Engineering PapersSearch

Engineering topics

Collins, S.

Publications and source records attributed to Collins, S..

1.1 eV GaInAs Cell Development for Dual-Use Solar and 1070 nm Laser Power Converters

Dual-use photovoltaic cells can receive solar and laser power simultaneously to generate current, an application relevant to space and terrestrial industries. This study investigates two concepts of solar cells optimized for dual-use 1070 nm laser and solar power conversion, a single-junction and triple-junction cell. The cell designs are based upon the 3- junction inverted metamorphic solar cell, previously shown highly efficient for solar conversion. Because it is closely bandgap-tuned for a 1070 nm laser, the 1 eV bottom junction is incorporated into each of the two designs, making its development key to the success of both concepts. However, each design requires some modification for efficient dual use. The single-junction device requires optimization to reduce short wavelength absorption of the broad solar spectrum. In both devices, the graded buffer layers in the GaInAs cell affect the cell's performance by reducing threading dislocations in the active junction. However, the buffer in the three-junction device also acts as a lateral transport layer and so affects the fill factor depending on its sheet resistance. By varying the buffer thickness, we demonstrate a direct relationship between buffer thickness and sheet resistance reduction, while considering implications to open-circuit voltages. We also performed resistance modeling to determine the optimal grid spacing and thickness of the grid fingers to minimize losses due to sheet resistance and grid shading. Efficiency data for a one junction GaInAs cell demonstrates a laser conversion efficiency of 38% at 1070 nm wavelength without an anti-reflection coating.

dual-use

1.1 eV GaInAs Cell Development for Dual-Use Solar and 1070 nm Laser Power Converters

Dual-use power converter cells can receive solar and laser power simultaneously to generate current, an application relevant to space and terrestrial industries. This study investigates two concepts of solar cells optimized for dual-use 1070 nm laser and solar power conversion, a single-junction and triple-junction cell. Because it is bandgap-tuned for a 1070 nm laser, the 1.1 eV junction is incorporated into each of the two designs, making its development key to the success of both concepts. Efficiency data for a one junction GaInAs cell demonstrates a laser conversion efficiency of 38% at 1070nm wavelength without an anti-reflection coating. However, the single-junction device requires optimization to reduce short wavelength absorption of the broad solar spectrum. In both devices, the graded buffer layers in the GaInAs cell affects the cell's performance by reducing threading dislocations in the active junction. However, the buffer in the three-junction device also acts as a lateral transport layer and so affects the fill factor depending on its sheet resistance. By varying the buffer thickness, we demonstrate a direct relationship between buffer thickness and sheet resistance reduction, while considering implications to open-circuit voltages. We also performed resistance modeling to determine the optimal grid spacing and thickness of the grid fingers to minimize losses due to sheet resistance and grid shading.

junctions

It's Time for Color Vision Deficiency Friendly Color Maps in the Radar Community

Color Vision Deficiency (CVD) is a decreased ability to discern between particular colors. 8% of men and 0.4% of women have some form of CVD. An informal poll of AGU and AMS twitter followers yielded 10% of 70 respondents self identifying as having CVD. When presenting data on a two-dimensional plane it is common to use colors to represent values, the mapping between values and colors is known as a colormap. Colormap choice is personal and is influenced by: (1) Ability to highlight scientifically interesting data. (2) Institutional choices (supervisor insists on a certain colormap). (3) Domain dominance of a particular colormap (common in the radar community). Colormap choice should be influenced by: (1) Ability to highlight scientifically interesting data. (2) Perceptual uniformity (thus not creating artificial structure). (3) Approachability by those with visual impairments (CVD). (4) Ideally, but not always achievable, reproducibility in greyscale.

Colormap

Transmittance Measurement of a Heliostat Facility used in the Preflight Radiometric Calibration of Earth-Observing Sensors

Ball Aerospace and Technologies Corporation in Boulder, Colorado, has developed a heliostat facility that will be used to determine the preflight radiometric calibration of Earth-observing sensors that operate in the solar-reflective regime. While automatically tracking the Sun, the heliostat directs the solar beam inside a thermal vacuum chamber, where the sensor under test resides. The main advantage to using the Sun as the illumination source for preflight radiometric calibration is because it will also be the source of illumination when the sensor is in flight. This minimizes errors in the pre- and post-launch calibration due to spectral mismatches. It also allows the instrument under test to operate at irradiance values similar to those on orbit. The Remote Sensing Group at the University of Arizona measured the transmittance of the heliostat facility using three methods, the first of which is a relative measurement made using a hyperspectral portable spectroradiometer and well-calibrated reference panel. The second method is also a relative measurement, and uses a 12-channel automated solar radiometer. The final method is an absolute measurement using a hyperspectral spectroradiometer and reference panel combination, where the spectroradiometer is calibrated on site using a solar-radiation-based calibration.

Czapla-Myers, J.

CheMin: A Definitive Mineralogy Instrument in the Analytical Laboratory of the Mars Science Laboratory

An important goal of the Mars Science Laboratory (MSL '09) mission is the determination of definitive mineralogy and chemical composition. CheMin is a miniature X-ray diffraction/X-ray fluorescence (XRD/XRF) instrument that has been chosen for the analytical laboratory of MSL. CheMin utilizes a miniature microfocus source cobalt X-ray tube, a transmission sample cell and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D X-ray diffraction patterns and X-ray fluorescence spectra from powdered or crushed samples. A diagrammatic view of the instrument is shown. Additional information is included in the original extended abstract.

Blake, David F.

