Engineering Papers⌕ Search

Engineering topics

Coles, Garill

Publications and source records attributed to Coles, Garill.

Technical Specification Surveillance Interval Extension Using Self-Diagnostics

As part of the Light Water Reactor Sustainability program, an ongoing research effort is being conducted on technical specifications surveillance interval extension of digital equipment in nuclear power plants. The research team is led by Idaho National Laboratory and includes Pacific Northwest National Laboratory, Technology Resources, and Oak Ridge National Laboratory. This research focuses on developing methods for applying the U.S. Nuclear Regulatory Commission (NRC)–approved guidance to implement a licensee-controlled, risk-informed surveillance frequency change program in digital instrumentation and control (I&C) systems that include self-diagnostics and online monitoring (OLM) capabilities. Although approved methods exist for extending technical specifications (TS) surveillance test intervals (STIs) for general equipment, including analog I&C equipment, gaps remain in technology and guidance on crediting newer digital equipment’s internal self-diagnostics and OLM characteristics. Previous research described a general methodology for crediting internal self-diagnostics for extending surveillance test intervals. The methodology used self-diagnostics to detect—and credited recovery from—failure. Self-diagnostics were also applied for performance monitoring during the extended surveillance interval. This report discusses the status of recent activities to evaluate the previously developed methodology using a pilot study. Although both a utility partner for a pilot study and a specific digital asset were identified in FY2020, delays in obtaining proprietary information resulted in a limited ability to fully evaluate the methodology, and further interactions were complicated by the COVID pandemic. Therefore, at that time, the use of public-domain information—along with current processes for surveillance interval extension through a surveillance frequency control program—identified the need to fully assess diagnostic coverage as part of the pilot study. Furthermore, self-diagnostics were also identified as a potential option to replace the drift analyses conducted as part of current STI extension procedures. In FY2022, the project was reconstituted with the industry partner, and information and data were made available by the industry partner to the research team for review. The shared information included failure event descriptions and data for a digital I&C system since its implementation, as well as recent STI extension interval reports developed by the utility partner on that digital I&C system. This report presents an evaluation of this information and data and describes an application of the proposed methodology cited above. The methodology seeks to take advantage of the self-diagnostics and OLM capabilities to reduce risk or reduce the level of qualitative monitoring assessment needed to perform a risk-informed STI extension using existing NRC approved guidance or both. Addressing these issues of STI extension by crediting self-diagnostics is likely to result in benefits for current and future nuclear power plant (NPP) operations, including lowering the barriers to adoption of digital I&C systems and increasing cost savings by deferring or eliminating unneeded preventive maintenance (tasks or checks or activities). Specifically, self-diagnostic and OLM capabilities of newer digital equipment being installed in non-safety and safety applications are designed to detect failures, provide early warning of potential failures, and notify plant operators to take appropriate action to reduce out of service (OOS) time thus protecting safety margins. Moreover, the equipment is expected to provide information that time-related operational degradation is identified early to ensure timely and planned corrective actions instead of a reactive and unplanned approach ahead of an extended-surveillance interval.

42 ENGINEERING↗

Technical Specification Surveillance Interval Extension of Digital Equipment in Nuclear Power Plants: Review and Research. Light Water Reactor Sustainability Program report

The nuclear industry has been slow to incorporate digital technology into nuclear plant designs for several reasons, including: The high cost of design change modifications to implement them, versus simply replacing them with like for like technology when the components fail; Digital technology qualification issues, particularly in safety related applications that are susceptible to software common cause failure. This is a concern both for current operating plants as well as new builds; and, General familiarity and comfort with the existing analog technology on the part of the nuclear plant engineering staff, in spite of the superior performance and reduced maintenance costs of the digital replacements. At the same time, the nuclear industry is under significant cost pressure in the electric marketplace due to the abundance of natural gas generation and renewables. The industry would benefit by investment in new technologies that could lower future operating costs while addressing obsolescence and reliability issues of the current analog technologies. However, the industry has been unable to formulate the business cases to take advantage of these labor savings and production reliability improvements. This paper discusses another potential cost savings benefit of a transition to digital technology, extending the surveillance intervals of technical specification required equipment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