Engineering Papers⌕ Search

Engineering topics

Clem, Paul

Publications and source records attributed to Clem, Paul.

Radioimaging for real-time tracking of high-voltage breakdown

Development of a radioimaging diagnostic for high-voltage component reliability testing and electrical breakdown computational model validation is described. Radioimaging has its roots in radio astronomy, where aperture synthesis (also known as synthesis imaging) has been utilized for decades to image radio sources far from Earth. Radioimaging as described herein, in contrast, seeks to image radio sources in close proximity to its receivers (i.e., in a laboratory environment). Here it is shown that corona discharge, a non-destructive precursor to catastrophic (thermal) arc discharge, electromagnetically radiates strongly within a 250 kHz – 2.5 GHz bandwidth, and is readily detected and located by postprocessing the received radio signals. The ability of radioimaging to detect both corona and arc discharge (grouped together herein as high voltage breakdown or HVB) makes it a valuable tool for 100% HVB detection in materials, components, and devices, and has the ability to indicate electrical weakness (via corona detection) prior to a destructive arc discharge event. Radioimaging enables HVB to be located both internal and external to dielectric components under test in near-real-time, with multiple and/or extended HVB events located simultaneously. In contrast, existing non-destructive diagnostics (at the time of this writing) either indicate electrical breakdown without resolving failure locations (e.g., current, voltage, and chemical measurements), locate external HVB (e.g., high-speed optical and ultraviolet (UV) measurements or photography), or locate both external and internal HVB but with low fidelity (e.g., a single HVB source can be located by existing time-of-arrival (TOA) UHF or acoustic emissions). Radioimaging instead creates a sequence of high-fidelity images similar to an optical high-speed camera but at radiofrequencies (RF), and is not limited to two-dimensions. Moreover, radioimaging has already served one internal and two external industry customers, the results of which are detailed in this report. The radioimaging results described herein were part of a three-year effort funded by the Sandia Lab Directed Research and Development (LDRD) program within the Radiation, Electromagnetic, High Energy Density Science (REHEDS) investment area.

47 OTHER INSTRUMENTATION↗

Impact of modifier-rich coatings on the ionic transport of glasses [Poster]

Ionic conduction in silicate glasses is mainly influenced by the nature, concentration, and mobility of the network-modifying (NWM) cations. The electrical conduction in SLS is dominated by the ionic migration of sodium moving from the anode to the cathode. An activation energy for this conduction process was calculated to be 0.82eV and in good agreement with values previously reported. The conduction process associated to the leakage current and relaxation peak in TSDC for HPFS is attributed to conduction between nonbridging oxygen hole centers (NBOHC). It is suggested that ≡Si-OH = ≡Si-O - + H 0 under thermo-electric poling, promoting hole or proton injection from the anode and responsible for the 1.5eV relaxation peak. No previous TSDC data have been found to corroborate this mechanism. The higher activation energy and lower current intensity for the coated HPFS might be attributed to a lower concentration of NBOHC after heat treatment (Si-OH + OH-Si = SiO-Si + H 2 O). This could explain the TSDC signal around room temperature for the coated HPFS. Another possible explanation could be a redox reaction at the anode region dominating the current response.

