Engineering Papers⌕ Search

Engineering topics

Conley, R

Publications and source records attributed to Conley, R.

At least 19 records

Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200

We report the observation of two-neutrino double-beta decay in {sup 136}Xe with T{sub 1/2} = 2.11 {+-} 0.04(stat) {+-} 0.21(syst) x 10{sup 21} yr. This second-order process, predicted by the standard model, has been observed for several nuclei but not for {sup 136}Xe. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrinoless double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multilayer Laue Lens Growth at NSLS-II

The new NSLS-II deposition laboratory has been commissioned to include a variety of thin-film characterization equipment and a next-generation deposition system. The primary goal for this effort is R&D on the multilayer Laue lens (MLL), which is a new type of x-ray optic with the potential for an unprecedented level of x-ray nano-focusing. This unique deposition system contains many design features in order to facilitate growth of combined depth-graded and laterally graded multilayers with precise thickness control over many thousands of layers, providing total film growth in one run of up to 100 {micro}m thick or greater. A precision in-vacuum linear motor servo system raster scans a substrate over an array of magnetrons with shaped apertures at well-defined velocities to affect a multilayer coating. The design, commissioning, and performance metrics of the NSLS-II deposition system will be discussed. Latest growth results of both MLL and reflective multilayers in this machine will be presented.

36 MATERIALS SCIENCE↗

Characterization of Electron Microscopes with Binary Pseudo-random Multilayer Test Samples

Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [1] and [2] and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi2/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard X-ray Nano Patterning using a Sectioned Multilayer

We report a hard x-ray patterning capable of drawing lines with a width below 100 nm using x-rays at 0.165 nm. A specially prepared mask based on multilayer growth technology was used as an x-ray mask effectively. The x-ray Talbot effect in near field was investigated and utilized in the patterning. Since multilayers with a few nanometer layer spacing are readily available, the proposed hard x-ray nano patterning, free of the limit imposed by the Rayleigh criterion in optical range, can potentially be an ultimate optical lithography technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of Large Area APDs for the EXO-200 Detector

EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169 K - the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synchrotron X-ray tests of an L-shaped laterally graded multilayer mirror for the analyzer system of the ultra-high-resolution IXS spectrometer at NSLS-II

Characterization and testing of an L-shaped laterally graded multilayer mirror are presented. This mirror is designed as a two-dimensional collimating optics for the analyzer system of the ultra-high-resolution inelastic X-ray scattering (IXS) spectrometer at National Synchrotron Light Source II (NSLS-II). The characterization includes point-to-point reflectivity measurements, lattice parameter determination and mirror metrology (figure, slope error and roughness). Here, the synchrotron X-ray test of the mirror was carried out reversely as a focusing device. The results show that the L-shaped laterally graded multilayer mirror is suitable to be used, with high efficiency, for the analyzer system of the IXS spectrometer at NSLS-II.

36 MATERIALS SCIENCE↗

Calibration of the Modulation Transfer Function of Surface Profilometers with Binary Pseudorandom Test Standards: Expanding the Application Range to Fizeau Interferometers and Electron Microscopes

A modulation transfer function (MTF) calibration method based on binary pseudorandom (BPR) gratings and arrays has been proven to be an effective MTF calibration method for interferometric microscopes and a scatterometer. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 in. phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to the BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of electron microscopes with binary pseudo-random multilayer test samples

Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binarypseudo-random (BPR) gratings and arrays has been suggested and and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer. Here we describe the details of development of binarypseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi{sub 2}/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML testsamples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

36 MATERIALS SCIENCE↗

Observation of the Talbot effect using broadband hard x-ray beam

We demonstrated the Talbot effect using a broadband hard x-ray beam ({Delta}{lambda}/{lambda} {approx}1). The exit wave-field of the x-ray beam passing through a grating with a sub micro-meter scale period was successfully replicated and recorded at effective Talbot distance, Z{sub T}. The period was reduced to half at Z{sub T}/4 and 3/4Z{sub T}, and the phase reversal was observed at Z{sub T}/2. The propagating wave-field recorded on photoresists was consistent with a simulated result.

