Engineering Papers⌕ Search

Engineering topics

Danon, Y.

Publications and source records attributed to Danon, Y..

At least 37 records · Page 2

Overview of Nuclear Data Measurement and Analysis at RP [Slides]

This presentation details neutron capture in 54 Fe along with neutron capture yield and γ-ray cascade spectra measurements. The presentation then follows with thermal neutron die-away measurements and concludes with URR improvement to SAMMY.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Zirconium Scattering Sensitivity in Neutron Transport Calculations of Multiplying Systems [Slides]

This presentation touches on motivation and applications of Zirconium. Performance of evaluated libraries on double and quasi differential experiments is considered. Additionally, the performance of evaluated libraries in select ICSBEP benchmarks is considered. Provided is a detailed look in the performance of evaluated libraries in preliminary benchmark configurations for IER-516: Zirconium Test Assembly (ZTA). Conclusions and recommended experiments to satisfy Zirconium scattering nuclear data needs are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quasi-Differential Neutron Scattering Measurements of 181 Ta and Teflon from 1.5 to 20 MeV [Slides]

This presentation covers motivation for the Experiments Performed. Secondly, it touches on upgrades to the Experimental Apparatus for Measurements. Thirdly, it presents quasi-Differential Experimental Methodology a) Pulse Shape Discrimination b) Validation Measurement of Carbon. The presentation concludes with Preliminary Results and Future Studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Energy Quasi - Differential Neutron Emission Measurements of 181 Ta and 19 F [Slides]

This presentation begins with the motivation for performing 181 Ta and 19 F high energy quasi-differential and neutron emission measurements. It then provides a discussion of significant pulse digitization upgrade. The Quasi-Differential methodology and importance for validating nuclear data are provided. Preliminary results from 181 Ta and 19 F are displayed. The presentation concludes with a discussion and future studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Capture and Transmission Measurements and Evaluation of 54 Fe at the RPI LINAC [Slides]

This presentation covers neutron capture and transmission measurements and evaluation of 54 Fe (Iron) at the Rensselaer Polytechnic Insitute (RPI) Linear Accelerator (LINAC). Presentation conclusions find that 54 Fe is near its conclusion, covariance matrix generation is needed for both experiments before data is made available and released (Completion by April 2023). RPI will be conducting a full Resolved Resonance Region (RRR) evaluation following release of data (Completion by September 2023). Additionally, the neutron beam imager shows promise in providing an easy way to align samples in the most intense part of the neutron beam and there will be a new evaluation that will offer improvements in crit safety, shielding, and stellar applications.

07 ISOTOPE AND RADIATION SOURCES↗

Total thermal neutron cross section measurements of hydrogen dense polymers from 0.0005–20 eV

Hydrogen dense polymers, specifically polyethylene, polystyrene, and Plexiglas, have served as neutron moderator and reflector materials in hundreds of separate critical benchmark experiments because of their low cost and abundance of hydrogen. In order to accurately model and simulate these critical benchmarks, the thermal scattering law (TSL) evaluation that governs how neutrons will thermalize must be well understood and rigorously validated. To support this validation, researchers at Rensselaer Polytechnic Institute performed total neutron cross section measurements for high-density polyethylene & polystyrene over the energy range 0.0005–20 eV and for Plexiglas G & Plexiglas G-UVT over the energy range 0.0005–3 eV. Comparisons were made between the measured cross section and that predicted by the ENDF/B-VIII.0 and Oak Ridge National Laboratory/European Spallation Source/Rensselaer Polytechnic Institute TSL evaluations for polyethylene, Plexiglas, and polystyrene, as available. These experiments represent the first total neutron cross section measurements for polystyrene.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Cross Section Measurements At The RPI LINAC [Slides]

This presentation gives an overview of thermal cross section measurements at the RPI LINAC. Work discussed includes novel cold moderator capability for use in extending neutron flux down to 0.0005 eV and total thermal neutron cross section measurements performed for polyethylene, polystyrene, Plexiglas (Lucite), and yttrium hydride over the entire thermal region (0.0005 – 1 eV).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Neutron Cross Section Measurements at the RPI LINAC [Slides]

Cold polyethylene shows adequate capacity for enhancing sub-thermal neutron flux. Cold moderator system produced high quality thermal cross section measurements. Measurements were performed for polyethylene, polystyrene, Plexiglas, yttrium hydride and beryllium and compared with ENDF/B-VIII.0 TSL evaluations. All data reduction for all measurements was finalized. Future work includes completion of necessary journal publications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of sub-thermal neutron flux through cold polyethylene

