Engineering Papers⌕ Search

Engineering topics

Cooper, Matthew W.

Publications and source records attributed to Cooper, Matthew W..

34 records · Page 2

High performance blue-emitting organic light-emitting diodes from thermally activated delayed fluorescence: A guest/host ratio study

Emitters displaying thermally activated delayed fluorescence (TADF) can drive highly efficient organic light-emitting diodes (OLEDs). Such emitters are usually incorporated into the emissive layer (EML) at a relatively low concentration (<20 wt. %) with respect to a host material, a guest-host method inherited from conventional fluorescent or phosphorescent OLEDs. In this work, detailed studies on OLEDs, in which the concentration of oBFCzTrz (a blue-emitter displaying TADF) in a DPEPO host was varied from 8 to 100 wt. %, reveals that oBFCzTrz displays ambipolar transport and limited fluorescence-quenching due to aggregation. For instance, a neat film of oBFCzTrz maintains a photoluminescence quantum yield of 82%. We determine that OLEDs with an EML having an oBFCzTrz concentration of 50 wt. % in DPEPO yield a maximum external quantum efficiency (EQE) of 25.5% with an EQE roll-off of 10% in the range from 10 to 1000 cd/m 2 and Commission Internationale de l'Eclairage color coordinates of (0.20, 0.44). OLEDs with smaller or larger oBFCzTrz concentrations display smaller maximum EQE values. OLEDs with a neat oBFCzTrz EML display a maximum EQE of 14.0%. Finally, time-resolved electroluminescent decay studies, and analysis using a simple model, reveal significant differences in transport, trapping, and recombination in these devices.

36 MATERIALS SCIENCE↗

Requirements for Xenon International (Rev. 2)

This document defines the requirements for the new Xenon International radioxenon system. The output of this project will be a Pacific Northwest National Laboratory (PNNL) developed prototype and a manufacturer-developed production prototype. The two prototypes are intended to be as close to matching as possible; this will be facilitated by overlapping development cycles and open communication between PNNL and the manufacturer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Xenon International Overview

The Xenon International system is a fully automated unattended system designed to collect, separate, purify, quantify, and perform nuclear counting on radioxenon isotopes as well as transmit data using two-way communications (Figure 1). Xenon International is designed to stringent requirements that make it an high performance next-generation-system for use in nuclear explosion monitoring networks such as the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Minimum Detectable Concentration and Concentration Calculations

This report highlights the work that has been completed on concentration calculations, uncertainties and minimum detectable concentration (MDC) for radioxenon collection systems. A discussion on the theory behind MDC calculations is given. In addition, regions of interest (ROI) and their role in correcting for both memory effects and interference terms are given in detail. A detailed derivation and walkthrough of the calculation is given with some discussion at each stage of the equation. Finally, some specific examples are given with typical numbers from an ARSA system as a guide.

61 RADIATION PROTECTION AND DOSIMETRY↗

A program to generate simulated radioxenon beta–gamma data for concentration verification and validation and training exercises

Abstract Several hundred simulated radioxenon beta-gamma data files were developed to assist in evaluating the performance and results from radioxenon concentration calculation analysis at the International Data Center (IDC) and other National Data Centers (NDC). PNNL developed a Beta-Gamma Simulator (BGSim) that incorporated GEANT-modeled data sets from radioxenon decay chains, as well as functionality to use nuclear detector-acquired data sets to create new beta-gamma spectra with varying amounts of background, 133Xe, 131mXe, 133mXe, 135Xe, and 222Rn and its decay products. The program has been implemented on a web-based applications platform and allows the user to create very specific data sets that incorporate most of the operational parameters for the current beta-gamma systems deployed in the International Monitoring System (IMS) and the On-site Inspection (OSI) equipment. After an initial beta-gamma simulations program was developed, additional uses began to be identified for the program output: training sets of two-dimensional spectra for data analysts at the IDC and other NDC, spectra for exercises such as the Integrated Field Exercise 2014 (IFE14) held in Jordan at the Dead Sea, and testing new analysis methods and algorithms

custom datasets↗

Radioxenon detector calibration spike production and delivery systems

Abstract Beta-Gamma coincidence radioxenon detectors must be calibrated for each of the four-radioxenon isotopes (135Xe, 133Xe, 133mXe, and 131mXe). Without a proper calibration, there is potential for the misidentification of the amount of each isotope detected. It is important to accurately determine the amount of each radioxenon isotope, as the ratios can be used to distinguish between an anthropogenic source and a nuclear explosion. We have developed a xenon calibration system (XeCalS) that produces calibration spikes of known activity and pressure for field calibration of detectors. The activity concentrations of these calibration spikes are measured using a beta-gamma coincidence detector and a high purity germanium (HPGe) detector. We will present the results from the development and commissioning of XeCalS, along with the future plans for a portable spike implementation system.

