Engineering Papers⌕ Search

Engineering topics

Darcy, Eric

Publications and source records attributed to Darcy, Eric.

At least 19 records

The battery failure databank: Insights from an open-access database of thermal runaway behaviors of Li-ion cells and a resource for benchmarking risks

The thermal response of Li-ion cells can greatly vary for identical cell designs tested under identical conditions, the distribution of which is costly to fully characterize experimentally. The open-source Battery Failure Databank presented here contains robust, high-quality data from hundreds of abuse tests spanning numerous commercial cell designs and testing conditions. Data was gathered using a fractional thermal runaway calorimeter and contains the fractional breakdown of heat and mass that was ejected, as well as high-speed synchrotron radiography of the internal dynamic response of cells during thermal runaway. The distribution of thermal output, mass ejection, and internal response of commercial cells are compared for different abuse-test conditions, which when normalized on a per amp-hour basis show a strong positive correlation between heat output from cells, the fraction of mass ejected from the cells, their energy- and power-density. Ejected mass was shown to contain 10x more heat per gram than non-ejected mass. The causes of 'outlier' thermal and ejection responses i.e., extreme cases, are elucidated by high-speed radiography which showed how occurrences such as vent clogging can create more hazardous conditions. High-speed radiography also demonstrated how the time-resolved interplay of thermal runaway propagation and mass ejection influences the total heat generated.

25 ENERGY STORAGE↗

The Effect of Cell Geometry and Trigger Method on the Risks Associated with Thermal Runaway of Lithium-Ion Batteries

Consideration of thermal runaway heat output variability is paramount for the development of safe lithium-ion battery assemblies. This study utilizes data gathered from fractional thermal runaway calorimetry (FTRC) experiments to conduct a comparative analysis of thermal runaway heat output for three cell formats (18650, 21700, and 33600) as a function of trigger method (heaters, internal short-circuiting device, and nail penetration). The analysis is based on comparisons for the calculated total energy yield, fractional energy yield, heat rate, and heat flux. This study reveals that nail penetration tends to result in higher thermal runaway heat output for larger cells (21700 & 33600); these experiments also tended to result in higher fractions of the total energy being released through the cell body. The smaller cells (18650) did not appear to have significant variation in heat output as a function of trigger method. This finding suggests that, for this cell type, worst-case scenario heat output could be achievable in assembly level testing regardless of the utilized trigger method. This study also demonstrates successful translation of FTRC results, as recorded in the Battery Failure Databank, into meaningful analysis that breaks down the influence of specific conditions on thermal runaway heat output.

calorimetry↗

Prevention of lithium-ion battery thermal runaway using polymer-substrate current collectors

Isolating electronically conducting material from internal short circuits is a promising way to prevent the onset of thermal runaway within lithium-ion cells. Here, a metal-coated polymer current collector, which is designed to disconnect internal short circuits by withdrawing from the heating region, is tested in 18650 cells. In addition to having lower mass and manufacturing costs, cells with metal-coated polymer current collectors demonstrate a reduced risk of thermal runaway during nail penetration. High-speed synchrotron X-ray radiography of 18650 cells during nail-penetration testing, in tandem with pre- and post-mortem X-ray computed tomography, provides insights into the function of the current collectors. The results are compared with those of 18650 cells with standard commercial aluminum and copper current collectors. Cells with aluminum-coated polymer current collectors demonstrated 100% success in thermal runaway prevention during nail penetration, retaining a cell voltage >4.00 V, while standard cells consistently experienced thermal runaway.

25 ENERGY STORAGE↗

Correlative acoustic time-of-flight spectroscopy and X-ray imaging to investigate gas-induced delamination in lithium-ion pouch cells during thermal runaway

It remains difficult to detect internal mechanical deformation and gas-induced degradation in lithium-ion batteries, especially outside specialized diagnostics laboratories. In this work, we demonstrate that electrochemical acoustic time-of-flight (EA-ToF) spectroscopy can be used as an insightful and field-deployable diagnostic/prognostic technique to sense the onset of failure. A 210 mAh commercial lithium-ion cell undergoing thermal abuse testing is probed with in situ and operando EA-ToF spectroscopy, together with simultaneous fractional thermal runaway calorimetry (FTRC) and synchrotron X-ray imaging. The combination of X-ray imaging and EA-ToF analysis provides new understanding into the through-plane mechanical deformation in lithium-ion batteries through direct visualisation and the acoustic ToF response. Internal structural changes, such as gas-induced delamination, are identified using EA-ToF spectroscopy due to variations in the attenuation and signal peak shifts. This is corroborated using X-ray imaging, demonstrating EA-ToF spectroscopy as a promising technique for detecting onset of battery failure.

