Engineering Papers⌕ Search

Engineering topics

Coffey, T.

Publications and source records attributed to Coffey, T..

Chromatographic separation of radioactive noble gases from xenon

The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically contains trace amounts of the noble radioactive isotopes 85 Kr and 39 Ar that are not removed by the in situ gas purification system. The decays of these isotopes at concentrations typical of research-grade xenon would be a dominant background for a WIMP search exmperiment. To remove these impurities from the liquid xenon, a chromatographic separation system based on adsorption on activated charcoal was built. 400 kg of xenon was processed, reducing the average concentration of krypton from 130 ppb to 3.5 ppt as measured by a cold-trap assisted mass spectroscopy system. Finally, a 50 kg batch spiked to 0.001 g/g of krypton was processed twice and reduced to an upper limit of 0.2 ppt.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The LUX experiment

We present the status and prospects of the LUX experiment, which employs approximately 300 kg of two-phase xenon to search for WIMP dark matter interactions. The LUX detector was commissioned at the surface laboratory of the Sanford Underground Research Facility in Lead, SD, between December 2011 and February 2012 and the detector has been operating underground since January, 2013. These proceedings review the results of the commissioning run as well as the status of underground data-taking.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radon-related backgrounds in the LUX dark matter search

The LUX detector is currently in operation at the Davis Campus at the 4850’ level of the Sanford Underground Research Facility (SURF) in Lead, SD to directly search for WIMP dark matter. Knowing the type and rate of backgrounds is critical in a rare, low energy event search, and LUX was designed, constructed, and deployed to mitigate backgrounds, both internal and external. An important internal background are decays of radon and its daughters. These consist of alpha decays, which are easily tagged and are a tracer of certain backgrounds, and beta decays, some of which are not as readily tagged and present a background for the WIMP search. We report on studies of alpha decay and discuss implications for the WIMP search.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiogenic and muon-induced backgrounds in the LUX dark matter detector

The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is (2.6±0.2 stat ±0.4 sys ) ×10 -3 events keV$ ee\atop{-1}$ kg -1 day -1 in a 118 kg fiducial volume. The observed background rate is (3.6±0.4 stat )×10 -3 events keV$ ee\atop{-1}$ kg -1 day -1 , consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Results from the LUX Dark Matter Experiment at the Sanford Underground Research Facility

The Large Underground Xenon (LUX) experiment is a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota). The LUX cryostat was filled for the first time in the underground laboratory in February 2013. We report here results of the first WIMP search data set, taken during the period from April to August 2013, presenting the analysis of 85.3 live days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of 7.6 × 1 0 - 46 cm 2 at a WIMP mass of 33 GeV / c 2 . We find that the LUX data are in disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