beta-gamma coincidence detector↗

Metastable Radioxenon Verification Laboratory (MRVL) Year-End Report

This is the year end report that is due to the client. The MRVL system is designed to measure multiple radioxenon isotopes ( 135 Xe, 133 Xe, 133 mXe and 133 mXe) simultaneously. The system has 12 channels to load samples and make nuclear measurements. Although the MRVL system has demonstrated excellent stability in measurements of Xe-133 and Xe-135 over the year of evaluation prior to delivery, there has been concern about system stability over measurements performed on samples with orders of magnitude different radioactivity, and samples containing multiple isotopes. To address these concerns, a series of evaluation test have been performed at the end-user laboratory. The evaluation was performed in two separate phases. Phase 1 made measurements on isotopically pure Xe-133 from high radioactivity down to the system background levels of activity, addressing the potential count rate dependencies when activities change from extreme high to very low. The second phase performed measurements on samples containing multiple isotopes (Xe-135, Xe-133 and Xe-133m), and addressed concerns about the dependence of isotopic concentrations on the presence of additional isotopes. The MRVL showed a concentration dependence on the Xe-133 due to the amount of Xe-133m that was in the sample. The dependency is due to the decay of Xe-133m into Xe-133. This document focuses on the second phase and will address the analysis used to account for ingrowth of Xe-133 from Xe-133m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source Term Estimation of Radioxenon Released from the Fukushima Dai-ichi Nuclear Reactors Using Measured Air Concentrations and Atmospheric Transport Modeling

Systems designed to monitor airborne radionuclides released from underground nuclear explosions detected radioactive fallout from the Fukushima Daiichi nuclear accident in March 2011. Atmospheric transport modeling (ATM) of plumes of noble gases and particulates were performed soon after the accident to determine plausible detection locations of any radioactive releases to the atmosphere. We combine sampling data from multiple International Modeling System (IMS) locations in a new way to estimate the magnitude and time sequence of the releases. Dilution factors from the modeled plume at five different detection locations were combined with 57 atmospheric concentration measurements of 133-Xe taken from March 18 to March 23 to estimate the source term. This approach estimates that 59% of the 1.24×1019 Bq of 133-Xe present in the reactors at the time of the earthquake was released to the atmosphere over a three day period. Source term estimates from combinations of detection sites have lower spread than estimates based on measurements at single detection sites. Sensitivity cases based on data from four or more detection locations bound the source term between 35% and 255% of available xenon inventory.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Absolute Efficiency Calibration of a Beta-Gamma Detector

Abstract- Identification and quantification of nuclear events such as the Fukushima reactor failure and nuclear explosions rely heavily on the accurate measurement of radioxenon releases. One radioxenon detection method depends on detecting beta-gamma coincident events paired with a stable xenon measurement to determine the concentration of a plume. Like all measurements, the beta-gamma method relies on knowing the detection efficiency for each isotope measured. Several methods are commonly used to characterize the detection efficiency for a beta-gamma detector. The most common method is using a NIST certified sealed source to determine the efficiency. A second method determines the detection efficiencies relative to an already characterized detector. Finally, a potentially more accurate method is to use the expected sample to perform an absolute efficiency calibration; in the case of a beta-gamma detector, this relies on radioxenon gas samples. The complication of the first method is it focuses only on the gamma detectors and does not offer a solution for determining the beta efficiency. The second method listed is not similarly constrained, however it relies on another detector to have a well-known efficiency calibration. The final method using actual radioxenon samples to make an absolute efficiency determination is the most desirable, but until recently it was not possible to produce all four isotopically pure radioxenon. The production, by University of Texas (UT), of isotopically pure radioxenon has allowed the beta-gamma detectors to be calibrated using the absolute efficiency method. The first four radioxenon isotope calibration will be discussed is this paper.

absolute efficiency calibration beta-gamma↗

A ROBUST ABSOLUTE DETECTION EFFICIENCY CALIBRATION METHOD UTILIZING BETA/GAMMA COINCIDENCE SIGNATURES AND ISOTOPICALLY PURIFIED NEUTRON ACTIVATED RADIOXENON ISOTOPES