36 MATERIALS SCIENCE↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Low-Voltage Switchgear Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for low-voltage metal enclosed switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers experiments performed on two low-voltage switchgear units with each unit consisting of two vertical sections. The data collected supports characterization of the low-voltage HEAF hazard and these results will be used to support potential improvements in fire probabilistic risk assessment (PRA) methods. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 26 and Augsut 29, 2019 on nearidentical Westinghouse Type DS low-voltage metal-enclosed indoor switchgear. The threephase arcing fault was initiated on the aluminum main bus or in select cases on the copper bus stabs near the breaker. These experiments used either nominal 480 volts AC or 600 volts AC. Durations of the experiments ranged from approximately 0.4 s to 8.3 s with fault currents ranging from approximately 9.2 kA to 19.3 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. Environmental measurements of breakdown, conductivity and electromagnetics were also taken. The experiments were documented with normal and high-speed videography, infrared imaging and photography. The results, while limited, indicated the difficulty in maintaining and sustaining low-voltage arcs on aluminum components of sufficient duration and at a single point as observed operating experience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Open Box Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena. The experiments focus on providing data to better characterize the arc to improve the prediction of arc energy emitted during a HEAF event. An open box experiment allow for direct observation of the arc, which allows diagnostic instrumentation to record the phenomenological data needed for better characterization of the arc energy source term. The data collected supports characterization of the arc and arc jet, enclosure breach, material loss, and electrical properties. These results will be used to better characterizing the hazard for improvements in fire probabilistic risk assessment (PRA) realism. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA Labs. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 22, 2020 and September 18, 2020 on near-identical 51 cm (20 in) cube metal boxes suspended from a Unistrut support structure. The three-phase arcing fault was initiated at the ends of the conductors oriented vertically and located at the center of the box. Either aluminum or copper conductors were used for the conductors. The low-voltage experiments used 1 000 volts AC, while the medium-voltage experiments used 6 900 volts AC consistent with other recently completed experiments. Durations of the experiment ranged from 1 s to 5 s with fault currents ranging from 1 kA to 30 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. The experiments were documented with normal and high-speed videography, infrared imaging and photography.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on High Energy Arcing Fault Experiments

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for medium voltage electrical switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers four of the fourteen planned medium voltage electrical enclosure experiments. Subsequent reports will document the additional experiments performed in the future. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the United States Nuclear Regulatory Commission (NRC), the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setups and execution. The HEAF experiments were performed on four near-identical units of General Electric metal-clad medium voltage switchgear. The three-phase arcing fault was initiated on the primary cable connection bus. All four experiments used the same system voltage (6.9 kV) but varied the current and duration. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers and slug calorimeters at various locations around the electrical enclosures. Internal enclosure pressures were measured during the experiments. The experiments were documented with normal and high-speed videography, infrared imaging, and photography. Insights from the experimental series included timing information related to enclosure breach, event progression, mass loss measurements for electrodes and steel enclosures, peak pressure rise, particle analysis, along with visual and thermal imaging data to better understand and characterize the hazard. These results will be used in subsequent efforts to advance the state of knowledge related to HEAF.

42 ENGINEERING↗

Study of vacuum ultraviolet emission in helium and helium/nitrogen mixtures

Helium is frequently used as a working medium for the generation of plasmas and is capable of energetic photon emissions. These energetic photon emissions are often attributed to the formation of helium excimer and subsequent photon emission. When the plasma device is exposed to another gas, such as nitrogen, this energetic photon emission can cause photoionization and further ionization wave penetration into the additional gas. Often ignored are the helium resonance emissions that are assumed to be radiation trapped and therefore not pertinent to photoionization. Here, experimental evidence for the presence of helium atomic emission in a pulsed discharge at ten’s of Torr is shown. Simulations of a discharge in similar conditions agree with the experimental measurements. In this context, the role of atomic and molecular helium light emission on photoionization of molecular nitrogen in an ionization wave is studied using a kinetic modeling approach that accounts for radiation dynamics in a developing low-temperature plasma. Three different mixtures of helium at a total pressure of 250 Torr are studied in simulation. Photoionization of the nitrogen molecule by vacuum ultraviolet helium emission is used as the only seed source ahead of the ionization front. It is found that even though radiation trapped, the atomic helium emission lines are the significant source of photoionization of nitrogen. The significant effect of radiation trapped photon emission on ionization wave dynamics demonstrates the need to consider these radiation dynamics in plasma reactors where self-absorbed radiation is ignored.

42 ENGINEERING↗

Electromagnetic Pulse – Resilient Electric Grid for National Security: Research Program Executive Summary

Sandia National Laboratories sponsored a three-year internally funded Laboratory Directed Research and Development (LDRD) effort to investigate the vulnerabilities and mitigations of a high-altitude electromagnetic pulse (HEMP) on the electric power grid. The research was focused on understanding the vulnerabilities and potential mitigations for components and systems at the high voltage transmission level. Results from the research included a broad array of subtopics, covered in twenty-three reports and papers, and which are highlighted in this executive summary report. These subtopics include high altitude electromagnetic pulse (HEMP) characterization, HEMP coupling analysis, system-wide effects, and mitigating technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