Engineering topics
Conover, David
Publications and source records attributed to Conover, David.
Energy Storage System Deployment Why Codes and Standards are Relevant and What is Happening.
Abstract not provided.
Energy Storage System Safety Working Group Activities Achievements and Next Steps.
Abstract not provided.
Energy Storage System Overview and Addressing System Safety.
Abstract not provided.
Safety Outreach and Incident Response Stakeholder Strategy
The objective of this document is to set out a strategy to reach all stakeholders that can impact the timely deployment of safe stationary energy storage systems in the built environment with information on ESS technology and safety that is relevant to their role in deployment of the technology.
Energy Storage Safety: Guidelines Developed by the Energy Storage Integration Council for Distributed-Connected Systems
Abstract not provided.
Measuring and Expressing the Performance of Energy Storage Systems.
Abstract not provided.
Energy Storage System Overview: Addressing System Safety for Code Officials and First Responders.
Abstract not provided.
Copy of Update on DOE OE Activities to Support Safe Energy Storage System Installations.
Abstract not provided.
Protocol for uniformly measuring and expressing the performance of energy storage systems.
The U.S. Department of Energy s Energy Storage Systems (ESS) Program, through the support of Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL), facilitated the development of the protocol provided in this report. The focus of the protocol is to provide a uniform way of measuring, quantifying, and reporting the performance of ESSs in various applications; something that does not exist today and, as such, is hampering the consideration and use of this technology in the market. The availability of an application-specific protocol for use in measuring and expressing performance-related metrics of ESSs will allow technology developers, power-grid operators and other end-users to evaluate the performance of energy storage technologies on a uniform and comparable basis. This will help differentiate technologies and products for specific application(s) and provide transparency in how performance is measured. It also will assist utilities and other consumers of ESSs to make more informed decisions as they consider the potential application and use of ESSs, as well as form the basis for documentation that might be required to justify utility investment in such technologies.
Dynamic cone beam CT angiography of carotid and cerebral arteries using canine model
Purpose: This research is designed to develop and evaluate a flat-panel detector-based dynamic cone beam CT system for dynamic angiography imaging, which is able to provide both dynamic functional information and dynamic anatomic information from one multirevolution cone beam CT scan. Methods: A dynamic cone beam CT scan acquired projections over four revolutions within a time window of 40 s after contrast agent injection through a femoral vein to cover the entire wash-in and wash-out phases. A dynamic cone beam CT reconstruction algorithm was utilized and a novel recovery method was developed to correct the time-enhancement curve of contrast flow. From the same data set, both projection-based subtraction and reconstruction-based subtraction approaches were utilized and compared to remove the background tissues and visualize the 3D vascular structure to provide the dynamic anatomic information. Results: Through computer simulations, the new recovery algorithm for dynamic time-enhancement curves was optimized and showed excellent accuracy to recover the actual contrast flow. Canine model experiments also indicated that the recovered time-enhancement curves from dynamic cone beam CT imaging agreed well with that of an IV-digital subtraction angiography (DSA) study. The dynamic vascular structures reconstructed using both projection-based subtraction and reconstruction-based subtraction were almost identical as the differences between them were comparable to the background noise level. At the enhancement peak, all the major carotid and cerebral arteries and the Circle of Willis could be clearly observed. Conclusions: The proposed dynamic cone beam CT approach can accurately recover the actual contrast flow, and dynamic anatomic imaging can be obtained with high isotropic 3D resolution. This approach is promising for diagnosis and treatment planning of vascular diseases and strokes.
Compliance Verification Paths for Residential and Commercial Energy Codes
Conformity assessment is a term used to describe the processes followed to demonstrate that a product, service, management system, or body meets specified requirements, such as standards, codes, laws, regulations, or other criteria. With respect to energy codes, conformity assessment includes all activities and tasks undertaken by any number of entities to ensure that the provisions of an adopted energy code are achieved at a designated point in time. This report identifies and discusses conformity assessment activities and provides guidance for developing new or adjusting existing ways of verifying compliance. In addition, this report looks at different ways to ensure that the energy-efficiency goals of an adopted code or standard are achieved.