Engineering PapersSearch

Engineering topics

Curreri, J. S.

Publications and source records attributed to Curreri, J. S..

Motor starting a Brayton cycle power conversion system using a static inverter

The power conversion module of a 2- to 15-kWe Brayton engine was motor started using a three-phase, 400-hertz static inverter as the power source. Motor-static tests were conducted for initial gas loop pressures of 10, 14, and 17 N/sq cm (15, 20, and 25 psia) over a range of initial turbine inlet temperatures from 366 to 550 K (200 to 530 F). The data are presented to show the effects of temperature and pressure on the motor-start characteristics of the rotating unit. Electrical characteristics during motoring are also discussed.

Curreri, J. S.

Low frequency sinusoidal pressure generator

Low frequency pressure generator is built to provide sinusoidal driving function in frequency range from 0.05 to 50 Hz for frequency response testing of pressure transducers used in liquid-filled systems. Generator consists of piston-in-cylinder, scotch-yoke mechanism machined into piston, and adjustable eccentric.

Curreri, J. S.

Preliminary performance of a 4.97-inch radial turbine operating in a Brayton power system with a helium-xenon gas mixture

The performance characteristics of the Brayton-rotating-unit's 4.97-inch radial turbine were investigated with the turbine part of a power conversion system. The following system parameters were varied: turbine inlet temperature from 1200 to 1600 F, compressor inlet temperature from 60 to 120 F, compressor outlet pressure from 20 to 45 psia, and shaft speed from 90-110 percent of rated speed (36000 rpm). The working fluid of the system was a gas mixture of helium-xenon with a nominal molecular weight of 83.8. Test results indicate that changes in system conditions have little effect on the turbine efficiency. At the design turbine inlet temperature of 1600 F and compressor inlet temperature of 80 F, an average turbine efficiency of 91 percent was obtained.

Leroy, M. J., Jr.