Engineering Papers⌕ Search

Engineering topics

Danon, Yaron

Publications and source records attributed to Danon, Yaron.

At least 73 records · Page 4

New Approach in Fissile Assay Using LSDS - 17076

A quantitative assay of isotopic fissile materials (U{sup 235}, Pu{sup 239}, Pu{sup 241}) was conducted at the Korea Atomic Energy Research Institute (KAERI), using a lead slowing down spectrometer (LSDS). Using a uranium rod and plutonium, the actual measurement of induced fission neutrons was performed in the RPI (Rensselaer Polytechnic Institute) LSDS facility. In the simulation, a content of U{sup 235}, Pu{sup 239}, and Pu{sup 241} was changed. The detected signal has a direct relationship with the mass of the existing fissile isotopes. The mathematical model for fissile assay was applied to the measured and simulated detection data. The assay results show that the isotopic content was consistent with 2 to 3% uncertainty for Pu{sup 239}. The simulation indicated that the assay result was affected by the self-shielding correction. Usually, in highly enriched plutonium, the correction plays an important role and good understanding of it is required in order to increase assay accuracy. The combination of LSDS technique measurement and simulation is a very powerful and direct way to analyze the isotopic fissile content. The information provided by such analysis is applicable to nuclear fuel cycle development and spent fuel management for safety and economics. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improvements to Thermal Neutron Scattering Law of CH{sub 2}

MCNP, as a widely accepted simulation tool, depends heavily on evaluated nuclear data found in current ENDF libraries. Modeling CH{sub 2} (polyethylene), as one of the prominent moderators, is of high importance for many applications such as spent fuel storage or shipping systems. Current thermal scattering S (α, β) evaluations are based on theoretical calculations of the phonon spectrum that are usually adjusted to match the energy dependent total scattering cross section. Double differential scattering data is not always available and thus rarely used in the evaluation. In this work double differential scattering measurements were used to obtain a phonon spectrum that can be used to generate a thermal scattering evaluation. This procedure resulted in better agreement with the experimental total cross section of CH{sub 2} and better agreement with double differential scattering experiments. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron-detecting apparatuses and methods of fabrication

Neutron-detecting structures and methods of fabrication are provided which include: a substrate with a plurality of cavities extending into the substrate from a surface; a p-n junction within the substrate and extending, at least in part, in spaced opposing relation to inner cavity walls of the substrate defining the plurality of cavities; and a neutron-responsive material disposed within the plurality of cavities. The neutron-responsive material is responsive to neutrons absorbed for releasing ionization radiation products, and the p-n junction within the substrate spaced in opposing relation to and extending, at least in part, along the inner cavity walls of the substrate reduces leakage current of the neutron-detecting structure.

36 MATERIALS SCIENCE↗

Radiation Stability of Spark‐Plasma‐Sintered Lead Vanadate Iodoapatite

Spark‐plasma‐sintered lead vanadate iodoapatite Pb 9.85 (VO 4 ) 6 I 1.7 , a promising nuclear waste form for the immobilization of I‐129, was irradiated with energetic ions, electrons, and gamma rays, to investigate its radiation stability. In situ TEM observation of the 1 MeV Kr 2+ irradiation shows that lead vanadate iodoapatite generally exhibits higher tolerance against ion irradiation‐induced amorphization than lead vanadate fluorapatite, and the spark plasma sintering can further enhance its radiation stability attributed to the enhanced crystallinity, reduced defect concentration, and denser microstructure. The critical amorphization dose and critical temperature for the SPS‐densified iodoapatite at 700°C are determined to be 0.25 dpa at room temperature and 230°C, respectively. No significant phase transformation or microstructural damage occurred under energetic electron and gamma irradiations. Raman spectra of gamma‐ray‐irradiated iodoapatite indicate improved V–O bond order at 500 kGy dose. Generally, the spark‐plasma‐sintered iodoapatite exhibits excellent radiation stability for nuclear waste form applications. The significantly enhanced radiation stability of the SPS‐densified iodoapatite suggests that SPS holds great promise for fabricating iodoapatite waste form with minimum iodine loss and optimized radiation tolerance for effective management of highly volatile I‐129.

