Engineering Papers⌕ Search

Engineering topics

Daryabeigi, K.

Publications and source records attributed to Daryabeigi, K..

Surface temperature measurements using a thin film thermal array

A thin film device was designed and fabricated to measure surface temperatures. An array of eight integrated thermal sensors are mounted on a 0.002 inch (0.05 mm) Kapton film and multiplexed to obtain an area thermal measurement. The device was tested on a flat plate airfoil and demonstrated a temperature variation of 0.55 C maximum and 0.05 C minimum compared to embedded thermocouples. Future improvements are also discussed.

Dillon-Townes, L. A.↗

Convective heat transfer from circular cylinders located within perforated cylindrical shrouds

The influence of perforated cylindrical shrouds on the convective heat transfer to circular cylinders in transverse flow has been studied experimentally. Geometries studied were similar to those used in industrial platinum resistance thermometers. The influence of Reynolds number, ventilation factor (ratio of the open area to the total surface area of shroud), radius ratio (ratio of shroud's inside radius to bare cylinder's radius), and shroud orientation with respect to flow were studied. The experiments showed that perforated shrouds with ventilation factors in the range 0.1 to 0.4 and radius ratios in the range 1.1 to 2.1 could enhance the convective heat transfer to bare cylinders up to 50%. The maximum enhancement occurred for a radius ratio of 1.4 and ventilation factors between 0.2 and 0.3. It was found that shroud orientation influenced the heat transfer, with maximum heat transfer generally occurring when the shroud's holes were centered on either side of the stagnation line. However, the hole orientation effect is of second order compared to the influence of ventilation factor and radius ratio.

Daryabeigi, K.↗

Thermal sensing of cryogenic wind tunnel model surfaces Evaluation of silicon diodes

Different sensors and installation techniques for surface temperature measurement of cryogenic wind tunnel models were investigated. Silicon diodes were selected for further consideration because of their good inherent accuracy. Their average absolute temperature deviation in comparison tests with standard platinum resistance thermometers was found to be 0.2 K in the range from 125 to 273 K. Subsurface temperature measurement was selected as the installation technique in order to minimize aerodynamic interference. Temperature distortion caused by an embedded silicon diode was studied numerically.

Daryabeigi, K.↗

Measurement of convective heat transfer to solid cylinders inside ventilated shrouds

The influence of ventilated cylindrical shrouds on the convective heat transfer to circular cylinders has been studied experimentally. Geometries studied were similar to those used in commercially available platinum resistance thermometers. Experiments showed that thermal response (convection) was enhanced when the shroud ventilation factor was approximately 20 percent (80 percent solid), and that maximum enhancement occurred when the ventilation holes were located symmetrically on either side of the stagnation lines.

Daryabeigi, K.↗