Efforts to calibrate the absolute efficiency of gas cell radiations detectors have utilized a number of methodologies which allow adequate calibration but are time consuming and prone to a host of difficult-to-determine uncertainties. A method that extrapolates the total source strength from the measured beta and gamma gated beta coincidence signal was developed in the 1960’s and 1970’s. It has become clear that it is possible to achieve more consistent results across a range of isotopes and a range of activities using this method. Even more compelling is the ease with which this process can be used on routine samples to determine the total activity present in the detector. Additionally, recent advances in the generation of isotopically pure radioxenon samples of Xe-131m, Xe-133, and Xe-135 have allowed these measurement techniques to achieve much better results than would have been possible before when using mixed isotopic radioxenon source. This paper will discuss the beta/gamma absolute detection efficiency technique that utilizes several of the beta-gamma decay signatures to more precisely determine the beta and gamma efficiencies. It will than compare these results with other methods using pure sources of Xe-133, Xe-131m, and Xe-135 and a Xe-133/Xe-133m mix.

Beta-gamma↗

A TREATMENT OF THE MEASUREMENT UNCERTAINTY FOR XENON VOLUME QUANTIFICATION

Treaty monitoring gas measurement systems that measure radioxenon typically report results as an activity concentration, which is the measured radioxenon activity divided by the amount of stable xenon present. While the nuclear activity uncertainty has been studied in detail and is driven primarily by counting statistics, the uncertainty for the volume measurement has been considered in less detail. A framework for a more complete consideration of the uncertainty for the volume measurement has been developed. This type of analysis can help drive the system requirements for the volume quantification while the system is still being developed or added to advanced fielded systems. Depending on the accuracy requirements for the activity concentration, the volume quantification measurement and analysis can be developed to a suitably high level of accuracy. Nominally, it is best to have the activity concentration uncertainty limited by the uncertainty of the activity measurement because it tends to be fundamentally limited by the counting statistics. Volume quantification should be performed more accurately so that the activity concentration uncertainty is not degraded from the counting statistics. This paper will describe in detail a stable gas quantification uncertainty analysis for a xenon monitoring system.

Harper, Warren W.↗

First Four-Isotope Calibration of a Beta-Gamma Quad Detector

Beta-gamma coincidence detectors used for radioxenon detection are non-standard detector types, but still require energy and efficiency calibration. There are several methods that are commonly used to perform a detector calibration. ? NIST certified sealed source ? Relative measurement to compare to a calibrated detector ? Absolute efficiency calibration based on radioxenon gas samples. The method using actual radioxenon samples to make an absolute efficiency determination is the most desirable, but until recently it was not possible to produce all four isotopically pure radioxenon. The first four radioxenon isotope calibration is outlined here.

Cooper, Matthew W.↗

Initial Beta-Gamma Nuclear Detector Background Study

Detection of underground nuclear explosions and, more recently, nuclear reactor events is of great national interest. These measurements are most often made by determining the concentration of radioactive noble gases in the atmosphere. Currently there are several ground-based systems capable of making radioxenon gas measurements. The measurement is often close to the detection limit, so understanding the parameters and features that limit the measurement is very important. A preliminary study of the detection limit has been performed using a -Quad detector designed at Pacific Northwest National Laboratory (PNNL). The initial study has concentrated on the measuring the ambient radioactive background. By making several background measurements while varying the detector, shielding it is possible to identify whether the ambient background is internal or external to the detector. Furthermore, internal background contributions can be potentially reduced by selecting alternative low-background materials, while external background can be reduced by increasing the active or passive shielding present. By reducing the background contributions, it is possible to improve the detection limit and therefore the likelihood of positively identifying a nuclear test.

Cooper, Matthew W.↗

Measurements of Worldwide Radioxenon Backgrounds - The "EU" Project

Under the Comprehensive Nuclear-Test-Ban Treaty (CTBT), radioactive xenon (radioxenon) measurements are one of the principle techniques used to detect nuclear underground nuclear explosions, and specifically, the presence of one or more radioxenon isotopes allows one to determine whether a suspected event was a nuclear explosion or originated from an innocent source. During the design of the International Monitoring System (IMS), which was designed as the verification mechanism for the Treaty, it was determined that radioxenon measurements should be performed at 40 or more stations worldwide. At the time of the design of the IMS, however, very few details about the background of the xenon isotopes was known and it is now recognized that the backgrounds were probably evolving anyhow. This paper lays out the beginning of a study of the worldwide concentrations of xenon isotopes that can be used to detect nuclear explosions and several sources that also release radioxenons, and will have to be accounted for during analysis of atmospheric levels. Although the global concentrations of the xenon isotopes are the scope of a much larger activity that could span over several years, this study measures radioxenon concentrations in locations where there was either very little information or there was a unique opportunity to learn more about emissions from known sources. The locations where radioxenon levels were measured and reported are included.

background measurements↗