Engineering Papers⌕ Search

Engineering topics

Curis, Emmanuel

Publications and source records attributed to Curis, Emmanuel.

Robust framework and software implementation for fast speciation mapping

One of the greatest benefits of synchrotron radiation is the ability to perform chemical speciation analysis through X-ray absorption spectroscopies (XAS). XAS imaging of large sample areas can be performed with either full-field or raster-scanning modalities. A common practice to reduce acquisition time while decreasing dose and/or increasing spatial resolution is to compare X-ray fluorescence images collected at a few diagnostic energies. In this work, several authors have used different multivariate data processing strategies to establish speciation maps. Furthermore, the theoretical aspects and assumptions that are often made in the analysis of these datasets are focused on. A robust framework is developed to perform speciation mapping in large bulk samples at high spatial resolution by comparison with known references. Two fully operational software implementations are provided: a user-friendly implementation within the MicroAnalysis Toolkit software, and a dedicated script developed under the R environment. The procedure is exemplified through the study of a cross section of a typical fossil specimen. Additionally, the algorithm provides accurate speciation and concentration mapping while decreasing the data collection time by typically two or three orders of magnitude compared with the collection of whole spectra at each pixel. Whereas acquisition of spectral datacubes on large areas leads to very high irradiation times and doses, which can considerably lengthen experiments and generate significant alteration of radiation-sensitive materials, this sparse excitation energy procedure brings the total irradiation dose greatly below radiation damage thresholds identified in previous studies. This approach is particularly adapted to the chemical study of heterogeneous radiation-sensitive samples encountered in environmental, material, and life sciences.

47 OTHER INSTRUMENTATION↗

Eligibility for Renal Denervation: Anatomical Classification and Results in Essential Resistant Hypertension

PurposeTo classify the renal artery (RA) anatomy based on specific requirements for endovascular renal artery denervation (RDN) in patients with drug-resistant hypertension (RH).Materials and MethodsThe RA anatomy of 122 consecutive RH patients was evaluated by computed tomography angiography and classified as two types: A (main RA ≥20 mm in length and ≥4.0 mm in diameter) or B (main RA <20 mm in length or main RA <4.0 mm in diameter). The A type included three subtypes: A1 (without accessory RAs), A2 (with accessory RAs <3.0 mm in diameter), and A3 (with accessory RAs ≥3.0 mm in diameter]. A1 and A2 types were eligible for RDN with the Simplicity Flex catheter. Type B included twi subtypes based on the main RA length and diameter. Patients were accordingly classified into three eligibility categories: complete (CE; both RAs were eligible), partial (PE; one eligible RA), and noneligibility (NE; no eligible RA).ResultsBilateral A1 type was the most prevalent and was observed in 48.4 % of the patients followed by the A1/A2 type (18 %). CE, PE, and NE were observed in 69.7, 22.9, and 7.4 % of patients, respectively. The prevalence of accessory RAs was 41 %.ConclusionsOf RH patients, 30.3 % were not eligible for bilateral RDN with the current Simplicity Flex catheter. This classification provides the basis for standardized reporting to allow for pooling of results of larger patient cohorts in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