Total thermal neutron cross section measurements serve as the primary means of validation for thermal neutron scattering kernels, an important quantity for neutron transport calculations. In an effort to improve the quality of thermal neutron scattering kernels, researchers at Rensselaer Polytechnic Institute (RPI) designed and constructed a polyethylene based cold moderation system to enhance neutron flux below 10 meV when coupled with the Enhanced Thermal Target (ETT) at the RPI Gaerttner LINAC. The final design yielded an increase in sub-thermal neutron flux (below 10 meV) by a factor of 4.5 for a moderator temperature of 37.5 K relative to the ETT alone. A further increase to a factor of 6 is expected after a minor geometry modification and decrease in polyethylene temperature to 25 K. This novel capability will be used to conduct total thermal neutron cross section measurements from 0.0005–10 eV for different materials including moderator materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Neutron Scattering from a Copper Sample Using a Quasi-Differential Method in the Region from 2 keV to 20 MeV

Neutron scattering from a copper sample was measured at Rensselaer Polytechnic Institute utilizing the quasi-differential method. The measurement spanned the energy range from 0.5 to 20 MeV using the high-energy scattering system and from 2 keV to 0.5 MeV using the new mid-energy scattering system. Copper was selected as a material of interest to measure due to large discrepancies between experiments and simulations of the Zeus benchmark. The Zeus benchmark consists of a copper reflected highly enriched uranium system, and the angular distribution of copper scattering was thought to potentially be the cause of the discrepancy. The copper measurements found differences in the scattering response particularly in the incident energy region from 1 to 2 MeV for the high-energy measurement and from 2 to 4 keV in the mid-energy system. These differences are particularly noticeable at angles near 90 deg in the high-energy system and back angles in the mid-energy system. Additionally, for ENDF/B-VIII.0 there is a large discrepancy at the forward angle in the energy range around 0.5 MeV. For these reasons, a new evaluation of copper scattering utilizing these results is recommended and perhaps could help to improve the agreement with the Zeus benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mini minutes for a mini CSEWG Virtual mini-CSEWG Meeting 16-19 August, 2021

This meeting is a collaboration meeting of the Cross Section Evaluation Working Group (CSEWG), a collaboration including members from various DOE NNSA and non-NNSA laboratories as well as several university groups that support these laboratory missions. The focus of this meeting will be preparations for the next major release of the ENDF/B nuclear data library. The ENDF/B library is the main neutronics library used in various US neutronics codes such as MCNP and SCALE for advance reactor work, safeguards, stockpile stewardship, etc.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian optimization of generalized data

Direct application of Bayes' theorem to generalized data yields a posterior probability distribution function (PDF) that is a product of a prior PDF of generalized data and a likelihood function, where generalized data consists of model parameters, measured data, and model defect data. The prior PDF of generalized data is defined by prior expectation values and a prior covariance matrix of generalized data that naturally includes covariance between any two components of generalized data. A set of constraints imposed on the posterior expectation values and covariances of generalized data via a given model is formally solved by the method of Lagrange multipliers. Posterior expectation values of the constraints and their covariance matrix are conventionally set to zero, leading to a likelihood function that is a Dirac delta function of the constraining equation. It is shown that setting constraints to values other than zero is analogous to introducing a model defect. Since posterior expectation values of any function of generalized data are integrals of that function over all generalized data weighted by the posterior PDF, all elements of generalized data may be viewed as nuisance parameters marginalized by this integration. One simple form of posterior PDF is obtained when the prior PDF and the likelihood function are normal PDFs. For linear models without a defect this PDF becomes equivalent to constrained least squares (CLS) method, that is, the χ2 minimization method.

Arbanas, Goran↗

CIELO Collaboration Summary Results: International Evaluations of Neutron Reactions on Uranium, Plutonium, Iron, Oxygen and Hydrogen

The CIELO collaboration has studied neutron cross sections on nuclides that significantly impact criticality in nuclear technologies - 235,238 U, 239 Pu, 56 Fe, 16 O and 1 H - with the aim of improving the accuracy of the data and resolving previous discrepancies in our understanding. This multi-laboratory pilot project, coordinated via the OECD/NEA Working Party on Evaluation Cooperation (WPEC) Subgroup 40 with support also from the IAEA, has motivated experimental and theoretical work and led to suites of new evaluated libraries that accurately reflect measured data and also perform well in integral simulations of criticality. This report summarizes our results on cross sections and preliminary work on covariances, and outlines plans for the next phase of this collaboration.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluation of Neutron Reactions on Iron Isotopes for CIELO and ENDF/B-VIII.0