43 PARTICLE ACCELERATORS↗

Pressure-dependent transition from atoms to nanoparticles in magnetron sputtering: Effect on WSi{sub 2} film roughness and stress

We report on the transition between two regimes from several-atom clusters to much larger nanoparticles in Ar magnetron sputter deposition of WSi{sub 2}, and the effect of nanoparticles on the properties of amorphous thin films and multilayers. Sputter deposition of thin films is monitored by in situ x-ray scattering, including x-ray reflectivity and grazing incidence small-angle x-ray scattering. The results show an abrupt transition at an Ar background pressure P{sub c}; the transition is associated with the threshold for energetic particle thermalization, which is known to scale as the product of the Ar pressure and the working distance between the magnetron source and the substrate surface. Below P{sub c} smooth films are produced while above P{sub c} roughness increases abruptly, consistent with a model in which particles aggregate in the deposition flux before reaching the growth surface. The results from WSi{sub 2} films are correlated with in situ measurement of stress in WSi{sub 2}/Si multilayers, which exhibits a corresponding transition from compressive to tensile stress at P{sub c}. The tensile stress is attributed to coalescence of nanoparticles and the elimination of nanovoids.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WSi2/Si Multilayer Sectioning by Reactive Ion Etching for Multilayer Laue Lens Fabrication

SPIE Conference paper/talk presentation: Introduction: Reactive ion etching (RIE) has been employed in a wide range of fields such as semiconductor fabrication, MEMS (microelectromechanical systems), and refractive x-ray optics with a large investment put towards the development of deep RIE. Due to the intrinsic differing chemistries related to reactivity, ion bombardment, and passivation of materials, the development of recipes for new materials or material systems can require intense effort and resources. For silicon in particular, methods have been developed to provide reliable anisotropic profiles with good dimensional control and high aspect ratios1,2,3, high etch rates, and excellent material to mask etch selectivity...

36 MATERIALS SCIENCE↗

Full Multilayer Laue Lens for Focusing Hard X-rays

Multilayer Laue Lenses (MLLs) were developed by us using dynamic diffraction effects to efficiently focus hard x-rays to very small spots. Using a partial MLL we were able to focus 19.5-keV hard x-rays to a line focus of 16 nm with an efficiency of 31%. A full MLL is a complete linear MLL structure. It can be fabricated by bonding two partial MLL wafers, or by growing the full structure using magnetron sputtering without bonding. A 40-{mu}m full MLL, with a total of 5166 layers of WSi{sub 2} and Si, has been successfully grown by sputter deposition. The layer thicknesses gradually vary from 4 nm to {approx}400 nm and then back to 4 nm. Two coating runs were used to grow the full structure, one for each half. It took over 56 h for each run. A 100-{mu}m nearly-full MLL was constructed by bonding. Each 50-{mu}m half-structure has 1788 WSi{sub 2} and Si layers with 12-nm to {approx}32-nm thicknesses and {approx}32-{mu}m total thickness, followed by a thick WSi{sub 2} layer of {approx}17 {mu}m, and an AuSn layer of {approx}1 {mu}m. Both full MLL structures survived dicing and polishing. The primary results demonstrate the feasibility and potential of a full MLL with a doubled numerical aperture and large beam acceptance for hard x-rays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multilayer Laue lens : a path toward one nanometer x-ray focusing.

The multilayer Laue lens (MLL) is a novel diffractive optic for hard X-ray nanofocusing, which is fabricated by thin film deposition techniques and takes advantage of the dynamical diffraction effect to achieve a high numerical aperture and efficiency. It overcomes two difficulties encountered in diffractive optics fabrication for focusing hard X-rays: (1) small outmost zone width and (2) high aspect ratio. Here, we will give a review on types, modeling approaches, properties, fabrication, and characterization methods of MLL optics. We show that a full-wave dynamical diffraction theory has been developed to describe the dynamical diffraction property of the MLL and has been employed to design the optimal shapes for nanofocusing. We also show a 16 nm line focus obtained by a partial MLL and several characterization methods. Experimental results show a good agreement with the theoretical calculations. With the continuing development of MLL optics, we believe that an MLL-based hard x-ray microscope with true nanometer resolution is on the horizon.

47 OTHER INSTRUMENTATION↗

Metrology of multilayer Laue lens structures by means of scanning electron microscope imaging

Scanning electron microscope images obtained on a cross-section of a sputtered multilayer structure have proven to be crucial for qualifying these films for their intended use as a multilayer Laue lens. The quality of the linear Fresnel zone structure is assessed by means of image processing and analyses, and these analyses are then used to qualify the structure for further lens processing. The image analysis as well as problematic SEM artifacts are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The NSLS-II Multilayer Laue Lens Deposition System

The NSLS-II[1] program has a requirement for an unprecedented level of x-ray nanofocusing and has selected the wedged multilayer Laue lens[2,3] (MLL) as the optic of choice to meet this goal. In order to fabricate the MLL a deposition system is required that is capable of depositing depth-graded and laterally-graded multilayers with precise thickness control over many thousands of layers, with total film growth in one run up to 100m thick or greater. This machine design expounds on the positive features of a rotary deposition system[4] constructed previously for MLLs and will contain multiple stationary, horizontally-oriented magnetron sources where a transport will move a substrate back and forth in a linear fashion over shaped apertures at well-defined velocities to affect a multilayer coating.

43 PARTICLE ACCELERATORS↗