Detector thickness effects on nanosecond-gated imager response

Hybrid CMOS multi-frame imagers with exposure times down to ~2 ns have made significant impacts in high energy density physics and inertial confinement fusion research. The detector thickness is a key parameter in both detector quantum efficiency and temporal response. The Icarus hybrid CMOS imager has been fabricated with Si detector thicknesses of 8, 25, and 100 µm. The temporal response of imaging sensors with exposure time down to 2 ns has been examined and compared to directly measured photodiode current. The 100-μm thick variant displays extended features related to charge carrier collection and is more susceptible to field collapse. Here, we also demonstrate charge collection time effects on spatial response.

47 OTHER INSTRUMENTATION↗

X-ray characterization of the Icarus ultrafast x-ray imager

Ultrafast x-ray imagers developed at Sandia National Laboratories are a transformative diagnostic tool in inertial confinement fusion and high energy density physics experiments. The nanosecond time scales on which these devices operate are a regime with little precedent, and applicable characterization procedures are still developing. This paper presents pulsed x-ray characterization of the Icarus imager under a variety of illumination levels and timing modes. Results are presented for linearity of response, absolute sensitivity, variation of response with gate width, and image quality.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System

A non-invasive functional-brain-imaging system based on optically-pumped-magnetometers (OPM) is presented. The OPM-based magnetoencephalography (MEG) system features 20 OPM channels conforming to the subject’s scalp. We have conducted two MEG experiments on three subjects: assessment of somatosensory evoked magnetic field (SEF) and auditory evoked magnetic field (AEF) using our OPM-based MEG system and a commercial MEG system based on superconducting quantum interference devices (SQUIDs). We cross validated the robustness of our system by calculating the distance between the location of the equivalent current dipole (ECD) yielded by our OPM-based MEG system and the ECD location calculated by the commercial SQUID-based MEG system. We achieved sub-centimeter accuracy for both SEF and AEF responses in all three subjects. Due to the proximity (12 mm) of the OPM channels to the scalp, it is anticipated that future OPM-based MEG systems will offer enhanced spatial resolution as they will capture finer spatial features compared to traditional MEG systems employing SQUIDs.

60 APPLIED LIFE SCIENCES↗