Astrobiological Significance of Definitive Mineralogical Analysis of Martian Surface Samples Using the CheMin XRD/XRF Instrument

The search for evidence of habitability, or of extant or extinct life on Mars, will initially be a search for evidence of past or present conditions supportive of life. The three key requirements for the emergence of life are thought to be liquid water; a suitable energy source; and chemical building blocks. CheMin is a miniaturized XRD/XRF (X-Ray diffraction / X-ray fluorescence) instrument which has been developed for definitive mineralogic analysis of soils and rocks on the Martian surface. The CheMin instrument can provide information that is highly relevant to each of these habitability requirements as summarized below.

Feldman, S. M.

Definitive Mineralogical Analysis of Mars Analog Rocks Using the CheMin XRD/XRF Instrument

Mineral identification is a critical component of Mars Astrobiological missions. Chemical or elemental data alone are not definitive because a single elemental or chemical composition or even a single bonding type can represent a range of substances or mineral assemblages. Minerals are defined as unique structural and compositional phases that occur naturally. There are about 15,000 minerals that have been described on Earth, all uniquely identifiable via diffraction methods. There are likely many minerals yet undiscovered on Earth, and likewise on Mars. If an unknown phase is identified on Mars, it can be fully characterized by structural (X-ray Diffraction, XRD) and elemental analysis (X-ray Fluorescence, XRF) without recourse to other data because XRD relies on the principles of atomic arrangement for its determinations. XRD is the principal means of identification and characterization of minerals on Earth.

Blake, D. F.

Deep Space 1 flight experience: adventures on an ion drive (AAS 02-072)

This paper provides a brief overview of the DSI attitude control subsystem, shares a few lessons-learned, and describes some of the many daunting challenges faced by our tiny flight team during the course of the mission. Special focus will be given to the nuances of flying a spacecraft with ion propulsion, our nick-of-time rewrite of the attitude determination software after the failure of the on-board star tracker in late 1999, and DSl's subsequent successful flyby of comet Borrelly on September 22, 2001.

SEP ion propulsion DS1 flight experience

EMI Performance of the AIRS Cooler and Electronics

The TRW pulse tube cryocooler for JPL's Atmospheric Infrared Sounder (AIRS) instrument is required to meet stringent requirements for radiated electric and magnetic fields, conducted emissions on the input power bus, and electromagnetic susceptivility.

EMI AIRS Cooler Electronics Cryocooler

AIRS PFM Pulse Tube Cooler System-level Performance

JPL's Atmospheric Infrared Sounder (AIRS) instrument is being built to make precision measurements of air temperature over the surface of the Earth as a function of elevation; the flight instrument is in the final stages of assembly and checkout at this time, and uses a pair of TRW pulse tube cryocoolers operating at 55K to cool its sensitive IR focal plane.

AIRS PFM Pulse Tube Cooler System-level JPL's Atmo

Report of the x ray and gamma ray sensors panel

Overall five major areas of technology are recommended for development in order to meet the science requirements of the Astrotech 21 mission set. These are: detectors for high resolution gamma ray spectroscopy, cryogenic detectors for improved x ray spectral and spatial resolution, advanced x ray charge coupled devices (CCDs) for higher energy resolution and larger format, extension to higher energies, liquid and solid position sensitive detectors for improving stopping power in the energy range 5 to 500 keV and 0.2 to 2 MeV. Development plans designed to achieve the desired capabilities on the time scales required by the technology freeze dates have been recommended in each of these areas.

Szymkowiak, Andrew

Potential of CCDs for UV and X-ray plasma diagnostics

A program is under way to develop charge-coupled device (CCD) sensors for space-based X-ray astronomy imaging spectrometers. To date, laboratory line-emission spectra have been acquired throughout the range of 277 to 8000 eV (carbon through copper K-alpha emission) and CCD sensitivity has been demonstrated throughout the range of 1.1 through 8000 eV. Image resolution is excellent, limited almost entirely by the 15 micron pixel size. These results are presented and specialized techniques are described which permit such low energy response, high spectral resolution, and efficient charge collection. Finally, analysis is presented of one particular CCD characteristic which currently limits UV and X-ray performance: charge diffusion.

Janesick, J. R.

Nondispersive X-ray spectroscopy and imaging of plasmas using a charge-coupled device

A virtual-phase charge-coupled device (CCD) was used to obtain pinhole images and X-ray spectra of laser-produced, solid target plasmas. With the CCD used in the single-photon counting mode, the spectrum in the energy range 2-10 keV was obtained without a dispersive element. Typical spectra reveal two distinct temperatures: a cold component of approximately 200 eV and a hot component of approximately 5 keV. Also, multiline spectra comprising characteristic line emission (K alpha, K beta) from a multilayer target bombarded by beta-rays were recorded using a three-phase CCD. The results demonstrate the potential of CCDs as imaging spectrometers with application in space, laboratory, and fusion-plasma research.

Marsh, K.

The future scientific CCD

Since the first introduction of charge-coupled devices (CCDs) in 1970, CCDs have been considered for applications related to memories, logic circuits, and the detection of visible radiation. It is pointed out, however, that the mass market orientation of CCD development has left largely untapped the enormous potential of these devices for advanced scientific instrumentation. The present paper has, therefore, the objective to introduce the CCD characteristics to the scientific community, taking into account prospects for further improvement. Attention is given to evaluation criteria, a summary of current CCDs, CCD performance characteristics, absolute calibration tools, quantum efficiency, aspects of charge collection, charge transfer efficiency, read noise, and predictions regarding the characteristics of the next generation of silicon scientific CCD imagers.

Janesick, J. R.