Engineering PapersSearch

Engineering topics

Clark, D. L.

Publications and source records attributed to Clark, D. L..

Acquisition and tracking performance measurements for a high speed area array detector system

A proof-of-concept (POC) demonstration system has been developed which demonstrates acquisition, tracking and point-ahead angle sensing for a space optical communications terminal utilizing a single high speed area array detector. The detector is the 128 x 128 pixel Kodak HS-40 photodiode array. It has 64 parallel readout channels and can operate at frames rates up to 40,000 frames/sec with rms readout noise of 20 photoelectrons. A windowing scheme and special purpose digital signal processing electronics are employed to implement acquisition and tracking algorithms. The system operates at greater than 1 kHz sample (frame) rates. Acquisition can be performed in as little as 30 milliseconds with less than 1 picowatt of 0.85 micron beacon power on the detector. At the same power level, the rms tracking accuracy is approximately 1/16 pixel. Results of system analysis and measurements using the POC system are presented.

Short, R. C.

Application of a single area array detector for acquistion, tracking and point-ahead in space optical communications

Functions of acquisition, tracking, and point-ahead in space optical communications are being combined into a single system utilizing an area array detector. An analysis is presented of the feasibility concept. The key parameters are: optical power less than 1 pW at 0.86 micrometer, acquisition in less than 30 seconds in an acquisition field of view (FOV) of 1 mrad, tracking with 0.5 microrad rms noise at 1000 Hz update rate, and point ahead transfer function precision of 0.25 microrad over a region of 150 microrad. Currently available array detectors were examined. The most demanding specifications are low output noise, a high detection efficiency, a large number of pixels, and frame rates over 1kHz. A proof of concept (POC) demonstration system is currently being built utilizing the Kodak HS-40 detector (a 128 x 128 photodiode array with a 64 channel CCD readout architecture which can be operated at frame rates as high as 40,000/sec). The POC system implements a windowing scheme and special purpose digital signal processing electronic for matched filter acquisition and tracking algorithms.

Clark, D. L.

Application of a single area array detector for acquisition, tracking and point-ahead in space optical communications

Functions of acquisition, tracking, and point-ahead in space optical communications are being combined into a single system utilizing an area array detector. An analysis is presented of the feasibility concept. The key parameters are: optical power less than 1 pW at 0.86 micrometer, acquisition in less than 30 seconds in an acquisition field of view (FOV) of 1 mrad, tracking with 0.5 microrad rms noise at 1000 Hz update rate, and point ahead transfer function precision of 0.25 microrad over a region of 150 microrad. Currently available array detectors were examined. The most demanding specifications are low output noise, a high detection efficiency, a large number of pixels, and frame rates over 1kHz. A proof of concept (POC) demonstration system is currently being built utilizing the Kodak HS-40 detector (a 128 x 128 photodiode array with a 64 channel CCD readout architecture which can be operated at frame rates as high as 40,000/sec). The POC system implements a windowing scheme and special purpose digital signal processing electronic for matched filter acquisition and tracking algorithms.

Clark, D. L.

Testing Long-Term Exposure To Vacuum

Facility for studying long-term effects of vacuum on materials described in report. Vacuum storage system maintains specimens at constant temperature and high vacuum. Enables specimens to be removed easily and safely for analysis. Nitrogen storage system maintains specimens at 77 degree F in pure, dry nitrogen gas under gauge pressure of 2 to 4 psi. Enables comparison of control specimens with specimens exposed to vacuum. Instrumentation-and-control system measures and records operating parameters and generates control signals and alarm indications as necessary.

Clark, D. L.

Conodont survival and low iridium abundances across the Permian-Triassic boundary in south China

The Permian-Triassic sedimentary sequence of China includes one of the most complete and fossiliferous Paleozoic-Mesozoic boundaries known. Closely spaced sampling across the boundary, which is an important extinction event for most organisms, has produced good conodont faunas that show little diversity change. A drop in conodont abundance is the only apparent response to the extinction event. A low concentration of iridium in the boundary clay (0.002 part per billion + or - 20 percent), as well as in samples immediately below and above, that range from 0.004 to 0.034 part per billion do not support the proposal of an extraterrestrial impact event at this boundary in China.

Clark, D. L.

Hypergravity effects on normal and avulsed developing avian radii

Rhode Island red female chicks were subjected to complete closed fracture of the right radius at 2 weeks post-hatching. The animals were allowed to heal for 1 week at either earth-gravity or 2-G-hypergravity state with control and estrogen-injected groups. Intact and fractured radial length, weight, average epiphysial-diaphysial diameters, and length, width, and weight of healing fracture callus were measured. Daily 2000 IU estrogen administration for 7 d increased intact radial length. Estrogen augments the effects of the 2-G state by inhibiting growth and depleting the mass of both intact and fractured radii and by decreasing the average distal epiphysial diameter of fractured bones. Animals exposed to the hypergravity state without hormonal treatment showed decreased fractured radial length, weight, and smaller proximal epiphysial diameters. The measurable parameters of the fracture callus (width, length, and weight) were depressed by the hypergravity state regardless of whether the animal was untreated or supplemented with estrogen.

Negulesco, J. A.

Effects of weightlessness on the development of the vestibular apparatus and ocular nystagmus in the rat

The chronic 2g centrifuge was constructed for testing weightlessness effects on development of vestibular apparatus and ocular nystagmus in the rat. Both the stationary and rotating rail tests were performed. A physiological review is presented on vestibular apparatus, along with a system analysis. Time constants and input threshold level of the system are also considered.

Clark, D. L.