Engineering Papers⌕ Search

Engineering topics

D’Incecco, M.

Publications and source records attributed to D’Incecco, M..

Search for dark matter annual modulation with DarkSide-50

Dark matter may induce an event in an Earth-based detector, and its event rate is predicted to show an annual modulation as a result of the Earth’s orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above 40 eV ee , the lowest threshold ever achieved in such a search. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for low mass dark matter in DarkSide-50: the bayesian network approach

Abstract We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there is no need to morph signal and background spectra as a function of nuisance parameters. By expressing the problem in terms of Bayesian Networks, we have developed an inference algorithm based on a Markov Chain Monte Carlo to calculate the posterior probability. A clever description of the detector response model in terms of parametric matrices allows us to study the impact of systematic variations of any parameter on the final results. Our approach not only provides the desired information on the parameter of interest, but also potential constraints on the response model. Our results are consistent with recent published analyses and further refine the parameters of the detector response model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50

DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV=c 2 mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows us to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to ~180 eV er , exploiting 37 Ar and 39 Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Further, we present a model-dependent determination of the ionization response to nuclear recoils down to ~500 eV nr , the lowest ever achieved in liquid argon, using in situ neutron calibration sources and external datasets from neutron beam experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The “standard” EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms (“neutral bremsstrahlung”, NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effective field theory interactions for liquid argon target in DarkSide-50 experiment

We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 ± 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between 2.4×10-45 cm2 and 2.3×10-42 cm2 (8.9 ×10-45 cm2 and 6.0 ×10-42 cm2) for WIMPs of mass of 100 GeV/c2 (1000 GeV/c2) at 90% confidence level.

Agnes, P↗

Measurement of the ion fraction and mobility of 218Po produced in 222Rn decays in liquid argon

We report measurements of the charged daughter fraction of 218Po as a result of the 222Rn alpha decay, and the mobility of 218Po+ ions, using radon-polonium coincidences from the 238U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of 218Po that is charged is found to be 0.37 ± 0.03 and the mobility of 218Po+ is (8.6 ± 0.1) × 10-4 cm2/Vs.

Agnes, P↗

DarkSide-50 532-day dark matter search with low-radioactivity argon

The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon time projection chamber operating at Laboratori Nazionali del Gran Sasso. This paper reports on the blind analysis of a (16 660 ± 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. Additionally, we find no events in the dark matter selection box and set a 90% C.L. upper limit on the dark matter–nucleon spin-independent cross section of 1.14×10 -44 cm 2 (3.78 × 10 -44 cm 2 , 3.43×10 -43 cm 2 ) for a WIMP mass of 100 GeV/c 2 (1 TeV/c 2 , 10 TeV/c 2 ).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on Sub-GeV Dark-Matter–Electron Scattering from the DarkSide-50 Experiment

Here, we present new constraints on sub-GeV dark matter particles scattering off electrons based on 6780.0 kg d of data collected with the DarkSide-50 dual-phase argon time projection chamber. This analysis uses electroluminescence signals due to ionized electrons extracted from the liquid argon target. The detector has a very high trigger probability for these signals, allowing for an analysis threshold of three extracted electrons, or approximately 0.05 keVee. We calculate the expected recoil spectra for dark matter-electron scattering in argon and, under the assumption of momentum-independent scattering, improve upon existing limits from XENON10 for dark-matter particles with masses between 30 and 100 MeV/c 2 .

79 ASTRONOMY AND ASTROPHYSICS↗

Low-mass Dark Matter Search with the DarkSide-50 Experiment

We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and is almost entirely accounted for by known background sources. We obtain a 90% C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section of dark matter WIMPs on nucleons, extending the exclusion region for dark matter below previous limits in the range 1.8-6 GeV/c^2.

Agnes, P↗

Electroluminescence pulse shape and electron diffusion in liquid argon measured in a dual-phase TPC

Here, we report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics $^{39}$Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs. The derived S2 pulse shape is fit to events from the uppermost portion of the TPC in order to characterize the radial dependence of the signal. The results are provided as inputs to the measurement of the longitudinal diffusion constant DL, which we find to be (4.12 $\pm$ 0.04) cm$^2$/s for a selection of 140keV electron recoil events in 200V/cm drift field and 2.8kV/cm extraction field. To study the systematics of our measurement we examine datasets of varying event energy, field strength, and detector volume yielding a weighted average value for the diffusion constant of (4.09 $\pm$ 0.09) cm$^2$ /s. The measured longitudinal diffusion constant is observed to have an energy dependence, and within the studied energy range the result is systematically lower than other results in the literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DarkSide-20k: A 20 tonne two-phase LAr TPC for direct dark matter detection at LNGS