Lu, Fengyuan↗

Lead Slowing Down Spectrometry Analysis of Data from Measurements on Nuclear Fuel

Improved non-destructive assay of isotopic masses in used nuclear fuel would be valuable for nuclear safeguards operations associated with the transport, storage and reprocessing of used nuclear fuel. Our collaboration is examining the feasibility of using lead slowing down spectrometry techniques to assay the isotopic fissile masses in used nuclear fuel assemblies. We present the application of our analysis algorithms on measurements conducted with a lead spectrometer. The measurements involved a single fresh fuel pin and discrete 239Pu and 235U samples. We are able to describe the isotopic fissile masses with root mean square errors over seven different configurations to 6.35% for 239Pu and 2.7% for 235U over seven different configurations. Funding Source(s):

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lead Slowing Down Spectrometer FY2013 Annual Report

Executive Summary The Lead Slowing Down Spectrometry (LSDS) project, funded by the Materials Protection And Control Technology campaign, has been evaluating the feasibility of using LSDS techniques to assay fissile isotopes in used nuclear fuel assemblies. The approach has the potential to provide considerable improvement in the assay of fissile isotopic masses in fuel assemblies compared to other non-destructive techniques in a direct and independent manner.

Warren, Glen A.↗

Non-destructive Assay Measurements Using the RPI Lead Slowing Down Spectrometer

The use of a Lead Slowing-Down Spectrometer (LSDS) is consid- ered as a possible option for non-destructive assay of fissile material of used nuclear fuel. The primary objective is to quantify the 239Pu and 235U fissile content via a direct measurement, distinguishing them through their characteristic fission spectra in the LSDS. In this pa- per, we present several assay measurements performed at the Rensse- laer Polytechnic Institute (RPI) to demonstrate the feasibility of such a method and to provide benchmark experiments for Monte Carlo cal- culations of the assay system. A fresh UOX fuel rod from the RPI Criticality Research Facility, a 239PuBe source and several highly en- riched 235U discs were assayed in the LSDS. The characteristic fission spectra were measured with 238U and 232Th threshold fission cham- bers, which are only sensitive to fission neutron with energy above the threshold. Despite the constant neutron and gamma background from the PuBe source and the intense interrogation neutron flux, the LSDS system was able to measure the characteristic 235U and 239Pu responses. All measurements were compared to Monte Carlo simula- tions. It was shown that the available simulation tools and models are well suited to simulate the assay, and that it is possible to calculate the absolute count rate in all investigated cases.

Lead Slowing Down Spectrometer↗

Development of A Self Biased High Efficiency Solid-State Neutron Detector for MPACT Applications

Neutron detection is an important aspect of materials protection, accounting, and control for transmutation (MPACT). Currently He-3 filled thermal neutron detectors are utilized in many applications; these detectors require high-voltage bias for operation, which complicates the system when multiple detectors are used. In addition, due to recent increase in homeland security activity and the nuclear renaissance, there is a shortage of He-3, and these detectors become more expensive. Instead, cheap solid-state detectors that can be mass produced like any other computer chips will be developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Update on Establishing the Feasibility of Lead Slowing Down Spectroscopy for Direct Measurement of Plutonium in Used Fuel

Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) of next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration to address the feasibility of Lead Slowing Down Spectroscopy (LSDS) as an active, nondestructive assay method. LSDS has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than today’s confirmatory assay methods, for which typical uncertainties are approximately 10%. LSDS techniques are sensitive to the fission resonances in the energy range of ~0.1-1000 eV, enabling their use to determine the mass content of the fissile isotopes in used fuel. This paper will present an update with regard to applying LSDS for used fuel assay and the development of algorithms to extract fissile isotopic masses from the used fuel.

Lead Slowing Down Spectroscopy, Used Fuel, Spent F↗

High detection efficiency micro-structured solid-state neutron detector with extremely low leakage current fabricated with continuous p-n junction

We report the continuous p-n junction formation in honeycomb structured Si diode by in situ boron deposition and diffusion process using low pressure chemical vapor deposition for solid-state thermal neutron detection applications. Optimized diffusion temperature of 800 Degree-Sign C was obtained by current density-voltage characteristics for fabricated p{sup +}-n diodes. A very low leakage current density of {approx}2 Multiplication-Sign 10{sup -8} A/cm{sup 2} at -1 V was measured for enriched boron filled honeycomb structured neutron detector with a continuous p{sup +}-n junction. The neutron detection efficiency for a Maxwellian spectrum incident on the face of the detector was measured under zero bias voltage to be {approx}26%. These results are very encouraging for fabrication of large area solid-state neutron detector that could be a viable alternative to {sup 3}He tube based technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lead Slowing Down Spectrometer Research Plans

The MPACT-funded Lead Slowing Down Spectrometry (LSDS) project has been evaluating the feasibility of using LSDS techniques to assay fissile isotopes in used nuclear fuel assemblies. The approach has the potential to provide considerable improvement in the assay of fissile isotopic masses in fuel assemblies compared to other non-destructive techniques in a direct and independent manner. The LSDS collaborations suggests that the next step to in empirically testing the feasibility is to conduct measurements on fresh fuel assemblies to understand investigate self-attenuation and fresh mixed-oxide (MOX) fuel rodlets so we may better understand extraction of masses for 235 U and 239 Pu. While progressing toward these goals, the collaboration also strongly suggests the continued development of enabling technology such as detector development and algorithm development, which could provide significant performance benefits.

