explorer (EUVE). The accuracy of spacecraft attitude estimation algorithms that use gyro data for propagating the spacecraft attitude is sensitive to gyro noise. EUVE gyro data were processed to validate a single-axis gyro noise model, which is used onboard various spacecraft. The paper addresses the potential impact of temperature effects on the gyro noise model and the overall impact on attitude determination accuracy. The power spectral density (PSD) of the gyro noise is estimated from UARS in-flight data by Fast Fourier Transform (FFT). The role of actuator dynamics on the PSD function is also discussed.

Lee, M.

The attitude accuracy consequences of on-orbit calibration of the Extreme Ultraviolet Explorer attitude sensors by the Flight Dynamics Facility at Goddard Space Flight Center

The science mission of the Extreme Ultraviolet Explorer (EUVE) requires attitude solutions with uncertainties of 27, 16.7, 16.7 arcseconds (3 sigma) around the roll, pitch, and yaw axes, respectively. The primary input to the attitude determination process is provided by two NASA standard fixed-head star trackers (FHSTs) and a Teledyne dry rotor inertial reference unit (DRIRU) 2. The attitude determination requirements approach the limits attainable with the FHSTs and DRIRU. The Flight Dynamics Facility (FDF) at Goddard Space Flight Center (GSFC) designed and executed calibration procedures that far exceeded the extent and the data volume of any other FDF-supported mission. The techniques and results of this attempt to obtain attitude accuracies at the limit of sensor capability and the results of analysis of the factors that limit the attitude accuracy are the primary subjects of this paper. The success of the calibration effort is judged by the resulting measurement residuals and comparisons between ground- and onboard-determined attitudes. The FHST star position residuals have been reduced to less tha 4 arcsec per axis -- a value that appears to be limited by the sensor capabilities. The FDF ground system uses a batch least-squares estimator to determine attitude. The EUVE onboard computer (OBC) uses an extended Kalman filter. Currently, there are systematic differences between the two attitude solutions that occasionally exceed the mission requirements for 3 sigma attitude uncertainty. Attempts to understand and reduce these differences are continuing.

Hashmall, J.

Postlaunch calibration of spacecraft attitude instruments

The accuracy of both onboard and ground attitude determination can be significantly enhanced by calibrating spacecraft attitude instruments (sensors) after launch. Although attitude sensors are accurately calibrated before launch, the stresses of launch and the space environment inevitably cause changes in sensor parameters. During the mission, these parameters may continue to drift requiring repeated on-orbit calibrations. The goal of attitude sensor calibration is to reduce the systematic errors in the measurement models. There are two stages at which systematic errors may enter. The first occurs in the conversion of sensor output into an observation vector in the sensor frame. The second occurs in the transformation of the vector from the sensor frame to the spacecraft attitude reference frame. This paper presents postlaunch alignment and transfer function calibration of the attitude sensors for the Compton Gamma Ray Observatory (GRO), the Upper Atmosphere Research Satellite (UARS), and the Extreme Ultraviolet Explorer (EUVE).

Davis, W.

Recent Goddard Space Flight Center (GSFC) experience with on-orbit calibration of attitude sensors

The results of on-orbit calibration for several satellites by the flight Dynamics Facility (FDF) at GSFC are reviewed. The examples discussed include attitude calibrations for sensors, including fixed-head star trackers, fine sun sensors, three-axis magnetometers, and inertial reference units taken from recent experience with the Compton Gamma Ray observatory, the Upper Atmosphere Research Satellite, and the Extreme Ultraviolet Explorer calibration. The methods used and the results of calibration are discussed, as are the improvements attained from in-flight calibration.

Davis, W.

Evolution of the Martian atmosphere: The role of the polar caps

Lines of evidence indicate that early in Mars' history, it had a much thicker CO2 atmosphere than it does today. A model was constructed for the evolution of the Martian atmosphere that self consistently calculates the rates at which CO2 is stored in Mars' polar reservoirs. Given some initial abundance, which is assumed to be entirely in the atmosphere, the model calculates the annually averaged temperature of the equatorial region and the polar region, and the planetwide mean. Thus far, results obtained for the case where CO2 condensation in the atmosphere is not a limiting factor. Results fall into two categories: initial inventories above 1 bar and below 1 bar. For inventories above 1 bar, CO2 is partitioned between the atmosphere and regolith with the latter taking up almost 800 mbar of CO2. The rest remains in the atmosphere and is weathered out at a rate proportional to atmospheric pressure. For values less than 1 bar, the evolution scenario is different, polar caps form immediately since there is not enough greenhouse warming to prevent CO2 from going into the regolith and thereby reducing the atmospheric pressure to levels where caps can form. The results do not favor either scenario.

Haberle, R. M.

Properties of large nearly perfect crystals at very low temperatures

A liquid helium cryostat of a size and construction unavailable commercially, was built for use in measuring the Q of several materials at milli-Kelvin temperatures. The design and testing of the cryostat is described as well as the design of the experiment vacuum chamber and adaptor for the dilution refrigerator insert. Theory, design, and testing are also discussed for the magnetic coils built to levitate the materials so as to isolate them and increase the measured Q. A four point suspension with capacitor end plates as the transducer was used to obtain preliminary Q measurements of 6061 aluminum alloy and single crystal silicon. Results are tabulated.

Davis, W.

Solid state crystal physics at very low temperatures

The mechanical dissipation (Q) and resonant frequency of a 15 kg silicon crystal were measured at cryogenic temperatures. In the experiment described, temperature control was incorporated to reduce the time derivative of the temperature. The results of the Q measurements with and without this temperature control are quite different. Measurements of the resonant frequency of the fundamental longitudinal mode of the silicon crystal from 6 to 300 Kelvin are presented and discussed with respect to temperature, df/dT. It is observed that frequency increases as temperature decreases down to about 16 Kelvin, i.e. dt/dT is negative. However, below this temperature the frequency decreases as temperature decreases, i.e. dt/dT is positive. It is suggested that this behavior is related to the coefficient of thermal contraction of silicon, which changes sign at 18 Kelvin. Continuation of these experiments to 20 mK is discussed.

Davis, W.

Solid state crystal physics at very low temperatures

The properties of nearly perfect crystals was studied at cryogenic temperatures. A large Helium 3 and Helium 4 dilution refrigerator has been assembled, and is described. A cryostat suitable for cooling a 35 liter volume to .020 Kelvin was designed and constructed, together with instrumentation to observe the properties of nearly perfect crystals.

Davis, W.

Dewar technology study

The development of a Dewar system for handling liquid helium under weightless conditions is described. Porous plug designs for the prevention of superfluid creep out of the dewar through the vent line were evaluated. For the purpose of designing a neck to provide a transition from the cold cavity to the outside, the loads carried by the neck and equipment supports were studied. Temperature, pressure, and mass flow instrumentation for monitoring Dewar performance were also evaluated. In addition, multilayer blankets consisting of aluminized Mylar separated by Dacron net sheets were designed to insulate the pressure vessel. The dewar system is suggested for use with the star tracking telescope aboard the relativity satellite.

Davis, W.