A new suite of evaluations for {sup 54,56,57,58}Fe has been developed in the framework of the CIELO international collaboration. New resolved resonance ranges were evaluated for {sup 54}Fe and {sup 57}Fe, while modifications were applied to resonances in {sup 56}Fe. The low energy part of the {sup 56}Fe file is almost totally based on measurements. At higher energies in {sup 56}Fe and in the whole fast neutron range for minor isotopes the evaluation consists of model predictions carefully adjusted to available experimental data. We also make use of the high quality and well experimentally-constrained dosimetry evaluations from the IRDFF library. Special attention was dedicated to the elastic angular distributions, which were found to affect results of the integral benchmarking. The new set of iron evaluations was developed in concert with other CIELO evaluations and they were tested together in the integral experiments before being adopted for the ENDF/B-VIII.0 library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.0: The 8 th Major Release of the Nuclear Reaction Data Library with CIELO-project Cross Sections, New Standards and Thermal Scattering Data

We describe the new ENDF/B-VIII.0 evaluated nuclear reaction data library. ENDF/B-VIII.0 fully incorporates the new IAEA standards, includes improved thermal neutron scattering data and uses new evaluated data from the CIELO project for neutron reactions on 1 H, 16 O, 56 Fe, 235 U, 238 U and 239 Pu described in companion papers in the present issue of Nuclear Data Sheets. The evaluations benefit from recent experimental data obtained in the U.S. and Europe, and improvements in theory and simulation. Notable advances include updated evaluated data for light nuclei, structural materials, actinides, fission energy release, prompt fission neutron and γ-ray spectra, thermal neutron scattering data, and charged-particle reactions. Integral validation testing is shown for a wide range of criticality, reaction rate, and neutron transmission benchmarks. In general, integral validation performance of the library is improved relative to the previous ENDF/B-VII.1 library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IAEA CIELO Evaluation of Neutron-induced Reactions on 235 U and 238 U Targets

Evaluations of nuclear reaction data for the major uranium isotopes 238 U and 235 U were performed within the scope of the CIELO Project on the initiative of the OECD/NEA Data Bank under Working Party on Evaluation Co-operation (WPEC) Subgroup 40 coordinated by the IAEA Nuclear Data Section. Both the mean values and covariances are evaluated from 10 -5 eV up to 30 MeV. The resonance parameters of 238 U and 235 U were re-evaluated with the addition of newly available data to the existing experimental database. The evaluations in the fast neutron range are based on nuclear model calculations with the code EMPIRE–3.2 Malta above the resonance range up to 30 MeV. 235 U(n,f), 238 U(n,f), and 238 U(n,γ) cross sections and 235 U(n th ,f) prompt fission neutron spectrum (PFNS) were evaluated within the Neutron Standards project and are representative of the experimental state-of-the-art measurements. The Standards cross sections were matched in model calculations as closely as possible to guarantee a good predictive power for cross sections of competing neutron scattering channels. 235 U(n,γ) cross section includes fluctuations observed in recent experiments. 235 U(n,f) PFNS for incident neutron energies from 500 keV to 20 MeV were measured at Los Alamos Chi-Nu facility and re-evaluated using all available experimental data. While respecting the measured differential data, several compensating errors in previous evaluations were identified and removed so that the performance in integral benchmarks was restored or improved. Covariance matrices for 235 U and 238 U cross sections, angular distributions, spectra and neutron multiplicities were evaluated using the GANDR system that combines experimental data with model uncertainties. Unrecognized systematic uncertainties were considered in the uncertainty quantification for fission and capture cross sections above the thermal range, and for neutron multiplicities. Evaluated files were extensively benchmarked to ensure good performance in reactor calculations and fusion-related systems. New comprehensive evaluations show excellent agreement with available differential data and integral performance better than current evaluated data libraries, and represent a step forward in a quest for better nuclear data for applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CSEWG 2017 Minutes

These are the minutes of the 2017 Cross Section Evaluation Working Group (CSEWG). This meeting corresponds to the 50±1th anniversary of CSEWG. The uncertainty on the anniversary reflects the fact that CSEWG was formed in 1966 yet the first ENDF library was published in 1968. Despite the uncertainty on the date of the anniversary, this meeting is an especially auspicious one: this is the last meeting before the release of ENDF/B-VIII.0. This meeting is devoted both to closing out the last open issues before releasing the library and to looking toward the future. The careful reader should note that there are no closing statements in this meeting. This is in a way symbolic of the fact that since ENDF/B is always improving, our work here will never truly be done.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