Lead slowing down spectrometry↗

Improvements to Nuclear Data and Its Uncertainties by Theoretical Modeling

This project addresses three important gaps in existing evaluated nuclear data libraries that represent a significant hindrance against highly advanced modeling and simulation capabilities for the Advanced Fuel Cycle Initiative (AFCI). This project will: Develop advanced theoretical tools to compute prompt fission neutrons and gamma-ray characteristics well beyond average spectra and multiplicity, and produce new evaluated files of U and Pu isotopes, along with some minor actinides; Perform state-of-the-art fission cross-section modeling and calculations using global and microscopic model input parameters, leading to truly predictive fission cross-sections capabilities. Consistent calculations for a suite of Pu isotopes will be performed; Implement innovative data assimilation tools, which will reflect the nuclear data evaluation process much more accurately, and lead to a new generation of uncertainty quantification files. New covariance matrices will be obtained for Pu isotopes and compared to existing ones. The deployment of a fleet of safe and efficient advanced reactors that minimize radiotoxic waste and are proliferation-resistant is a clear and ambitious goal of AFCI. While in the past the design, construction and operation of a reactor were supported through empirical trials, this new phase in nuclear energy production is expected to rely heavily on advanced modeling and simulation capabilities. To be truly successful, a program for advanced simulations of innovative reactors will have to develop advanced multi-physics capabilities, to be run on massively parallel super- computers, and to incorporate adequate and precise underlying physics. And all these areas have to be developed simultaneously to achieve those ambitious goals. Of particular interest are reliable fission cross-section uncertainty estimates (including important correlations) and evaluations of prompt fission neutrons and gamma-ray spectra and uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Quantification with Monte Carlo Hauser-Feshbach Calculations of Prompt Fission Neutrons and Gamma Rays

We have performed sensitivity calculations using the CGMF code that implements the statistical Hauser-Feshbach equations in a Monte Carlo fashion to describe the de-excitation of fission fragments by emis sion of prompt neutrons and gamma rays. The specific importance of several input quantities is emphasized. An uncertainty quantification method, considering sources of uncertainty from both model calculations and experiments, is outlined.

Atomic and Nuclear Physics↗

Status on Establishing the Feasibility of Lead Slowing Down Spectroscopy for Direct Measurement of Plutonium in Used Fuel

Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) from next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration to study the feasibility of Lead Slowing Down Spectroscopy. This technique is an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today’s confirmatory assay methods. This paper will present efforts on the development of time-spectral analysis algorithms, fast neutron detector advances, and validation and testing measurements.

LSDS, used fuel, spent fuel, nondestructive assay↗

Progress on Establishing the Feasibility of Lead Slowing Down Spectroscopy for Direct Measurement of Plutonium in Used Fuel

Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) of next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT continues to support a multi-institutional collaboration to address the feasibility of Lead Slowing Down Spectroscopy (LSDS) as an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today’s confirmatory assay methods. An LSDS is comprised of a stack of lead (typically 1-6 m3) in which materials to be measured are placed in the lead and a pulse of neutrons is injected. The neutrons in this pulse lose energy due to inelastic and (subsequently) elastic scattering and the average energy of the neutrons decreases as the time increases by a well-defined relationship. In the interrogation energy region (~0.1-1000 eV) the neutrons have little energy spread (~30%) about the average neutron energy. Due to this characteristic, the energy of the (assay) neutrons can then be determined by measuring the time elapsed since the neutron pulse. By measuring the induced fission neutrons emitted from the used fuel, it is possible to determine isotopic-mass content by unfolding the unique structure of isotopic resonances across the interrogation energy region. This paper will present efforts on the development of time-spectral analysis algorithms, fast neutron detector advances, and validation and testing measurements.

Fission Chambers↗

Lead Slowing Down Spectrometer Status Report

This report documents the progress that has been completed in the first half of FY2012 in the MPACT-funded Lead Slowing Down Spectrometer project. Significant progress has been made on the algorithm development. We have an improve understanding of the experimental responses in LSDS for fuel-related material. The calibration of the ultra-depleted uranium foils was completed, but the results are inconsistent from measurement to measurement. Future work includes developing a conceptual model of an LSDS system to assay plutonium in used fuel, improving agreement between simulations and measurement, design of a thorium fission chamber, and evaluation of additional detector techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