Engineering Papers⌕ Search

Engineering topics

Clifford, Corey

Publications and source records attributed to Clifford, Corey.

Impact of Flow Configurations on Response Time and Data Quality in Real-Time, In-Line Fourier Transform Infrared (FTIR) Monitoring of Viscous Flows

The real-time, in-line monitoring of continuous flow concentrations is widely conducted via infrared (IR) spectrometry by using a flow cell connected to a reactive flow stream. For protective purposes, the IR sensor tip is typically offset from the flow. This offset can cause the formation of a stagnant boundary layer above the sensor, especially when dealing with high-viscosity fluids. As a result, the IR signal response time is often controlled by the slow diffusional exchange of fluid in the boundary layer, as confirmed via 2D computational fluid dynamics (CFD) simulations. We evaluated several flow configuration modifications in a typical IR flow cell in order to identify the changes to the flow dynamics that enable improved response times with minimal changes to the cell configuration: the use of (i) vertical flow, where the standard horizontal flow over the sensor is redirected to contact vertically with the sensor, (ii) a static mixer to create radial flow momentum above the IR sensor, and (iii) horizontal or vertical nozzles to direct the flow toward the IR sensor. The vertical flow configuration did not show any significant improvement over the standard horizontal flow configuration. However, the static mixer, horizontal nozzle, and vertical nozzle configurations all resulted in markedly improved response times and signal quality, albeit at the expense of a higher pressure drop across the flow cell. These results point toward straightforward, user-accessible modifications of in-line IR flow cells that result in significant improvements in signal stability and acquisition times.

42 ENGINEERING↗

Separating Miscible Liquid–Liquid Mixtures Using Supported Ionic Liquid Membranes

Supported liquid membranes (SLMs) are promising in separating miscible liquid–liquid mixtures, which has been a key challenge in wastewater treatment and other applications. However, SLMs suffer from poor durability due to the loss of the liquid phase. In current work, ionic liquids (ILs) with high stability have been impregnated into polyvinylidene fluoride membranes to separate miscible benzene–heptane mixtures. The two imidazolium-based ILs, that is, 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF 6 ]) and 1-butyl-3-methylimidazolium tris(pentafluoroethyl) trifluorophosphate ([BMIM][FAP]), were tested in supported ionic liquid membranes (SILMs) for the benzene–heptane separation. Both ILs show successful separation within 48 h as indicated by nuclear magnetic resonance results. Compared to the SILM with [BMIM][FAP], the SILM with [BMIM][PF 6 ] has lower throughput and higher selectivity. The higher selectivity can be attributed to the higher hydrophilicity of [BMIM][PF 6 ], which results in strong repulsion against heptane. The lower throughput can be attributed to the higher hydrophilicity as well since it lowers the solubility of benzene in [BMIM][PF 6 ]. The stability of IL in SILMs has also been investigated via multiple separation cycles. The scanning electron microscopy, weight change of SILMs, and separation results indicate that the separation efficiency of the [BMIM][PF 6 ] SILM does not degrade for up to 144 h. The SILM has been further optimized with curvature design (i.e., curved SILM) to increase the interfacial area and thus increase the separation throughput, where the curved SILM separation device was 3D-printed. Here, the findings here have important implications on design and application of SILMs in separating miscible liquid–liquid mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