Abstract. Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LAr TPC) with an active (fiducial) mass of 23 t (20 t). This paper describes a preliminary design for the experiment, in which the DarkSide-20k LAr TPC is deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). This preliminary design provides a baseline for the experiment to achieve its physics goals, while further development work will lead to the final optimization of the detector parameters and an eventual technical design. Operation of DarkSide-50 demonstrated a major reduction in the dominant 39Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of > 3 × 109 is achievable. This, along with the use of the veto system and utilizing silicon photomultipliers in the LAr TPC, are the keys to unlocking the path to large LAr TPC detector masses, while maintaining an experiment in which less than < 0.1 events (other than ?-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured in situ, giving sensitivity to WIMP-nucleon cross sections of 1.2×10 -47 cm2 (1.1×10 -46 cm2) for WIMPs of 1TeV/c2 (10TeV/c2) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background.

Aalseth, Craig E.↗

The DarkSide experiment: Present status and future

Here, DarkSide is a multi-stage program devoted to direct searches of Dark Matter particles with detectors based on double phase liquid Argon Time Projection Chamber. The DarkSide-50 setup is running underground at the Laboratori Nazionali del Gran Sasso. First it was operated with Atmospheric Argon and during that run (1422 ± 67) kg×d of truly background-free exposure has been accumulated. Obtained data made it possible to set a 90% C.L. upper limit on the WIMP-nucleon cross section of 6.1 × 10 –44 cm 2 (for a WIMP mass of 100 GeV/c 2 ). Presently the detector is filled with Underground Argon, which is depleted in 39 Ar by a factor of (1.4 ± 0.2)×10 3 with respect to Atmospheric Argon. Acquired so far (2616 ± 43) kg×d (71 live days) in combination with the data from the Atmospheric Argon run give us the 90% C.L. upper limit on the WIMP-nucleon spin-independent cross section of 2.0×10 –44 cm 2 for a WIMP mass of 100 GeV/c 2 . Up to date this is the best limit obtained with an argon target.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The DarkSide awakens

Here, the DarkSide program at LNGS aims to perform background-free WIMP searches using two phase liquid argon time projection chambers, with the ultimate goal of covering all parameters down to the so-called neutrino floor. One of the distinct features of the program is the use of underground argon with has a reduced content of the radioactive 39 Ar compared to atmospheric argon. The DarkSide Collaboration is currently operating the DarkSide-50 experiment, the first such WIMP detector using underground argon. Operations with underground argon indicate a suppression of 39 Ar by a factor (1.4 ± 0.2) × 10 3 relative to atmospheric argon. The new results obtained with DarkSide-50 and the plans for the next steps of the DarkSide program, the 20t fiducial mass DarkSide-20k detector and the 200 t fiducial Argo, are reviewed in this proceedings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results From the First Use of Low Radioactivity Argon in a Dark Matter Search

Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using a two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar39 at a level reduced by a factor (1.4±0.2)×103 relative to atmospheric argon. We report a background-free null result from (2616±43) kg d of data, accumulated over 70.9 live days. When combined with our previous search using an atmospheric argon, the 90% C.L. upper limit on the WIMP-nucleon spin-independent cross section, based on zero events found in the WIMP search regions, is 2.0×10-44 cm2 (8.6×10-44 cm2, 8.0×10-43 cm2) for a WIMP mass of 100 GeV/c2 (1 TeV/c2, 10 TeV/c2).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The DarkSide Multiton Detector for the Direct Dark Matter Search

A wide range of astronomical evidence implies the existence of Dark Matter, but as yet the nature of this major component of the Universe is completely unknown. A leading candidate explanation is that Dark Matter is composed of Weakly Interacting Massive Particles (WIMPs) formed in the early universe and gravitationally clustered together with the standard baryonic matter. Such WIMPs could in principle be detected through their collisions with ordinary nuclei in a sensitive target, producing observable low-energy (<100 keV) nuclear recoils. The predicted collision rates are very low and require ultra-low background detectors with large (0.1 { 10 tons) target masses, located in deep underground sites to reduce the background produced by neutrons from cosmic ray muons [1{4].

Dark Matter↗