25 ENERGY STORAGE↗

Safe, High Power / Voltage Battery Design Challenges

NASA seeks safe, high performing battery module designs that can deliver 3C discharge rates continuously, achieve 160 Wh/kg, and is passively propagation resistant to a single cell thermal runaway event. One solution is presented that uses a patented oscillating heat pipe technology for thermal management. Combined with light weight packaging and a new commercially available gas permeable vent port, all 5 preliminary safety tests results performed to date are showing ample margins.

High power↗

Combining Fractional Calorimetry with Statistical Methods to Characterize Thermal Runaway

Fractional thermal runaway calorimetry (FTRC) techniques were introduced to examine thermal runaway (TR) behavior of lithium-ion (Li-ion) cells. Specifically, FTRC considers the total energy released vs. the fraction of the total energy that is released through the cell casing vs. through the ejecta material. This device has been expanded to universally support FTRC testing of additional cell types including 21700-format, D-Cell format, and large prismatic format Li-ion cells. The TR behavior as influenced by cell format, manufacturer, chemistry, capacity, and in situ safety features are described in this presentation.

Walker, William↗

Metallized Plastic Current Collectors

Metallized plastic current collectors are an innovation patented by the Soteria Battery Innovation Group with the promise of isolating active material involved in an internal short by vaporizing and isolating the short from the rest of the cell electrode jellyroll or stack. Partnering with NREL, UCL, Coulometrics, and Soteria, NASA is leading a research effort into demonstrating the merits and understanding the phenomena of this safety innovation using prototype 18650 cylindrical cells vs control cells with standard metal foil current collectors. Cells with and without the plastic collector, with and without the on-demand internal short circuit device, and with polymer or cellulose separators were made. Safety evaluations were done with driving cells into thermal runaway (TR) with thermal and nail penetration triggers while inside our TR calorimeter and with ultra high speed X-ray videography provided at Synchrotrons. Preliminary results suggests that the thermally unstable plastic current collector innovation has great promise for preventing TR or reducing the severity of the TR output.

Li-ion cell↗

Safe, High Power/Voltage Battery Module Design Challenges

NASA seeks to demonstrate a path for achieving safe, high power, and high performing Li-ion battery designs for the purpose of establishing design guidelines for our aeronautic and spacecraft applications. Safe means passively resistant to thermal runaway propagation of any single cell catastrophic thermal runaway. High power means capable of 3C continuous discharge without overheating. High performing means achieving > 160 Wh/kg, 200 Wh/L. The biggest challenge has been balancing a high flux light weight path for cell heat dissipation during the high rate discharge that minimizes thermal gradients between cells and also protects adjacent cells from the heat load of thermal runaway cell. Our solution includes an oscillating heat pipe spine that contacts every 18650 cell in the pack and careful cell design selection to maximize the range of initial temperatures conditions where the battery can safely complete the 3C discharge.

Thermal runaway↗

Coupling Fractional Thermal Runaway Calorimetry (FTRC) Results with Statistical Analysis Methods

Important factors to consider when optimizing Lithium-ion (Li-ion) battery thermal management systems, from a battery safety perspective, include the total energy released during a single cell thermal runaway (TR) event and the fraction of the total energy that is released through the cell casing versus through the ejecta material. A fractional thermal runaway calorimeter (FTRC) was used to examine the TR behavior of the following 18650-format Li-ion cells: (1) Molicel 18650-J, (2) LG 18650-HG2, (3) Samsung 18650-30Q, (4) 3.35 Ah LG 18650 test cell, (5) Sony 18650-VC7, and (6) LG 18650-MJ1. These cells were intentionally selected to represent a variety of manufacturers, chemistries, capacities, and safety features. Because of the large number of random and non-random variables associated with the FTRC results, a linear regression model, developed using engineering statistical methods, was utilized to provide final interpretation of the TR behavior for each cell type and design variable combination.

Walker, William↗

Combining Fractional Calorimetry with Statistical Methods to Characterize Thermal Runaway

Thermal management systems designed to handle the impacts of thermal runaway (TR) are key to safe operation of lithium-ion (Li-ion) batteries. Critical factors for optimizing these systems include the total energy released and the fraction of the total energy that is released through the cell casing versus through the ejecta material. A unique calorimeter, designed to characterize said factors, was utilized to examine the TR behavior of a variety of 18650-format Li-ion cells. Statistical methods were implemented to interpret the data.

Walker, William↗